MIC+340/IU/TC MICROSONIC, MIC+340/IU/TC Datasheet

no-image

MIC+340/IU/TC

Manufacturer Part Number
MIC+340/IU/TC
Description
ULTRASONIC, M30, 5M RNG, ANALOG O/P
Manufacturer
MICROSONIC
Datasheet

Specifications of MIC+340/IU/TC

Sensing Range
350 - 3400mm
Frequency
120Hz
Operating Temperature Range
-25°C To +70°C
Sensing Range Distance
3400mm
Sensing Range Max
5000mm
Sensor Input
Ultrasonic
Supply Voltage Dc
RoHS Compliant
mic+340/IU/TC / microsonic
mic+340/IU/TC
housing
operating range
design
operating mode
ultrasonic -specific
means of measurement
transducer frequency
blind zone
operating range
maximum range
angle of beam spread
resolution/sampling rate
reproducibility
accuracy
electrical data
operating voltage U
voltage ripple
no-load current consumption
type of connection
outputs
output 1
Balluff Sales: 0161 282 4700
g
f
e
d
c
mark for sensor comparison
1 x analogue 4-20 mA + 0-10 V5,000 mm
detection zone
B
Page 1 of 2
350 - 3,400 mm
cylindrical M30
analogue distance measurements
echo propagation time
120 kHz
350 mm
3,400 mm
5,000 mm
please see graphics detection zone
0.18 mm
± 0.15 %
9 - 30 V d.c., reverse polarity protection
± 10 %
5-pin M12 initiator plug
analogue output
current: 4-20 mA / voltage: 0-10 V (at U
2 % (temperature drift internal compensation)
80 mA
B
15 V), short-circuit-
Seite 1 von 3
05.10.2009