144SC0811-BARO SENSORTECHNICS, 144SC0811-BARO Datasheet

PRESSURE SENSOR

144SC0811-BARO

Manufacturer Part Number
144SC0811-BARO
Description
PRESSURE SENSOR
Manufacturer
SENSORTECHNICS
Datasheet

Specifications of 144SC0811-BARO

Sensor Output
Voltage
External Depth
60mm
Voltage Rating
24V
Port Style
Tube
Pressure Measurement Type
Barometric
Length/height, External
32mm
Response Time
1ms
Sensing Accuracy
0.1%
External Width
30mm
FEATURES
SERVICE
SPECIFICATIONS
Maximum ratings
January 2005 / 005
· 0...70 mbar to 0...10 bar,
· Barometric pressure ranges
· 0...5 V output
· Internal supply regulation
· Precision temperature compensated
Non-corrosive, non-ionic working fluids,
such as dry air and dry gases.
Supply voltage
Maximum load current
Temperature limits
Lead temperature (10 sec soldering)
Humidity limits
Proof pressure
0...1 to 0...150 psi,
absolute, gage or differential pressure
(custom calibrations available)
and calibrated
source
sink
Storage
Operating
Compensated
pressure inlets only
144SM...
144SB010...
144SC...BARO
144SU01..., 144SU05...
144SU150...
all others
144SC...BARO
all others
1
Signal conditioned precision pressure transducers
2x rated pressure
0 - 100 %RH
-55 to 100°C
-40 to 85°C
-10 to 60°C
0 to 70 °C
7.5...24 V
250 psi
1.4 bar
20 mA
10 mA
16 bar
300°C
20 psi
2 bar
ELECTRICAL CONNECTION
Scale:
144S...-
PCB
144S...-PCB Series
www.sensortechnics.com
1 cm
1 inch
+Vs
Vout
-Vs
7.5 V to 24 V
V
1/5

Related parts for 144SC0811-BARO

144SC0811-BARO Summary of contents

Page 1

... January 2005 / 005 Signal conditioned precision pressure transducers Scale: ELECTRICAL CONNECTION 7.5... -55 to 100°C -40 to 85°C 144S...- -10 to 60° °C 300° 100 %RH 1.4 bar 16 bar 2 bar 20 psi 250 psi 2x rated pressure 144S...-PCB Series inch +Vs 7 Vout PCB -Vs www.sensortechnics.com V 1/5 ...

Page 2

... Series Signal conditioned precision pressure transducers PERFORMANCE CHARACTERISTICS STANDARD DEVICES (unless otherwise noted ° 2/5 > 100 25°C) L amb January 2005 / 005 www.sensortechnics.com ...

Page 3

... The output signal can be adjusted to sea level reading by turning the offset trimmer. 9. Thermal effects refer to the combined effects of offset and sensitivity shifts, this is true from -10 to 60°C relative to 25°C. January 2005 / 005 Signal conditioned precision pressure transducers > 100 25°C) L amb 144S...-PCB Series www.sensortechnics.com ° 3/5 ...

Page 4

... Barometric versions Vout 100% 2 Port B high pressure port 32.0 14.0 9.1 span adjust 3 Port A NOM 6 800 900 1000 1100 mbar terminals 0.56 diam. +Vs -Vs Vout 12.6 January 2005 / 005 www.sensortechnics.com 16 psia dimensions mm ...

Page 5

... Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. January 2005 / 005 ...

Related keywords