FD3125 EATON CUTLER HAMMER, FD3125 Datasheet - Page 197

CIRCUIT BREAKER, THERMAL MAG, 3P, 125A

FD3125

Manufacturer Part Number
FD3125
Description
CIRCUIT BREAKER, THERMAL MAG, 3P, 125A
Manufacturer
EATON CUTLER HAMMER
Series
Cr
Datasheet

Specifications of FD3125

Actuator Style
Toggle
No. Of Poles
3
Current Rating
125A
Voltage Rating Vdc
250V
Voltage Rating Vac
600V
Mounting Type
DIN Rail
Terminals
Screw
November 2008
Enclosures
Type 1 General Purpose
Type 1 enclosed breakers are designed
for use in commercial buildings, apart-
ment buildings and other areas where
a general purpose enclosure is appli-
cable. The breaker is front operable
and is capable of being padlocked in
either the ON or OFF position. Ratings
through 1200 amperes are listed
with Underwriters Laboratories as
approved for service entrance applica-
tion. Both surface and flush mounted
enclosures are available.
Figure 12-41. Type 1 Surface Mounted
Table 12-320. Enclosure Selection Data
CA08101001E
Breaker
Frame
Amperes
FG
15 – 225
JG
175 – 250
KG
300 – 400
LG
450 – 600
NG
700 – 1200
Surface or flush mounting.
15 – 1200 ampere range.
600 Vac, 500 Vdc.
D
E
Enclosure
Type
Class
Type 1
Type 3R
Type 12
Type 1
Type 3R
Type 12
Type 1
Type 3R
Type 12
Type 1
Type 3R
Type 12
Type 1
Type 3R
Type 12
B
Dimensions
A
Inches mm Inches mm Inches mm Inches mm Inches mm
23.25
25.66
25.66
34.70
37.50
37.53
38.81
41.69
41.69
45.88
48.31
48.31
61.22
63.59
63.59
A
1165
1227
1227
1555
1615
1615
591
652
652
881
891
953
986
997
997
C
B
10.92
11.56
11.56
11.06
11.75
11.75
14.31
14.91
14.91
21.44
22.00
22.00
8.41
8.84
8.84
214
225
226
227
294
294
281
298
298
364
379
379
545
559
559
C
10.22
10.22
10.94
14.06
14.06
12.38
15.50
15.50
15.41
17.63
17.63
Type 3R Rainproof Surface
Mounting
This general purpose outdoor service
center employs a circuit breaker inside
a weatherproof sheet steel breaker
enclosure to serve as a main discon-
nect and protective device for feeder
circuits. Ratings through 1200 amperes
are listed by Underwriters Laboratories
as suitable for service entrance
application.
Figure 12-42. Type 3R Rainproof
6.28
9.31
9.31
7.20
For more information visit: www.eaton.com
Interchangeable hubs
(through 400 amperes).
15 – 1200 ampere range.
600 Vac, 500 Vdc.
Series C Molded Case Circuit Breakers
Engine Generator Circuit Breakers
Enclosures
160
237
238
183
260
260
278
357
357
314
394
394
391
448
448
A
D
D
18.75
24.28
24.28
30.00
35.77
35.77
34.00
39.90
39.90
46.56
46.56
46.56
61.84
61.84
61.84
E
B
OFF
1014
1015
1183
1183
1183
1571
1571
1571
ON
476
617
618
762
909
909
869
E
1.20
1.70
1.70
1.88
1.94
1.94
2.28
1.97
1.97
1.91
1.92
1.92
1.97
1.97
1.97
C
31
43
43
48
49
49
58
50
50
48
49
49
50
50
50
Approx.
Weight
Lbs.
(kg)
178 (81)
175 (79)
170 (77)
15 (7)
19 (9)
18 (8)
31 (14)
40 (18)
37 (17)
53 (24)
60 (27)
53 (24)
81 (37)
84 (38)
81 (37)
Conduit Sizes,
Inches
.25, .50, .75, 1, 1.25, 1.50, 2, 2.50
.25, .50, .75, 1, 1.25, 1.50, 2, 2.50
.25, .50, 2, 2.50, 3
.25, .50, 2, 2.50, 3
.25, .50, .75, 1.50, 2, 2.50, 3, 3.50
.25, .50, .75, 2.50, 3, 3.50
.25, .50, .75, 3, 3.50, 4
.25, .50, .75, 3, 3.50, 4
Type 12 Dustproof Surface
Mounting
The Type 12 enclosure is designed
in line with specifications for special
industry applications where unusually
severe conditions involving oil, coolant,
dust and other foreign materials exist
in the operating atmosphere. The handle
padlocks in the OFF position and the
cover is interlocked with the handle
mechanism to prevent opening the
cover with the circuit breaker in the
ON position. Ratings through 1200
amperes are listed by Underwriters
Laboratories as suitable for service
entrance application.
Figure 12-43. Type 12, 12K Dustproof
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . CB-2
No knockouts or other openings.
15 – 1200 ampere range.
600 Vac, 500 Vdc.
A
D
E
B
OF
Catalog
Number
SFDN225
RFDN225
JFDN225
SJDN250
RJDN250
JJDN250
SKDN400
RKDN400
JKDN400
SLDN600
RLDN600
JLDN600
SNDN1200
RNDN1200
JNDN1200
C
Price
U.S. $
12-197
12

Related parts for FD3125