Page 1
... Brightness detection for controlling the keypad backlight in mobile phones. 4. Brightness detection for surveillance cameras (night switching). Packing quantity: 3,000pcs. Part No. Picked from the 2/3-pin side AMS104W Remarks Non-condensing at low temperatures Non-condensing at low temperatures Remarks — ...
Page 2
Electrical characteristics (Ambient temperature: 25°C 77°F) Item Peak sensitivity wavelength — Minimum Photocurrent 1 Typical Maximum Minimum Photocurrent 2 Typical Maximum Photocurrent 3 Typical Dark current Maximum Rise time Typical Switching time Fall time Typical * Fluorescent lamp is ...
Page 3
Light Sensor (AMS1) 7. Switching time vs. resistive load characteristics Light source: White LED, Reverse voltage: 5V Resistive load voltage: 2.5V Ambient temperature 100 Rise time Fall time 10 1 0.1 0 100 Resistive ...
Page 4
CAUTIONS FOR USE 1. Applying stress that exceeds the absolute maximum rating If the voltage or current value for any of the terminals exceeds the absolute maximum rating, internal elements will deteriorate because of the excessive voltage or current. In ...
Page 5
... When picked from 1 and 4-pin side: Part No. AMS104Y (Shown above) (2) When picked from 2 and 3-pin side: Part No. AMS104W NaPiCa light sensor terminology Term Symbol Reverse voltage V Photocurrent Power dissipation P Operating temperature T ...
Page 6
Amplifier 1 Anode 2 Cathode TYPES Photocurrent 260 µA* Note 100 lx (Fluorescent lamp is used as light source) Tape package is the standard packing style. RATINGS 1. Absolute maximum ratings (Ambient temperature: 25°C 77°F) Item ...
Page 7
Light Sensor (AMS3) 3. Electrical characteristics (Ambient temperature: 25°C 77°F) Item Peak sensitivity wavelength — Minimum Photocurrent 1 Typical Maximum Minimum Photocurrent 2 Typical Maximum Photocurrent 3 Typical Dark current Maximum Rise time Typical Switching time Fall time Typical *1 ...
Page 8
Switching time vs. resistive load characteristics Light source: White LED, Reverse voltage: 2.5V Resistive load voltage: 2.5V Ambient temperature: 25°C 77°F 100 Rise time Fall time 10 1 0.1 0 100 Resistive load, kΩ DIMENSIONS All Rights ...
Page 9
Light Sensor (AMS3) SAFETY PRECAUTIONS Be sure to obey the following in order to prevent injuries and accidents. • Do not use the sensors under conditions that exceed the range of its specifications. It may cause overheating, smoke, or fire. ...
Page 10
Avoid using the sensor in environments containing excessive amounts of steam, dust, corrosive gas, or where organic solvents are present. 11. The following shows the packaging format Light sensor NaPiCa Through-hole type Light Sensor NaPiCa terminology Term Symbol Reverse ...