E3S-CL2 Omron, E3S-CL2 Datasheet - Page 8

50CM, ADJ SENSING DIST, NPN/PNP

E3S-CL2

Manufacturer Part Number
E3S-CL2
Description
50CM, ADJ SENSING DIST, NPN/PNP
Manufacturer
Omron
Series
E3S-CLr
Datasheets

Specifications of E3S-CL2

Rohs Compliant
YES
Sensing Distance
0.197" ~ 7.874" (5mm ~ 200mm) ADJ
Sensing Method
Reflective, Diffuse
Sensing Object
Black Paper, White Paper
Output Configuration
NPN/PNP - Dark-ON/Light-ON - Selectable
Sensing Light
Infrared
Mounting Type
Bracket Mount
Current - Supply
35mA
Voltage - Supply
10 V ~ 30 V
Package / Case
Module, Pre-Wired
Features
NPN/PNP Selectable Output
Sensing Range
50mm To 500mm
Sensor Output
Open Collector
Supply Voltage Range Dc
10V To 30V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E3S-CL2
Manufacturer:
OMRON
Quantity:
475
Dimensions
E3S-CL1
E3S-CL2
Note: The output selector, operation selector, and distance setting adjuster are located inside the cover.
54.5
16
28
Two, M4 hex bolts
with slit lock washers
21
2
16.1
Receiver
With Mounting Bracket Attached
Detecting axis
15.4
Emitter, optical axis
16.5
9.1
42.6
1.1
Stability indicator
19.7
Light indicator
12
Tolerance class IT16 applies to dimensions in this datasheet unless otherwise specified.
9.2
7.3
37.2
40
44.7
6.2
4.2
23.8
40
Two, M4
11.7
Stainless steel
4.2
E3S-CL1:
4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.2 mm
Insulator diameter: 1.1 mm),
Standard length: 2 m
E3S-CL2:
4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section area: 0.2 mm
Insulator diameter: 1.2 mm),
Standard length: 2 m
20
Mounting Holes
25.4
Two, M4
E3S-CL
2
(AWG24),
(Unit: mm)
2
(AWG24),
8