117643-52 AMETEK, 117643-52 Datasheet

BLOWER, 145MM, 240V, 400W

117643-52

Manufacturer Part Number
117643-52
Description
BLOWER, 145MM, 240V, 400W
Manufacturer
AMETEK
Series
Windjammerr
Type
Canisterr
Datasheets

Specifications of 117643-52

External Height
157.48mm
Current Type
AC
Supply Voltage
240VAC
Current Rating
5A
Flow Rate
54l/s
Power Connection Type
Pins
Depth
132.59mm
External Length / Height
157.48mm
Flow
RoHS Compliant
Air Flow
125 CFM
Brand/series
IntelliGen™
Configuration
Bypass
Controls
Electrical
Current, Rating
5 A
Diameter, Inlet
1.75 "
Diameter, Outlet
1.75 "
Dimensions
145Dia x 132.59L mm
Power, Rating
400 W
Special Features
Speed Control
Static Pressure
45 in.-H2O
Temperature, Operating, Maximum
+50 °C
Temperature, Operating, Minimum
0 °C
Termination
Terminals
Voltage, Rating
240 VAC
Weight
6 lbs.
Outer Diameter
145mm
Flow Rate - Imperial
114cu.ft/min
Flow Rate - Metric
522m3/h
Rohs Compliant
Yes
External Depth
132.59mm
Lead Free Status / Rohs Status
RoHS Compliant part
5.7” (145mm) BLDC Bypass Blower
*These part numbers are available through AMETEK Rotron distributors.
NOTES:
• Nominal input voltage: 240 Volts AC RMS +/- 10%, 50/60Hz
• Input current: 5 amps AC RMS maximum
• Temperature: Working Air: 0°C to 50°C, Ambient Air: 0°C to 50°C, Storage Air: -40°C to 85°C
• Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
• Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC
Blower Data
Stages
Vacuum, Max. (Sealed Vacuum)
Pressure, Max. (Sealed Pressure)
Flow Rate, Max. (Open Flow)
Inlet/Outlet Diameter
(Dimension “D” above)
Length (Dimension “I” above)
Length (Dimension “L” above)
Air Flow
0 CFM
10 CFM
20 CFM
30 CFM
40 CFM
50 CFM
60 CFM
70 CFM
80 CFM
90 CFM
100 CFM
110 CFM
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
Measure
Unit of
in. H
in. H
in. H
in. H
in. H
in. H
in. H
in. H
in. H
in. H
in. H
in. H
n. H
in. H
inches
inches
inches
mBar
mBar
L/sec
CFM
mm
mm
mm
2
2
2
2
2
2
2
2
2
2
2
2
2
2
O
O
O
O
O
O
O
O
O
O
O
O
O
O
117634 M*
117640 E*
129.03
64.26
31.75
30.3
27.9
26.2
23.6
19.0
13.3
1.25
2.53
5.08
7.0
3.7
28
69
30
74
69
33
1
Typical Performance Points
Standard Flow
117633 M
117639 E
152.15
31.75
31.75
51.0
44.2
41.8
35.9
27.8
16.6
112
126
1.25
1.25
5.99
36
3.7
45
51
62
29
2
Pressure
117632 M*
117638 E*
175.01
54.36
Part Number
31.75
69.9
59.9
52.8
44.1
32.1
18.1
1.25
2.14
6.89
149
174
60
70
58
27
3
400 WATT, 240 VOLT
117637 M*
117643 E*
132.59
11.94
44.45
24.8
23.6
22.6
21.5
19.5
17.9
16.1
13.8
12.0
1.75
5.22
114
8.7
6.7
.47
23
57
25
62
54
1
0
High Flow
117636 M*
117642 E*
159.26
38.86
44.45
44.6
41.0
39.8
35.8
32.0
28.0
23.9
17.9
12.1
1.75
1.53
6.27
112
39
97
45
97
46
2
0
117635 M*
117641 E*
184.91
44.45
64.26
1.75
2.53
7.28
61.5
55.8
51.5
46.0
40.1
34.2
28.2
19.6
131
151
8.1
53
61
86
41
3

Related parts for 117643-52

117643-52 Summary of contents

Page 1

... WATT, 240 VOLT High Flow 117637 M* 117636 M* 117635 M* 117643 E* 117642 E* 117641 131 112 151 114 1.75 1.75 1.75 44.45 44 ...

Page 2

... Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications ...

Related keywords