97F9851 GENTEQ, 97F9851 Datasheet

CAPACITOR MOTOR RUN 45/5UF, 440VAC, CASE T

97F9851

Manufacturer Part Number
97F9851
Description
CAPACITOR MOTOR RUN 45/5UF, 440VAC, CASE T
Manufacturer
GENTEQ
Series
Life-Liner
Datasheet

Specifications of 97F9851

Capacitance 1
45µF
Capacitance 2
5µF
Voltage Rating
440VAC
Capacitor Dielectric Type
Polypropylene
Capacitance Tolerance
± 6%
Capacitor Mounting
Quick Connect
Lead Spacing
20.57mm
Capacitance
45 μF,5 μF
Material, Element
Polypropylene Metallized
Special Features
Motor Run
Termination
Quick Connect
Tolerance
±6 %
Voltage, Rating
440 VAC
Capacitance, Dual
45 / 5 UF
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Life-Line
The Life-Line Capacitor Kit is the all in one replacement kit for your single
and dual run capacitor needs. In addition to many single capacitor ratings,
this kit has been designed to cover 48 of the most common dual ratings in
both in 370VAC and 440VAC applications.
Included in this kit is the following:
Life-Line Kit Featuring Genteq Capacitors
Note: Also available with PRoLINE capacitors (see table 4 on page 16)
u
For direct replacements, please refer to tables 3 and 4 on page 16. You can
obtain direct replacements from your local distributor.
Everything needed to select, wire, and mount the replacement capacitor(s) is
included in this kit.
This kit saves time and money by having exactly what you need on the job
and the ability to only use and replace only what you need.
The UL approved Life-Line Device (patent pending) gives you the ability to
turn six capacitors into 48 duals with no guess work. With a simple wiring
diagram you will have the system up and running in no time with the safe
and reliable installation of multiple capacitors using the technology of
parallel capacitors.
Genteq
For contents of bracket kits, see figure G on page 6.
10uF / 440VAC
Life-Line
Life-Line
• 6 Best in Class Motor Run Capacitors
• 2 Life-Line “Spider” Devices
• 1 Capacitor Mounting Hardware Kit
• 1 Device Mounting Hardware Kit
• 1 Robust Carrying Case
Genteq
CID-001
CID-001
15uF / 440VAC
Complete Kit
27L1027S
LCKG-001
Device
Device
97F9625S
Capacitor Kit
- 2 -
(fig. B)
55/7.5uF / 440VAC
www.RegalBeloitCapacitors.com
Genteq
Genteq
Genteq
5uF / 440VAC
45/5uF / 440VAC
Device Brackets
LCK-DBA-001
Genteq
97F9874S
Life-Line
25/5uF / 440VAC
27L1024S
Capacitor Brackets
Device
97F9851S
CAP3001 Rev 5/09
LCK-SBA-001
LCK-CID-001
97F9978S
“Spider”
u
(fig. A)
u

Related parts for 97F9851

97F9851 Summary of contents

Page 1

... Life-Line (fig. B) Genteq 97F9874S 55/7.5uF / 440VAC Genteq 45/5uF / 440VAC Device Brackets LCK-DBA-001 Genteq 25/5uF / 440VAC Genteq 5uF / 440VAC - 2 - www.RegalBeloitCapacitors.com “Spider” Device (fig. A) LCK-CID-001 97F9851S u Capacitor Brackets LCK-SBA-001 u 97F9978S 27L1024S CAP3001 Rev 5/09 ...

Page 2

... If one replacement capacitor will not directly replace the failed capacitor, the add on capacitor section will show you how to select the correct combination of capacitors. The ratings listed on this chart are in microfarads (mf). Always replace a failed capacitor with the exact microfarad rating. All of these capacitors are rated at 440VAC ...

Page 3

... C) Dual Capacitor FAN HERM C FAN WIRING THe LIFe-LINe DevICe To THe CAPACIToRS Step 1: Connect hermatic (H), fan (F) and common (C) wires from the device to their respective terminals on the dual run capacitor Step 2: Connect the (C) and (+) wires to either of the terminals on the additional capacitor C) ...

Page 4

... Life-Line Device. Step 5: Connect the (C) wire from the Life-Line Device to the appropriate line voltage according the HVAC systems schematics. NOTE start device is used on the compressor, then connect per manufacturer specifications to the dual run capacitor. CAP3001 Rev 5/09 www.RegalBeloitCapacitors.com D). (as seen in fig. E ...

Page 5

... C on page 4, it will be time to mount the capacitors into the system. If one capacitor will directly replace the failed capacitor, then mount using the supplied brackets or existing mounting hardware ...

Page 6

... LIFe-LINe SoLuTIoNS When mounting a combination of capacitors, select the brackets that fit the selected capacitors and determine from the space available in the HVAC system how to configure the mounts including the Life-Line Device. The add–on capacitor can be rotated around the circumference of the dual ...

Page 7

... LIFe-LINe SoLuTIoNS oPTIoN 1A – INDIvIDuALLy mouNTING ComPoNeNTS BeFoRe (fig. M) Failed Capacitor AFTeR Dual Rated Capacitor (CoNTINueD www.RegalBeloitCapacitors.com Life-Line ‘Spider’ Device Additional Capacitor CAP3001 Rev 5/09 ...

Page 8

... LIFe-LINe SoLuTIoNS oPTIoN 1B – INDIvIDuALLy mouNTING ComPoNeNTS BeFoRe (fig. N) Failed Capacitor AFTeR Additional Capacitor Dual Rated Capacitor CAP3001 Rev 5/09 www.RegalBeloitCapacitors.com (CoNTINueD Life-Line ‘Spider’ Device ...

Page 9

... LIFe-LINe SoLuTIoNS oPTIoN 2 – SINGLe STACKeD mouNTING BeFoRe (fig. O) AFTeR Dual Rated Capacitor (CoNTINueD) Failed Capacitor Life-Line ‘Spider’ Device Additional Capacitor - 10 - www.RegalBeloitCapacitors.com CAP3001 Rev 5/09 ...

Page 10

... LIFe-LINe SoLuTIoNS oPTIoN 3 – DouBLe STACKeD mouNTING BeFoRe (fig. P) Failed Capacitor AFTeR Dual Rated Capacitor Additional Capacitor CAP3001 Rev 5/09 www.RegalBeloitCapacitors.com (CoNTINueD Life-Line ‘Spider’ Device ...

Page 11

... NoT determine actual capacitance or capability. Using an ohm meter set to the highest scale, connect the leads of the ohm meter across the terminals of the capacitor. on dual run capacitors, check (C) to (FAN) or (C) to (HERM) as two separate checks. Leave the leads connected to the capacitor for a couple of seconds. Then simply reverse the meter leads on the two thermals being checked ...

Page 12

... Using a capacitance meter, set to the appropriate scale. If applicable, connect the leads of the meter across the terminals of the capacitor. on dual run capacitors, check (C) to (FAN) or (C) to (HERM) as two separate checks. Wait a few seconds for the reading on the meter. Most capacitor manufacturers and HVAC OEMs specify ± 6% tolerance on microfarads (mf) of the capacitor ...

Page 13

... Why Do Capacitors Fail? Q: Why are there so many infant capacitor failures Substandard materials 2. Poor capacitor design 3. Improper & inadequate process control Q: What causes capacitor degradation Excessive temperatures to the capacitor designs 2. Voltages excessive to the design of the capacitor Q: What are the signs of a failing capacitor ...

Page 14

... One way to get a quick estimate of your meters accuracy is to measure the capacitance of a new capacitor. If the metered rating is significantly above the rating on the capacitor you may want to take that into consideration on future readings. CAP3001 Rev 5/09 www.RegalBeloitCapacitors.com (table 2) Meter A Meter B Meter B Delta (mf) ...

Page 15

... Life-Line Capacitor Kit Featuring Genteq Capacitors Part Number LCKG-001 Part Number mf Rating 27L1024S 5 mf 27L1027S 10 mf 97F9625S 15 mf 97F9978S 25/5 mf 97F9851S 45/5 mf 97F9874S 55/7.5 mf Part Number LCK-SBA-001 LCK-DBA-001 CID-001 Life-Line Capacitor Kit Featuring PROLINE Capacitors Part Number LCKP-001 Part Number mf Rating ...

Related keywords