G7L-1A-T 12VDC Omron, G7L-1A-T 12VDC Datasheet
G7L-1A-T 12VDC
Specifications of G7L-1A-T 12VDC
Related parts for G7L-1A-T 12VDC
G7L-1A-T 12VDC Summary of contents
Page 1
... DPST-NO Upper bracket SPST-NO DPST-NO Upper bracket SPST-NO (with test button) DPST-NO PCB mounting SPST-NO DPST-NO Note: 1. When ordering, add the rated coil voltage to the model number. Example: G7L-1A-T 12 VAC (~) Quick-connect terminals G7L-1A-T G7L-1A-B G7L-2A-T G7L-2A-B G7L-1A-TJ G7L-1A-BJ G7L-2A-TJ G7L-2A-BJ G7L-1A-TUB ...
Page 2
... Screw terminals SPST-NO G7L-1A-B G7L-1A-BJ DPST-NO G7L-2A-B G7L-2A-BJ Applicable Relay G7L-1A-T/G7L-1A-TJ/G7L-1A-B/G7L-1A-BJ G7L-2A-T/G7L-2A-TJ/G7L-2A-B/G7L-2A-BJ G7L-1A-T/G7L-1A-TJ/G7L-2A-T/G7L-2A-TJ G7L-1A-B/G7L-1A-BJ/G7L-1A-BUB/G7L-1A-BUBJ G7L-2A-B/G7L-2A-BJ/G7L-2A-BUB/G7L-2A-BUBJ Model Number Legend G7L - - Contact Form 1A: SPST-NO 2A: DPST-NO 2. Terminal Shape T: Quick-connect terminals P: PCB terminals B: Screw terminals Application Examples ! Compressors for air conditioners and heater switching controllers. ...
Page 3
... A, 220 VAC 25 A, 220 VAC (~) (~) 5,500 VAC (~) 5,500 VAC (~) Max. voltage Power voltage consumption (approx.) 110% of rated 1 voltage lt ( (60 Hz) 132 V 264 v 110% of rated 1 voltage lt G7L-1A-P/G7L-2A-P Resistive load Inductive load (cos (cos 220 VAC (~) 4,400 VAC (~) G7L 3 ...
Page 4
... Destruction: 1,000 m/s 2 Malfunction: 100 m/s Mechanical: 1,000,000 operations min. (at 1,800 operations/hr) Electrical: 100,000 operations min. (at 1,800 operations/hr under rated load) Operating: --25#C to 60#C (with no icing) Operating: 35% to 85% Quick-connect terminal models: approx PCB terminal models: approx. 100 g Screw terminal models: approx. 120 g G7L ...
Page 5
... G7L-2A-Bj G7L-1A-P SPST-NO G7L-2A-P DPST-NO TÜV: File No. R9051158 (VDE 0435, IEC 255, IEC 950, EN60950) Model Contact Form G7L-1A-Bj SPST-NO G7L-2A-Bj DPST-NO G7L-1A-Tj SPST-NO G7L-2A-Tj DPST-NO G7L-1A-P SPST-NO G7L-2A-P DPST-NO Coil ratings Contact ratings 12 to 240 VAC 30 A, 277 VAC (RES) ...
Page 6
... Life Expectancy Life Expectancy 220 VAC resistive load 220 VAC inductive load (cos% = 0.4) Switching current (A) 220 VAC resistive load 220 VAC inductive load (cos% = 0.4) Switching current (A) 220 VAC resistive load 220 VAC inductive load (cos% = 0.4) Switching current (A) G7L ...
Page 7
... G7L-2A-TJ with Test Button Quick-connect Terminals with DIN Track Mounting Adapter Note: 1. The DIN Track Mounting Adapter and DIN tracks are sold separately. 2. The DIN Track Mounting Adapter can be track-mounted or screw-mounted. G7L-1A-T PFP-jN 55.5 max. Terminal Arrangement/ Internal Connections (Top View) ...
Page 8
... Terminal Arrangement/ P7LF-D Internal Connections G7L (Top View) 51.5 max. 63 max. 5 66.5 max. P7LF-D G7L 51.5 max max. 5 66.5 max. P7LF-D G7L 51.5 max max. 5 66.5 max. Terminal Arrangement/ P7LF-06 G7L Internal Connections (Top View) 51.5 max. 61.5 max max. P7LF-06 G7L 51 ...
Page 9
... Test Button 55.5 max. Four, M4 screws for contact Quick-connect Terminals with Upper Bracket G7L-1A-TUB G7L-2A-TUB G7L-1A-TUBJ with Test Button P7LF-06 Terminal Arrangement/ G7L Internal Connections (Top View) 51.5 max. 2 61.5 max max. P7LF-06 G7L 51.5 max. 2 61.5 max. ...
Page 10
... G7L-1A-B Two, M3.5 screws for coil G7L-2A-B Two, M3.5 screws for coil G7L-1A-BJ with Test Button Two, M3.5 screws for coil G7L-2A-BJ with Test Button Two, M3.5 screws for coil 10 Terminal Arrangement/ Mounting Holes Internal Connections (Top View) Two, 4.5-dia. hole or ...
Page 11
... Screw Terminals with Upper Bracket G7L-1A-BUB Two, M3.5 screws for coil P7LF-D Terminal Arrangement/ G7L Internal Connections (Top View) 51.5 max. 65.5 max max. P7LF-D G7L 51.5 max 65.5 max max. P7LF-D G7L 51.5 max. 2 65.5 max max. P7LF-D G7L 51 ...
Page 12
... Test Button Two, M3.5 screws for coil G7L-2A-BUBJ with Test Button Two, M3.5 screws for coil PCB Terminals with PCB Mounting G7L-1A-P G7L-2A-P 12 Four, M4 screws for contact Mounting Holes Terminal Arrangement/ Internal Connections Two, 4.5-dia. hole (Top View tapped holes ...
Page 13
... AC Operating Coil Mounting Holes (Bottom View) Two 4.5-dia. holes 3 40$0.1 Mounting Holes (Bottom View) Two 51.5 max. 4.5-dia. holes 40$0.1 14.5 5 Mounting Holes (Bottom View) Two 51.5 max. 4.5-dia. holes 40$0 G7L 13 ...
Page 14
... G7L Relays. Cut and shorten the track to an appropriate length it if the required track length is less than 50 cm. ! The DIN Track Mounting Adapter and Front-connecting Socket can be mounted on the G7L with just one hand and dismounted Front-connecting with ease by using a screwdriver. Socket ! ...