18D-1-50 PAYNE ENGINEERING, 18D-1-50 Datasheet

Variable Transformer

18D-1-50

Manufacturer Part Number
18D-1-50
Description
Variable Transformer
Manufacturer
PAYNE ENGINEERING
Datasheet

Specifications of 18D-1-50

Power Supply Output Type
Variable
No. Of Outputs
1
Output Voltage
118V
Power Rating
5.9kVA
Length
203mm
Width
305mm
Height
356mm
Transformer Mounting
Panel
Secondary Current Nom
50A
External Depth
6.0"
External Height
12.00"
External Width
5.5"
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Rt. 29 Scott Depot WV 25560-0070
Description:Phase-Angle SCR
Power Controls
Product Range: 120 to 600 VAC,
Single- or Three-Phase, 10 to
1200 amps
Application: C onstant Resistance
Loads
All Solid State Construction
Exclusive “2 Millisecond” Fuses
for Short-Circuit Protection
Exclusive “V
sient Voltage Protection
Exclusive Full Rated Operation in
50
Fans Through 450 Amps
Exclusive Proprietary Heatsinks
Silent, Arcless Switching
Infinitely Variable Voltage Control
Open-Chassis or Enclosed
Full Range of Control Options
and Accessories
Replace Variable Transformers
Electric Furnaces and Ovens
Heat Sealing and Packaging
Ink Drying
Foam Cutting
Plastic Extruding and Molding
Process Heating
Food Processing Ovens
Autoclaves
TYPICAL APPLICATIONS
o
C (122
MODEL 18D/E
FEATURES
o
F) Ambients Without
bo
Clamping” Tran-
Model 18D/E SCR controls provide
infinitely variable control of sin-
gle-phase (18D) and three-phase
(18E) a.c. voltages to resistive heat-
ing elements. These units are solid
state replacements for variable
transformers, saturable core reac-
tors, electromechanical contactors,
and mercury relays. Power semi-
conductors replace contacts and
brushes to switch electric power
without moving parts, and, when op-
erated within stated ratings for cur-
rent, voltage, and temperature,
have no known MTBF or life
expectency rating.
18D/E SCR controls incorporate ex-
clusive design features to protect
the power semiconductor compo-
nents against damage:
1> Unique “V
unmatched protection for power
semiconductors against transient
voltage spikes common on indus-
trial power mains.
2> “2 millisecond” fuses protect
semiconductors against short-cir-
cuit faults. Payne Engineering SCR
controls are the only power controls
in the industry equipped with factory
tested and approved fuses coordi-
nated with power semiconductors.
3> Proprietary heatsinks are engi-
neered in-house coordinating finite
element analysis (FEA) with on-site
lab tests. Payne Engineering SCR
controls operate at 50
ambient temperatures with no derat-
ing.
Standard configuration of all 18D/E
controls is for manual control via a
270
Standard options allow for open- or
closed-loop automatic control in re-
sponse to an analog control signal
from a temperature controller, PLC
I/O module, or other external
source. Other options allow controls
APPLICATION FLEXIBILITY
Three Pillars Of Protection
INNOVATIVE ADVANCED
o
turn potentiometer (included).
TECHNOLOGY:
bo
Clamping” provides
o
C (122
o
F)
APPLICATION ASSISTANCE - 304/757-7354
to be configured for the specific re-
quirements of each application.
Power Circuit: inverse-parallel
semiconductors selected for V
Clamping transient protection, with
parallel R-C circuit for dv/dt protec-
tion. Current-clamping 2-millisec-
ond power fuses in series with
power semiconductors provide
short-circuit protection.
Control Circuit:all solid state cir-
cuitry supplies synchronized gate
pulses to each thyristor via isolating
pulse transformer.
Mains Frequency: 50, 60 Hz
stan-dard. Other frequencies avail-
able as special order (consult fac-
tory).
Output Voltage:0 to nominal input
voltage, infinitely variable.
Overall Efficiency: 98.5 to 99.5%.
Power Loss: approximately 1-2
watts/ampere/switched pole.
Voltage Drop Across Power Circuit
at 100% Output:1-2 volts maximum
per switched pole.
Proof Voltage:(isolation between
power circuit, control circuit and
ground) greater than 2 kV.
Control Input:manual control via
75K Ohm, 2 watt potentiometer with
integral On/Off switch and indicating
dial plate standard.
Control Power:5 watts maximum.
Derived from 12 VA isolation control
transformer (except for 120 VAC
18D units in 10, 20, 30 amp sizes).
Fuse Protection:2 millisecond I
fuses are factory tested and coordi-
nated with all power semiconduc-
tors, considering:
Transient Voltage Protection: volt-
age breakover (V
R-C filters for dv/dt protection.
Ambient Temperature Range: -10 to
+50
a. fuse element melt time t
b. peak melt current I
c. arc quench time t
d. peak arc current I
o
C (122
SCR Power Controls
SPECIFICATIONS
24 HOUR FAX - 304/757-7305
o
F).
bo
Model 18D/E
) protection with
arc;
arc
melt
.
;
melt
;
bo
2
t

Related parts for 18D-1-50

18D-1-50 Summary of contents

Page 1

... On/Off switch and indicating dial plate standard. Control Power:5 watts maximum. Derived from 12 VA isolation control transformer (except for 120 VAC 18D units in 10, 20, 30 amp sizes). 2 Fuse Protection:2 millisecond I fuses are factory tested and coordi- nated with all power semiconduc- tors, considering: a ...

Page 2

... Isolated Chassis Construction: electrically isolated chassis avail- able through 80 amp size. Note: 18D controls with “i” suffix in model num- ber include isolated chassis con- struction as standard feature. Thermistor Control: control accepts ...

Page 3

... Max.Rated Fuse Number (Fuse) Voltage Number Single-Phase, 120 VAC, 50/60 Hz Input, 0-118 VAC Output 18D-1-10i 10 1.2 49B25-10 18D-1-20i 20 2.4 49B25-20 18D-1-30i 30 3.6 49B25-30 18D-1-50 50 5.9 49A50-50 18D-1-80 80 9.4 49A50-80 18D-1-120 120 14.1 49A50-125 18D-1-150 150 17.7 49A50-150 18D-1-250 250 30.0 49A50-250 ...

Page 4

... 90 (2286) 36 (915) 20 (508) 14 (356) 12 (305) 8 (203) 14 (356) 12 (305) 8 (203) 20 (508) 16 (407) 9 (229) 20 (508) 16 (407) 9 (229) 24 (610) 16 (407) 9 (229) 30 (762) 20 (508) 9 (229) 36 (915) 24 (610) 10 (254) 36 (915) 24 (610) 10 (254) 42 (1067) 30 (762) 12 (305) 42 (1067) 36 (915) 12 (305) 48 (1220) 36 (915) 12 (305) 90 (2286) 36 (915) 20 (508) 18DE/11.1 3/93 ...