EA-IF-E2 EA ELEKTRO-AUTOMATIK, EA-IF-E2 Datasheet - Page 77

no-image

EA-IF-E2

Manufacturer Part Number
EA-IF-E2
Description
INTERFACE ETHERNET (EA-PSI/BCI800R)
Manufacturer
EA ELEKTRO-AUTOMATIK
Datasheet

Specifications of EA-IF-E2

Svhc
No SVHC (18-Jun-2010)
Accessory Type
Interface Card
Applications
Engineering Laboratory And Complex Industrial Application
Approval Bodies
CE / EN
Rohs Compliant
Yes
For Use With
EA Elektro-Automatik PSU
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
About the interface cards
© 009, Elektro-Automatik GmbH & Co. KG
5. Operation in other device series
5.1 Electronic loads EL 3000 / EL 9000
The electronic loads of the series EL3000 and EL9000 sup-
port the following interface cards:
IF-U1, IF-R1, IF-C1, IF-G1
Note about the GPIB card IF-G1: at devices with firmware
version
card) and must be configured to following settings:
- CAN Baudrate: 100kBd
- Bus termination: no
- Relocatable ID: 0
Also, in devices with firmware version
card is not correctly supported. We recommend an update.
Please contact your dealer.
At firmware version
The general functionality of the interface cards is the same
if used in a power supply. The amount of features is limited,
but also different.
Please refer to the previous sections for detailed information
about the interface cards.
You can configure the interface cards in the setup menu of
the devices. This is activated by turning the switch Level
Control to position Setup.
EL 3000/9000 Menu example of the CAN card:
EL 3000/9000 Menu example RS3 card:
Card found: IF-C1
CAN Baudrate: 10kBd
Card found: IF-C1
CAN Relocatable ID: 13
Card found: IF-C1
CAN Bus terminate: yes
Card found: IF-R1
RS232 Baudrate: 9600Bd
2.11
or older the card is detected as IF-C1 (CAN
3.01
or higher there are no limitations.
2.14
or lower, the
Depending on which card is equipped (the electronic loads
feature only one card slot) a different selection of parameters
is available. The parameters and their values are identical to
the ones explained in section 4.1 to 4.3, with the exception
that no
There are also no settable parameters for the USB and
IEEE cards.
5.2 Series PS 8000 T/ DT / 2U
Access to the device setup via pushbutton Fine (press >s
while output is „off“), for details of settings see user manual of
the device. The GPIB and USB cards are not configured.
5.3 Series PSI 800 R
The shortened type  cards are used here. Setup and c
configuration are explained in the user manual of the device
and also in section 4 (menu structure and handling of PSI
800 R series is similiar to PSI 9000 series).
Sample point
can be set at CAN.
EN
77

Related parts for EA-IF-E2