3400-0000 REDINGTON COUNTERS, 3400-0000 Datasheet

no-image

3400-0000

Manufacturer Part Number
3400-0000
Description
LCD Counter
Manufacturer
REDINGTON COUNTERS
Datasheet

Specifications of 3400-0000

Supply Voltage Max
300V
Time Range Max
0.1s
Character Size
7mm
Time Range Min
99999999h
No. Of Digits / Alpha
8
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Description
The Redington Model 34 LCD Totalizer/Preset Counter provides a large display, with 0.28” [7mm] high characters, in industry size housings. The Model
34 counts and displays the number of pulses that appear at its input terminal at a rate of 40 pulses per second (Hz). The input interface handles AC or
DC inputs. The Totalizers are available in 7 different housings. All models are totally sealed and are capable of submersion in 6’ [2 meters] of water. A
wide operating voltage, 10-300VDC and 20-300VAC, makes the model 34 versatile for all indoor and outdoor applications. All models are NEMA 4/4X,
12, & IP66 rated when used with the optional gasket and have a polarized lens which assures high visibility in an outdoor environment.
Maintenance Meters are offered with a maximum of 3 preset “Redi-Alert’s” icons to alert users when service intervals are due or other periodic timed
events are due. Models are available with front panel field or factory programmable alerts. Not only does the display flash to get attention, but it displays
a choice of 7 different .08” [2mm] maintenance icons. Models are available with an Open Drain MOSFET output for the actuation of external alarms or
indicator lamps. Users can program or specify the count/service interval and flash duration for each Redi-Alert. Flash duration is the amount of time in
hours that the specific icon flashes before and after the specified total count. If a front panel manual reset of the Redi-Alert is required, the front panel
models with switches must be specified.
Features
Specifications
Display:
Annunciators:
Reset:
Accuracy:
Displays:
Maximum pulse rate:
Inputs:
Power:
Terminations:
Output:
8
Totally sealed from moisture and dirt
AC or DC voltage input in the same unit
Compact depth
Programmable output thresholds
Preset count value
Up to 3 Redi-Alerts/7 icons
Model 34
Format: Open-Drain MOSFET with Source connected to
Common (see note 3)
Maximum Withstanding voltage: 30VDC, reference to Common
Maximum Load current: 0.1Amp
LCD with large 0.28” [7mm] high figures black on
light background
LCD 0.08” [2mm]
Remote, manual and non-reset
100% [provided signal meets stated parameters]
8 digits (99999999)
40 pulses per second (Hz)
10-300VDC and 20-300VAC - 50/60Hz
VIH 20VAC or 10VDC minimum
VIL 3VAC or 3VDC maximum
Self powered - battery life 15+ years
Standard 0.250” [6.4mm] spades
www.redingtoncounters.com
Electronic
Environmental:
Sealing:
EMC Compliance:
Enclosure:
Approvals:
Weight:
Temperature: (Storage and Operating) -40 to +185˚F [-40 to +85˚C]
Humidity:
Vibration:
Shock:
Dielectric:
Compliance: Compliant to the European WEEE and RoHS Directives
Fits in existing panel openings
Always on display
A choice of 7 housings
A choice of reset modes
Front panel programmable
Preset Counter with output
15+ Year Battery Life
95% RH per SAE J1378
20g @ 10 to 80 Hz per SAE J1378
44 to 55g’s per SAE J1378
1000VAC 50/60 Hz for 1 minute
Totally sealed
EN61326:1997 with A1:1998 and A2:2001 for
industrial environments
Totally sealed from moisture and dirt, NEMA
4/4X, 12, & IP66 compliant from the front when
properly mounted using the optional gasket.
(Not applicable to Snap-In Model)
UL and cUL Recognized (file # ELIY2.E36690),
CE, SAE, NEMA 4/4X/IP66 compliant
1oz [28g]
LCD Counter

Related parts for 3400-0000

3400-0000 Summary of contents

Page 1

Model 34 Description The Redington Model 34 LCD Totalizer/Preset Counter provides a large display, with 0.28” [7mm] high characters, in industry size housings. The Model 34 counts and displays the number of pulses that appear at its input terminal at ...

Page 2

Model 34 Functions Preset Counter: The preset function is centered on the output signal. When the count reaches the preset value, the output signal is turned “on”. The Preset function is count “up”. In addition to the preset function, models ...

Page 3

Model 34 3-Hole Mount 1.29 [32.7] .28 [7.0] .79 [20.0] 2.87 [72.9] .75 [19.0] .25 [6.3] .88 [22.3] 1.43 [36.3] Panel Cutout: 1.45” [36.8mm] x 0.95” [24.1mm] Square Flush Mount .28 [7.0] .79 [20.0] 1.89 [48.0] 1.29 [32.7] 1.89 [48.0] ...