E52-THE6D-50/50C Omron, E52-THE6D-50/50C Datasheet

no-image

E52-THE6D-50/50C

Manufacturer Part Number
E52-THE6D-50/50C
Description
THERMISTOR SENSOR
Manufacturer
Omron
Series
E52r
Datasheet

Specifications of E52-THE6D-50/50C

Mounting Type
Free Hanging
Package / Case
Probe
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Resistance In Ohms @ 25°c
-
Resistance Tolerance
-
B Value Tolerance
-
B0/50
-
B25/50
-
B25/75
-
B25/85
-
B25/100
-
Operating Temperature
-
Power - Max
-
Lead Length
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E52THE6D5050C
A Wide Variety of High-precision
Temperature Sensors
• Ideal for the thermal input devices of Temperature Controllers.
• Select from a wide variety of Temperature Sensors according to
• General-purpose, low-cost, and exclusive models are available.
Ordering Information
■ List of Models
Note: 1. Exclusive models are provided on the following page.
General-
purpose
Models
Low-cost
Models
the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal.
Classifi-
Temperature Sensor
E52
cation
2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use.
3. The temperature range varies with the material, thickness, and construction of the protective tubing.
Refer to Safety Precautions for All Temperature
Controllers.
Sheathed
platinum
resistance
thermom-
eter
Standard
platinum
resistance
thermom-
eter
Sheathed
thermo-
couple
Standard
thermo-
couple
Low-cost
platinum
resistance
thermom-
eter
Low-cost
thermo-
couple
Descrip-
tion
E52-P@A
E52-P@C
E52-P@B
E52-P@C
E52-CA@A
E52-IC@A
E52-CA@B
E52-IC@B
E52-CA@C
E52-IC@C
E52-CA@B
E52-IC@B
E52-CA@C
E52-IC@C
E52-PR@C
E52-P10AE
E52-P6D
E52-P6F
E52-CA@AS
E52-IC@AS
E52-CA1D
E52-IC1D
E52-CA6F
E52-IC6F
E52-CA6D
E52-IC6D
E52-CA10AE
E52-IC10AE
Model and appearance
−200°C to
450°C
0°C to 450°C
0°C to
1,050°C
0°C to
1,000°C
0°C to
1,400°C
−50°C to
250°C
0°C to 400°C K (CA)
(See note 3.)
ture range
Tempera-
Pt100
K (CA)
J (IC)
R (PR)
Pt100
J (IC)
Element
type
3-conduc-
tor system
Non-
grounded
type
3-conduc-
tor system
Non-
grounded
type
Grounded
type
Non-
grounded
type
Conduc-
tor type
B
2 (0.75)
2 (0.25)
B
2 (0.75)
Class
SUS316
SUS316
SUS316
SUS310S
JIS ceramic
JIS special
ceramic
SUS304
Protective
material
tubing
CSM_E52_DS_E_6_2
Exposed
lead wires
Enclosed
terminals
Exposed
terminals
Enclosed
terminals
Exposed
lead wires
Exposed
terminals
Enclosed
terminals
Exposed
terminals
Enclosed
terminals
Enclosed
terminals
Exposed
lead wires
Terminal
type
5
6
6
7
9
13
13
14
15
16
17
18
19
21
Page
1

Related parts for E52-THE6D-50/50C

E52-THE6D-50/50C Summary of contents

Page 1

... E52-P10AE Models platinum E52-P6D resistance E52-P6F thermom- eter Low-cost E52-CA@AS thermo- E52-IC@AS couple E52-CA1D E52-IC1D E52-CA6F E52-IC6F E52-CA6D E52-IC6D E52-CA10AE E52-IC10AE Note: 1. Exclusive models are provided on the following page. 2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use. ...

Page 2

... E52-@@A-1 resistant model Silicone- E52-CA1D-40 covered lead wires Explosion- E52-@@C-6 proof mod- el Thermistors E52-THE5A E52-THE6F E52-THE6D Note: 1. General-purpose models and low-cost models are provided on the previous page. 2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use. ...

Page 3

... Compression Fitting PT screw Protective tubing Welding Terminal box Loose Flange Protective tubing Mounting screw Specification E52 Page 30 Note: The Compression Fitting is not of airtight construction. Do not use the Compression Fitting for applications in which the exposure of the sensing object will cause problems. Note: 1. Use the Loose Flange in normal atmospheric pressure ...

Page 4

... Vinyl-covered Sleeve: 0°C to 70°C NETU 0°C to 180°C Glass-wool-covered, Sleeve: 0°C to 100°C externally shielded Specify for E52-@@A model only. 6. Lead length (M) Specify the length in meters within the following range for the E52- @@A only: Range 100 m E52 Lead type 4 ...

Page 5

... E52-P20A D=3.2 E52-P20A D=3 E52-P20A D=3.2 E52-P20A D=3.2 NETU 4M NETU 8M E52-P35A D=3.2 E52-P35A D=3 E52-P35A D=3.2 E52-P35A D=3.2 NETU 4M NETU 8M E52-P20A D=4.8 E52-P20A D=4 E52-P20A D=4.8 E52-P20A D=4.8 NETU 4M NETU 8M E52-P35A D=4.8 E52-P35A D=4 E52-P35A D=4.8 E52-P35A D=4.8 NETU 4M NETU 8M E52-P50A D=4.8 E52-P50A D=4 ...

Page 6

... Custom-made models are available on request. Refer to page 4 for details D Terminal Protective type tubing length L (cm) Exposed- 20 terminal 35 Models 50 E52 4.8 dia. 6.4 dia. Model E52-P20C D=6.4 E52-P35C D=6.4 E52-P50C D=6.4 E52-P75C D=6.4 Protective tubing diameter D (mm) 8 dia. Model E52-P20B D=8 E52-P35B D=8 E52-P50B D=8 6 ...

Page 7

... Note: 1. The length centimeters, but “40” millimeters. Therefore, for the E52-P20C (cm), the protective tubing length L − 200 − 160 mm. 2. The length centimeters, but “50” millimeters. Therefore, for the E52-P75C (cm), the protective tubing length L − 750 − 700 mm. ...

Page 8

... Sleeve: 0°C to 70°C NETU 0°C to 150°C Glass-wool-covered with exter- Sleeve: 0°C to 100°C nal shield 6. Lead length (M) Specify the length in meters in the following range for the E52- @@A only. Range 100 m 7. Protective tubing material Code Protective tubing material --- ...

Page 9

... Lead Wire Length (M The sleeve resists temperatures ranging between −20°C and 70°C for standard models and 0°C and 100°C for heat-resistive models. K (CA) Model Information (E52-CA@A) Model Information Custom-made models are available on request. Refer to Model Number Legend on page 8 for details. ...

Page 10

... NETU 1M NETU 2M Standard E52-CA50A D=6.4 E52-CA50A D=6 Heat resistive E52-CA50A D=6.4 E52-CA50A D=6.4 NETU 1M NETU 2M Standard E52-CA20A D=8 1M E52-CA20A D=8 2M Heat resistive E52-CA20A D=8 E52-CA20A D=8 NETU 1M NETU 2M Standard E52-CA35A D=8 1M E52-CA35A D=8 2M Heat resistive E52-CA35A D=8 E52-CA35A D=8 NETU 1M NETU 2M ...

Page 11

... The sleeve resists temperatures ranging between −20°C and 70°C for standard models and 0°C and 100°C for heat-resistive models. J (IC) Model Information (E52-IC@A) Model Information Custom-made models are available on request. Refer to Model Number Legend on page 8 for details Terminal type ...

Page 12

... E52-IC35A D=3.2 E52-IC35A D=3 E52-IC35A D=3.2 E52-IC35A D=3.2 NETU 4M NETU 8M E52-IC50A D=3.2 E52-IC50A D=3 E52-IC50A D=3.2 E52-IC50A D=3.2 NETU 4M NETU 8M E52-IC20A D=4.8 E52-IC20A D=4 E52-IC20A D=4.8 E52-IC20A D=4.8 NETU 4M NETU 8M E52-IC35A D=4.8 E52-IC35A D=4 E52-IC35A D=4.8 E52-IC35A D=4.8 NETU 4M NETU 8M E52-IC50A D=4.8 E52-IC50A D=4 ...

Page 13

... Model E52-CA20B D=6.4 --- E52-CA35B D=6.4 E52-CA35B D=8 E52-CA50B D=6.4 E52-CA50B D=8 E52-CA75B D=6.4 E52-CA75B D=8 E52-IC20B D=6.4 --- E52-IC35B D=6.4 E52-IC35B D=8 E52-IC50B D=6.4 E52-IC50B D=8 E52-IC75B D=6.4 E52-IC75B D=8 Element wire K (CA) SUS316 J (IC) SUS316 650°C 750°C 750°C 750° ...

Page 14

... Element wire R 15 dia. 22 dia. Model E52-CA35B D=15 --- E52-CA50B D=15 E52-CA50B D=22 E52-CA75B D=15 E52-CA75B D=22 E52-CA100B D=15 E52-CA100B D=22 E52-IC35B D=15 --- E52-IC50B D=15 E52-IC50B D=22 E52-IC75B D=15 E52-IC75B D=22 E52-IC100B D=15 E52-IC100B D=22 14 ...

Page 15

... K (CA) SUS316 J (IC) SUS316 0 to 450° 500° 550° 600°C 15 dia. 22 dia. Model E52-CA35C D=15 --- E52-CA50C D=15 E52-CA50C D=22 E52-CA75C D=15 E52-CA75C D=22 E52-CA100C D=15 E52-CA100C D=22 E52-IC35C D=15 --- E52-IC50C D=15 E52-IC50C D=22 E52-IC75C D=15 --- E52-IC100C D=15 E52-IC100C D=22 15 ...

Page 16

... Note: The permissible temperature given for the protective tubing is higher than 1,400°C, but the permissible temperature of the thermocouple element wire is only 1,400°C. Therefore, the protective tubing of the E52-PR@C can withstand high temperatures momentarily to the levels given in the table as exceptions, but the element wire will deteriorate quickly if the thermocouple is used regularly at temperatures that exceed the permissible temperature for the element wire ...

Page 17

... Note: The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Model 1 E52-P6F 1M 2 E52-P6F 2M 4 E52-P6F 4M E52-P10AE Dimensions Silicone 3.2 dia. SUS304 (t0.25) Caulking shrinkable tubing Y-type crimp 30 terminal for M4 100 Note: 1. The protective tubing is of pipe construction, which must not be bent ...

Page 18

... E52-CA10AS 2M E52-CA10AS 4M E52-CA15AS 1M E52-CA15AS 2M E52-CA15AS 4M E52-CA20AS 1M E52-CA20AS 2M E52-CA20AS 4M E52 M 80 Red (+) White (−) Y-type crimp terminal for M4 L: Protective tubing length M: Lead wire length Element type: J (IC) Model E52-IC6AS 1M E52-IC6AS 2M E52-IC6AS 4M E52-IC10AS 1M E52-IC10AS 2M E52-IC10AS 4M E52-IC15AS 1M E52-IC15AS 2M E52-IC15AS 4M E52-IC20AS 1M E52-IC20AS 2M E52-IC20AS 4M 18 ...

Page 19

... Cut a thread into the workpiece, and screw in the thermocouple while pushing in so that the tip makes complete contact. End Workpiece Note: E52-CA1D with the same shape and multiple element wires are also available. Refer to page 27 for details. Protective tubing length (mm) Lead wire length (m) M6 screw ...

Page 20

... The tip is processed with solder, which ensures ease of welding. 3. The protective tubing is of pipe construction, which must not be bent. Lead wire Element type: K (CA) length (m) Model 1 E52-CA6D 1M E52-IC6D 1M 2 E52-CA6D 2M E52-IC6D 2M 4 E52-CA6D 4M E52-IC6D 4M Fully glass-wool-covered tubing with external dimensions of 3.6 × 2.2 (CA) and 3.8 × ...

Page 21

... Color code 105 (K: Blue, J: Yellow) M Lead wire length (M Lead wire Element type: K (CA) Element type: J (IC) length (m) Model E52-CA2GV 1M E52-IC2GV 1M E52-CA2GV 2M E52-IC2GV 2M White/red stripe (+) White (− Element type: J (IC) Adapter (provided (CA) J (IC) White/red stripe (+) White/red stripe (+) White/blue stripe (− ...

Page 22

... Class 2 (0.75) Thermal contact Grounded type Temperature 0°C to 300°C range Lead wire 0°C to 150°C Note: The E52-CA1GT is also available with double elements. Refer to page 23 for details. ■ Platinum Resistance Thermometers Platinum Resistance Thermometers for Surface Temperature Measurement Specifications Element type ...

Page 23

... Note: The lead wires are vinyl-covered, and cannot be used underwater. Use the E52- P5A-40 if waterproof lead wires are required for use underwater. Refer to page 24 for details. Lead wire length ( E52 M3 ...

Page 24

... Y-type crimp terminal for M4 Araldite resin Fixed with adhesive tape and silicone heat-shrinking tube d Sleeve Red (A) Lead wires White (B) Black (B) 2,000 60 Model Protective Sleeve tubing diameter diameter (mm) E52-P20A-1 D=4 4 E52-P20A E52-P20A E52-P5A-40 Dimensions FEP mold PFA-covered wire 7/0.18 7 dia ...

Page 25

... E52-CA75C-6 D=6.4 L2=700 75 E52-P@@C-6 Dimensions L 115 L2 L1 SUS316 15 dia. 6.4 dia. SUS304 77 Model Protective tubing length L (cm) E52-P20C-6 D=6.4 L2=150 20 E52-P35C-6 D=6.4 L2=300 35 E52-P50C-6 D=6.4 L2=450 50 E52-P75C-6 D=6.4 L2=700 75 E52 Hexagonal slot, 22 between flats 84 dia. 18 PF1/2 Protective L2 (mm) tubing diameter ...

Page 26

... Model Protective Sleeve tubing diameter diameter E52-CA20A-7 D=3 3 E52-CA20A-7 D=4 4 E52-CA20A-7 D=6 6 E52-CA20A-7 D=8 8 E52-P20A-7 Dimensions Y-type crimp terminal for M4 Red (A1) Lead wires Sleeve (SUS304) Caulking Black (B1) White (B1) Brown (A2) Yellow (B2) ...

Page 27

... Caulking SUS304 Thermo- couple Movable ring SUS304 screw element wire Model E52-CA1D- E52-CA1D- E52-CA1D- E52-CA1GT-14 Dimensions Silicone-covered M4, round, compensating cable with crimp terminal thirty 0.1-dia. conductors and external dimensions of 3.5 × 4.9 6.5 15 Lead wire length (M Model ...

Page 28

... This Thermistor is a dedicated Thermistor for the E5C2 and E5CS. Thermistor constant 3390K A pair of 0.12 dia. 7 Fluororesin-insulated stranded wires with 0.86 outer dia. each 3390K 3450K 4300K 5133K Flat glass-wool-shielded lead cable with 0.12 dia. 10 conductors and external dimensions of 2.5 × 1.55 Error E52 Lead wire 28 ...

Page 29

... E52-THE5A 50-150°C 1M E52-THE5A 100-200°C 1M E52-THE5A 150-300°C 1M Model E52-THE6D −50-50°C 1M E52-THE6D 0-100°C 1M E52-THE6D 50-150°C 1M E52-THE6D 100-200°C 1M E52-THE6D 150-300°C 1M Model E52-THE6F −50-50°C 1M E52-THE6F 0-100°C 1M E52-THE6F 50-150°C 1M E52-THE6F 100-200°C 1M E52-THE6F 150-300° ...

Page 30

... Retaining screw SUS304 Stan- Mini- dard mum diame- effec- ter tive posi- screw tion a length: (from f pipe end) 3.97 2.5 ±0.91 6.01 3.7 ±1.34 6.35 3.7 ±1.34 8.16 5.0 ±1.81 E52 Dimension d Flat diameter Part c Part 19 Protective tubing dia. D Head side ...

Page 31

... Use the Loose Flange at 400°C maximum not apply the Loose Flange to protective tubing diameters other than the applicable ones. Material: Aluminum MF-1 MF-2 120° 120° Three, 5 dia dia. 21 dia dia. D dia dia. 45 dia. 35 dia. 70 dia. E52 Three, 6.5 dia 6.6 31 ...

Page 32

... Silicone-covered 30/0.1 − Fully vinyl-covered 4/0.65 (waterproof) Fully glass-wool-cov- 7/0 150 ered Fully glass-wool-cov- ered with external shield of stainless steel E52 Model WPRG 2M WPRG 4M WPRG 8M WPRH 2M WPRH 4M WPRH 8M WPRH6 2M WPRH6 4M WPRH6 8M WCAG 2M WCAG 4M WCAG 8M WCAH 2M ...

Page 33

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords