Page 1
... SP 400 PRODUCT DESCRIPTION The SP 400 features a 200mV d.c. measurement range with auto-zero and auto-polarity. Decimal points are user selectable. 400 features a negative rail generator which enables the meter to measure a signal referenced to its own power supply GND. backlighting ensures excellent readability under low light conditions. The module is easily fitted into the panel, using the fixing clip provided ...
Page 2
... SP 400 DIMENSIONS All dimensions in mm (inches) PANEL FITTING 1 FUNCTIONAL BLOCK DIAGRAM 3½ Digit Backlit LCD Voltmeter Module anel thickness: 1.0 - 3.0 (0.04 - 0.12) 2 PIN CONFIGURATION 1 8 www.lascarelectronics.com a. 0.75 (0.03) b. 10.00 (0.39) c. 6.00 (0.24 (rear view) LBAT LCOM CAL ' No: 695 - Page ...
Page 3
... SP 400 CIRCUIT DIAGRAM PIN FUNCTIONS 1. V+ Positive power supply to the meter. 2. GND 0V power supply to the meter (3.0 to 7.5V meter power supply applications only). 3. BL- Connect to the meter's negative supply voltage to switch on the LED backlighting. For meter supply voltages above 5V, add a series resistor Rs. ...
Page 4
... Digit Backlit LCD Voltmeter Module +3.0 to +7. INH 3 ±200mV BL INL GND 2 +6.0 to +15. INH 3 ±200mV BL INL 400 Issue 7 Janury/2007 www.lascarelectronics.com 400 5 - +3.0 to +7. INH 5 I- INL GND +6.0 to +15. INH + 5 I- INL M.C. Applies to P 400/3 No: 695 - Page ...