SLW360 TIMEGUARD, SLW360 Datasheet

PIR, 360 DEG, SURFACE MOUNT, CEILING

SLW360

Manufacturer Part Number
SLW360
Description
PIR, 360 DEG, SURFACE MOUNT, CEILING
Manufacturer
TIMEGUARD
Datasheet

Specifications of SLW360

Beam Angle
360°
Length
53mm
Depth
103mm
Colour
White
External Width
103mm
Contact Voltage Ac Max
230V
Frequency
50Hz
Mounting Type
Surface Mount
Range
6m
Svhc
No SVHC (15-Dec-2010)
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
360º SURFACE MOUNT
CEILING PIR LIGHT
CONTROLLER
Cat No. SLW360

Related parts for SLW360

SLW360 Summary of contents

Page 1

... SURFACE MOUNT CEILING PIR LIGHT CONTROLLER Cat No. SLW360 ...

Page 2

... Introduction The SLW360 utilises passive infrared technology to detect heat radiation of moving human bodies.Upon detection, the attached lighting load will illuminate for a user-determined time period. An integral daylight sensor ensures day or night-only operation. Important Information: Light Pollution and considerate Lighting Please be aware of the annoyance over-lighting an area can cause to your immediate neighbours ...

Page 3

Time On setting H Factory fitted bridge wire REMOVED In the above illustration: - the L1 L2 terminals are used to control a DC load or if the load uses a different phase or voltage supply from ...

Page 4

Parts included • PIR Sensor unit. • Instruction manual. Please keep safe for future reference. • Accessory Pack. Includes 2 x wall plugs wall fixing screws lens mask sticker. • outdoor mounting sealing gasket. ...

Page 5

The sensor is more sensitive to movement ACROSS its field of vision than to movement directly TOWARDS (see diagram B). Therefore position the unit so that the sensor looks ACROSS the likely approach path. Avoid positioning the sensor where there ...

Page 6

PIERCE & PASS THE INCOMING AND OUTGOING CABLE THROUGH THE GROMMET BEFORE SECURING CEILING MOUNTING PLATE TO CEILING recommended that the grommet is pierced with a screwdriver to ensure a better seal. Connection THERE ARE 2 POSSIBLE CONNECTION ...

Page 7

See diagram “I” for ceiling mounting assembly method. Fit the sensor assembly to the ceiling, if mounting outdoors essential that the sponge gasket is placed between the ceiling mounting plate and the sensor itself to ensure a good ...

Page 8

Start moving again. As you cross each "zone" the lamp will illuminate. Repeat the above, walking at various distances and angles to the unit. This will help you to establish the detection pattern. Masking the Sensor Lens To reduce the ...

Page 9

At this position, the unit should become operative at approximately the same level of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when it is quite light), adjust the ...

Page 10

Troubleshooting guide Problem • Lamp stays ON all the time at night. • PIR keeps activating for no reason (at random). • PIR sensor will not operate at all. 9 • The PIR sensor will not operate at night. • ...

Page 11

Problem • Detection range varies from day to day Technical specifications Detection Range: Detection Angle: 10 Power Supply: Maximum Switchable Load: Time On Adjustment: Dusk Level Adjustment: Environmental Protection: Conforms to Directives: Solution PIR detectors are influenced by climatic conditions. ...

Page 12

... For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515. 020-8450-0515 For a product brochure please contact: Victory Park, 400 Edgware Road, or email csc@timeguard.com 3 Year Guarantee THREE YEAR 3 GUARANTEE HELPLINE Timeguard Ltd ...