AGN200A4H PANASONIC EW, AGN200A4H Datasheet

SIGNAL RELAY, DPDT, 4.5VDC, 1A, SMD

AGN200A4H

Manufacturer Part Number
AGN200A4H
Description
SIGNAL RELAY, DPDT, 4.5VDC, 1A, SMD
Manufacturer
PANASONIC EW
Datasheet

Specifications of AGN200A4H

Contact Configuration
DPDT
Contact Current Max
1A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
4.5V
Coil Type
DC, Monostable
Coil Current
31mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AGN200A4H
Manufacturer:
ELNA
Quantity:
20 000
Part Number:
AGN200A4HZ
Manufacturer:
YEONHO
Quantity:
9 613
Part Number:
AGN200A4HZ
Manufacturer:
NAIS
Quantity:
20 000
Company:
Part Number:
AGN200A4HZ
Quantity:
245 685
GN (AGN)
ORDERING INFORMATION
Contact arrangement
2: 2 Form C
Operating function
0: Single side stable
1: 1 coil latching
6: High sensitivity single side
Type of operation
0: Standard type (B.B.M.)
Terminal shape
Nil:
A:
S:
Nominal coil voltage (DC)
1H: 1.5V 03: 3V 4H: 4.5V 06: 6V 09: 9V
12: 12V 24: 24V
Packing style
Nil:
X:
Z:
Compliance with RoHS Directive
stable type
Standard PC board terminal
Surface-mount terminal A type
Surface-mount terminal S type
Tube packing
Tape and reel packing (picked from 1/2/3/4 pin side)
Tape and reel packing (picked from 5/6/7/8 pin side)
AGN 2
0
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
FEATURES
1. Compact slim body saves space
2. High sensitivity single side stable
3. Outstanding surge resistance.
4. The use of twin crossbar contacts
5. Increased packaging density
High Sensitivity of nominal
operating power 100mW is
Thanks to the small surface area of 5.7
mm
and low height of 9.0 mm
the packaging density can be
increased to allow for much smaller
designs.
type (Nominal operating power:
100mW) is available
Surge breakdown voltage between
contacts and coil:
2,500 V 2 10 s (Telcordia)
Surge breakdown voltage between
open contacts:
1,500 V 10 160 s (FCC part 68)
ensures high contact reliability.
AgPd contact is used because of its
good sulfide resistance. Adopting low-
gas molding material. Coil assembly
molding technology which avoids
generating volatile gas from coil.
Due to highly efficient magnetic circuit
design, leakage flux is reduced and
changes in electrical characteristics
from components being mounted
achived. Compact Slim
Body Saves space
10.6 mm
.224 inch
.354
.417 inch
inch,
6. Nominal operating power: 140 mW
7. Outstanding vibration and shock
8. Sealed construction allows
TYPICAL APPLICATIONS
1. Telephone switchboard
2. Telecommunications equipment
3. Security
4. Measurement equipment
5. Consumer electronic and audio
GN RELAYS (AGN)
close-together are minimized. This all
means a packaging density higher
than ever before.
resistance.
Functional shock resistance: 750 m/s
Destructive shock resistance:
1,000 m/s
Functional vibration resistance:
10 to 55 Hz (at double amplitude of
3.3 mm
Destructive vibration resistance:
10 to 55 Hz (at double amplitude of
5 mm
automatic washing.
visual equipment
.197
.130
2
inch)
inch)
TESTING
2

Related parts for AGN200A4H

AGN200A4H Summary of contents

Page 1

... Due to highly efficient magnetic circuit design, leakage flux is reduced and changes in electrical characteristics from components being mounted All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. GN RELAYS (AGN) close-together are minimized. This all means a packaging density higher than ever before. inch, 6 ...

Page 2

TYPES 1. Standard PC board terminal Nominal coil voltage 1. 4. 12V DC 24V DC Standard packing: Tube: 50 pcs.; Case: 1,000 pcs. 2. Surface-mount terminal 1) Tube packing Nominal coil voltage ...

Page 3

GN (AGN) 3) High sensitivity single side stable type Nominal coil Set voltage voltage ( 1. 4.5V DC 80%V or less of 10%V or more nominal voltage* nominal voltage* 9V ...

Page 4

Electrical life (1A 30V DC resistive load) Tested sample: AGN2004H, 6 pcs. Operating speed: 20 cpm Change of pick-up and drop-out voltage 100 90 80 Pick-up voltage Drop-out voltage ...

Page 5

... Please chuck the 80 dia. 3.150 dia. Avoid chucking the center of the relay. In addition, excessive chucking pressure to the pinpoint of the relay should be avoided. For general cautions for use, please refer to the “Cautions for use of Signal Relays” or “General Application Guidelines”. B portion. ...