NHD-240128WG-BYFH-VZ#020 Newhaven Display, NHD-240128WG-BYFH-VZ#020 Datasheet - Page 9

LCD Graphic Display Modules & Accessories STN-Y/G Transfl 144.0 x 104.0

NHD-240128WG-BYFH-VZ#020

Manufacturer Part Number
NHD-240128WG-BYFH-VZ#020
Description
LCD Graphic Display Modules & Accessories STN-Y/G Transfl 144.0 x 104.0
Manufacturer
Newhaven Display
Datasheet

Specifications of NHD-240128WG-BYFH-VZ#020

Pixel Density
240 x 128
Fluid Type
FSTN Positive
Module Size (w X H X T)
144 mm x 104 mm x 14.3 mm
Viewing Area (w X H)
108 mm x 57.6 mm
Backlighting
LED White
Background Color
White
Operating Temperature Range
- 20 C to + 70 C
Attached Touch Screen
No
Display Mode
Transflective
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
 
Quality Information 
High Temperature storage 
Low Temperature storage 
High Temperature 
Operation 
Low Temperature 
Operation 
High Temperature / 
Humidity Operation 
Thermal Shock resistance 
Vibration test 
Static electricity test 
Note 1: No condensation to be observed. 
Note 2: Conducted after 4 hours of storage at 25
Note 3:
 
 
Precautions for using LCDs/LCMs 
See Precautions at www.newhavendisplay.com/specs/precautions.pdf 
 
Warranty Information and Terms & Conditions 
http://www.newhavendisplay.com/index.php?main_page=terms 
 
 
 
Test Item 
 Test performed on product itself, not inside a container. 
storage temperature for a long time. 
Endurance test applying the low storage 
temperature for a long time. 
Endurance test applying the electric stress 
(voltage & current) and the high thermal 
stress for a long time. 
Endurance test applying the electric stress 
(voltage & current) and the low thermal 
stress for a long time. 
Endurance test applying the electric stress 
(voltage & current) and the high thermal 
with high humidity stress for a long time. 
Endurance test applying the electric stress 
(voltage & current) during a cycle of low 
and high thermal stress.  
Endurance test applying vibration to 
simulate transportation and use. 
Endurance test applying electric static 
discharge. 
Endurance test applying the high 
Content of Test 
⁰C, 0%RH. 
[9] 
+80⁰C , 48hrs
‐30⁰C , 48hrs
+70⁰C , 48hrs
‐20⁰C , 48hrs
+40⁰C , 90% RH ,  48hrs 
0⁰C,30min ‐> 25⁰C,5min ‐> 
50⁰C,30min = 1 cycle 
10 cycles 
10‐55Hz , 15mm amplitude. 
60 sec in each of 3 directions 
X,Y,Z 
For 15 minutes 
VS=800V, RS=1.5kΩ, CS=100pF 
 One time 
Test Condition 
Note
1,2
1,2
1,2
 
 

Related parts for NHD-240128WG-BYFH-VZ#020