WT301 XP POWER, WT301 Datasheet

DC/DC CONVERTER, 5W 5V

WT301

Manufacturer Part Number
WT301
Description
DC/DC CONVERTER, 5W 5V
Manufacturer
XP POWER
Datasheet

Specifications of WT301

Output Type
Single
No. Of Output Channels
1
Input Voltage
18V To 36V
Power Rating
5W
Output Voltage
5V
Output Current
1A
Supply Voltage
24V
Dc / Dc Converter Case Style
DIP
Isolation Voltage
500VDC
Dc / Dc Converter O/p Type
Single
No. Of Outputs
1
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
5 Watts
WT Series
Specification
Input
Output
Input Voltage Range
Input Current (no load) • See table
Input Filter
Undervoltage Lockout
Output Voltage
Output Voltage Balance • ±1% max, dual output models
Initial Set Accuracy
Start Up Rise Time
Line Regulation
Load Regulation
Cross Regulation
Transient Response
Ripple & Noise
Short Circuit Protection • Continuous with auto recovery
Temperature
Coefficient
• 12 V (9-18 or 9-36 VDC - A version)
• Pi network
• Turn On > 65% nominal input
• see tables
• ±2% max
• 3 ms max
• ±0.5% max from high line to low line
• ±0.5% max for 10-100% load change for
• ±2.2% on dual output models
• <1.0% max deviation, recovering within
• 100 or 1.0% pk-pk, whichever is greater,
• ±0.05 /°C max
24 V (18-36 or 18-72 VDC - A version)
48 V (36-72 VDC)
Turn Off < 63% nominal input
single output models,
±1.0% max for 25-100% load change for
dual output models
200 µs for a 50% load change
20MHz BW
General
Environmental
EMC & Safety
Efficiency
Isolation
Switching Frequency
MTBF
Operating Temperature • -25 ºC to +70 ºC (see derating curve)
Case Temperature
Storage Temperature
Emissions
ESD Immunity
Radiated Immunity
Conducted Immunity
Safety
2:1 Input Range
Optional 4:1 Input Range
Isolated Outputs
Efficiency to 82%
Fully Regulated Outputs
Optional 3 kVDC Isolation
UL Approved Versions
• See table
• 500 VDC Input to Output (1000 M /80 pF)
• 100 kHz typical
• 1,000 kHrs to MIL-HDBK-217F
• +95 ºC max
• -40 ºC to +100 ºC
• EN55022, level A conducted
• EN61000-4-2, level 2
• EN61000-4-3 3 V/m
• EN61000-4-6 3 V rms
• UL1950 (for XU versions only)
Optional high isolation version,
3000 VDC Input to Output, add suffix ‘X’
Perf Criteria A
Perf Criteria A
Perf Criteria A
EN55022, level A radiated
xppower.com

Related parts for WT301

WT301 Summary of contents

Page 1

Watts WT Series Specification Input Input Voltage Range • (9-18 or 9-36 VDC - A version (18-36 or 18-72 VDC - A version (36-72 VDC) Input Current (no load) • See table Input ...

Page 2

... Ambient Temperature (ºC) WT Series (6) Efficiency Number 70% WT200 76% WT201 80% WT202 80% WT203 76% WT204 80% WT205 80% WT206 70% WT300 78% WT301 82% WT302 82% WT303 78% WT304 81% WT305 81% WT306 98 mA 70% WT400 78% WT401 81% WT402 81% WT403 78% WT404 81% WT405 81% WT406 OPTION ‘X’ / ‘XU’ PIN CONNECTIONS Pin Single Output Dual Output ...

Related keywords