ET2H30S SOLA HEVI DUTY, ET2H30S Datasheet
ET2H30S
Specifications of ET2H30S
Related parts for ET2H30S
ET2H30S Summary of contents
Page 1
... General Purpose Energy effi cient dry-type transformers 600 Volt Class, isolation type, single and three phase, 15 kVA through 500 kVA. Indoor and outdoor models available. Accessories and Optional Design Styles • Electrostatic shield for quality power • Wall mount ing brackets (500 lbs maximum) (Item WB1C) • ...
Page 2
... Style and Electrical Connections can be found on pages 199-200. Selection Tables: Three Phase Group A: 480 Volt Primary, 208/120 Secondary Catalog NEMA 3R kVA Number Weather Shield* ET2H15*** 15 WS-02 ET2H15S ET2H30*** 30 WS-14 ET2H30S ET2H45*** 45 WS-14 ET2H45S ET2H75*** 75 WS-30 ET2H75S 112.5 ET2H112S WS-30 150 ET2H150S WS-10 ...
Page 3
... Electrical Connections and Design Style can be found on pages 197 and 204 respectively. *** See the Technical Notes section with respect to capacity of center tap. **** Unshielded model. contact Technical Services at (800) 377-4384 with any ques tions. Ventilated Distribution Transformers Height Width Depth Approx. Ship ...
Page 4
... Ventilated Distribution Transformers Selection Tables: Three Phase Group E: 208 Volt Primary, 208Y/120 Secondary Catalog NEMA 3R kVA Number Weather Shield* 15 ET3H15S WS-02 30 ET3H30S WS-14 45 ET3H45S WS-14 75 ET3H75S WS-30 112.5 ET3H112S WS-30 150 ET3H150S WS-10 Group F: 240 Volt Primary, 208Y/120 Secondary ...
Page 5
... ET79H75S WS-30 112.5 ET79H112S WS-30 150 ET79H150S WS-10 Group K: 480 Volt Primary, 208Y/120 Secondary, 60 Hz, Copper-Wound Catalog NEMA 3R kVA Number Weather Shield* 15 ET2H15SCU WS-02 30 ET2H30SCU WS-14 45 ET2H45SCU WS-14 75 ET2H75SCU WS-30 112.5 ET2H112SCU WS-30 150 ET2H150SCU WS-10 225 ET2H225SCU WS-11 300 ...
Page 6
... Figure 2). Low temperature rise transformers are designed for any criti- cal application requiring extra overload capability, lower than average total losses and/or cooler operating temperatures. All are available with either a 115° ...
Page 7
... Weather shields (set of two) must be ordered separately. **Design Style and Electrical Connections can be found on pages 204-205. ***See the Technical Notes section with respect to capacity of center tap. contact Technical Services at (800) 377-4384 with any ques tions. Ventilated Distribution Transformers o C Rise o C Rise ...
Page 8
... Ventilated Distribution Transformers Selection Tables: Low Temperature Rise, Single Phase, 115 Group 1: 240 x 480 Volt Primary, 120/240 Secondary, 60 Hz, 115 Catalog Number NEMA 3R kVA 115°C Rise Weather Shield* 15 ES5HF15S WS-15 25 ES5HF25S WS-15 37.5 ES5HF37S WS-17 50 ES5HF50S WS-17 75 ES5HF75S WS-09 100 ...
Page 9
... Weather shields (set of two) must be ordered separately. **Design Style and Electrical Connections can be found on pages 204-205. ***See the Technical Notes section with respect to capacity of center tap. contact Technical Services at (800) 377-4384 with any ques tions. Ventilated Distribution Transformers o C Rise o C Rise ...
Page 10
... Chart A. The K-Factor rating is an index of the trans form er’s ability to withstand harmonic con tent while operating within the temperature limits of its insulating system. SolaHD K-Factor transformers have UL ratings of K-4, K-13, and K-20. The SolaHD K-Factor design is a specialized transformer that off ers these benefi ts: • ...
Page 11
... WS-11 300 3H20T2H300S WS-12 Notes: * Weather shields (set of two) must be ordered separately. **Design Style and Electrical Connections can be found on pages 204-205. contact Technical Services at (800) 377-4384 with any ques tions. Ventilated Distribution Transformers Height Width Depth Approx. Ship (inch) (inch) (inch) ...
Page 12
... Ventilated Distribution Transformers Electrical Connections (Single Phase) 240 x 480 Volt Primary, 120/240 Volt Sec ond ary 1 Taps: 2, 2½% FCAN; 4, 2½% FCBN SHIELD Connect Primary Voltage Interconnect Lines To 504 & H2 492 & H2 480 & H2 468 & H2 456 & H2 444 & H2 ...
Page 13
... ET81 Series contact Technical Services at (800) 377-4384 with any ques tions. Ventilated Distribution Transformers 480 Volt Primary, 240 W/120 CT Volt Sec ond ary Taps: 2, 2½% FCAN; 4, 2½% FCBN SHIELD X6 X1 ...
Page 14
... Ventilated Distribution Transformers Electrical Connections (Three Phase) Δ 240 Volt Primary 11 208Y/120 Volt Secondary Taps: 2, 2½% FCAN; 4, 2½% FCBN SHIELD Primary H1-H2-H3 Secondary Voltage @ Tap Voltage X1, X2, X3 X0- X1, X2 252 2 246 3 240 4 234 208 120 5 228 6 222 7 216 ET6 Series Δ ...