6-1394461-6 TE Connectivity, 6-1394461-6 Datasheet

PLUG, SOLARLOK, 6MM, NEG

6-1394461-6

Manufacturer Part Number
6-1394461-6
Description
PLUG, SOLARLOK, 6MM, NEG
Manufacturer
TE Connectivity
Series
SolarLokr
Datasheets

Specifications of 6-1394461-6

Gender
M
Body Orientation
Straight
Housing Material
Polyphenylene Oxide
Number Of Contacts
1POS
Number Of Ports
1Port
Number Of Terminals
1
Current Rating (max)
25A
Pitch (mm)
Not Requiredmm
Contact Material
Copper Zinc
Operating Temp Range
-40C to 105C
Mounting Style
Cable
Contact Plating
Silver
Product Depth (mm)
18mm
Contact Termination
Crimp
No. Of Contacts
1
Connector Mounting
Cable
Colour
Black
Connector Mounting Orientation
Cable
Rohs Compliant
Yes
Product Type
Connector
Insulation Diameter (mm [in])
5.50 - 8.00 [.216 - .315]
Type Of Connector
Cable Coupler
Wire Size (mm² [awg])
6.0² [10]
Keying
Minus
Contact Base Material
Copper Zinc
Contact Finish
Silver Plate
Housing Color
Black
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Packaging Quantity
100
Lead Free Status / RoHS Status
Compliant
SOLARLOK
Photovoltaic Interconnection System
RoHS
Ready

Related parts for 6-1394461-6

6-1394461-6 Summary of contents

Page 1

SOLARLOK Photovoltaic Interconnection System RoHS Ready ...

Page 2

... Large Junction Box – Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 5-Rail Junction Box – Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Medium Junction Box – Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Small Junction Box – Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Eco Junction Box – Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Slim Junction Box – Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Micro Junction Box – Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Junction Boxes for Building integrated PV Applications (BiPV) Solar Labels ...

Page 3

... SOLARLOK connector established IP 67 sealing require- system. ment in the photovoltaic industry. Mating safety is provided by SOLARLOK delivers a flexible polarity keyed housings, fully ...

Page 4

... Consult Tyco Electronics for latest specifications. Rated Current Diodes (IEC 61215, Edition 2) (Ampere) 5 6.0 5 8.5 5 13.0 3 6.0 3 8.5 3 13.0 Rated Current Diodes (IEC 61215, Edition 2) (Ampere) 5 6.0 5 8.5 5 13.0 3 6.0 3 8.5 3 13.0 Rated Current Cable Length Diodes (IEC 61215, Edition 2) (mm) ...

Page 5

... All dimensions are in millimeters unless otherwise specified. All specifications subject to change. Consult Tyco Electronics for latest specifications. Rated Current Diodes (IEC 61215, Edition 2) (Ampere) 4 8.5 4 13.0 Rated Current Diodes (IEC 61215, Edition 2) (Ampere) 4 8.5 4 13.0 Catalog 889753-3 Revised 9-2009 + W: 140 mm H: 22.5 mm Cable Length ...

Page 6

... All dimensions are in millimeters unless otherwise specified. All specifications subject to change. Consult Tyco Electronics for latest specifications. W: 115 mm Rated Current Diodes (IEC 61215, Edition 2) (Ampere) 3 6.0 3 8.5 3 13.0 Rated Current Diodes (IEC 61215, Edition 2) (Ampere) 3 6.0 3 8.5 3 13.0 Catalog 889753-3 Revised 9-2009 + H: 22.5 mm Cable Length Wire Size 2 ...

Page 7

... Optional with double-sided adhesive tape (specifications of the adhesive tape can be found in the datasheets of the manufacturer). All dimensions are in millimeters unless otherwise specified. All specifications subject to change. Consult Tyco Electronics for latest specifications. Rated Current Cable Length Diodes (IEC 61215, Edition 2) (mm) (Ampere) 3 8.5 1,000 3 8 ...

Page 8

... All dimensions are in millimeters unless otherwise specified. All specifications subject to change. Consult Tyco Electronics for latest specifications Rated Current Diodes (IEC 61215, Edition 2) (Ampere) 2 6.5 2 10.5 2 14.0 Rated Current Diodes (IEC 61215, Edition 2) (Ampere) 2 6.5 2 10.5 2 14.0 Catalog 889753-3 Revised 9-2009 + Cable Length Wire Size 2 ...

Page 9

... Optional with double-sided adhesive tape (specifications of the adhesive tape can be found in the datasheets of the manufacturer). All dimensions are in millimeters unless otherwise specified. All specifications subject to change. Consult Tyco Electronics for latest specifications. Rated Current Cable Length (IEC 61215, Edition 2) Diodes (Ampere ...

Page 10

... Optional with double-sided adhesive tape (specifications of the adhesive tape can be found in the datasheets of the manufacturer). 8 All dimensions are in millimeters unless otherwise specified. All specifications subject to change. Consult Tyco Electronics for latest specifications Rated Current (IEC 61215, Edition 2) Diodes (Ampere Rated Current Diodes ...

Page 11

... Optional with double-sided adhesive tape (specifications of the adhesive tape can be found in the datasheets of the manufacturer). All dimensions are in millimeters unless otherwise specified. All specifications subject to change. Consult Tyco Electronics for latest specifications. Rated Current Diodes (IEC 61215, Edition 2) (Ampere Catalog 889753-3 Revised 9-2009 38 ...

Page 12

... All dimensions are in millimeters unless otherwise specified. All specifications subject to change. Consult Tyco Electronics for latest specifications. 105.8 15.5 12.5 10.0 Diodes 1987293-3 1 Catalog 889753-3 12.5 Rated Current (IEC 61215, Edition 2) Connection Type (Ampere) with Slim Line Connector System 10 (see Page 15) Revised 9-2009 ...

Page 13

... Female Cable Coupler, Plus Contact 1971131-2 Female Cable Coupler, Minus Contact 1971133-1 Termination Connector Catalog 889753-3 (continued) 131.0 Rated Current (IEC 61215, Edition 2) Connection Type (Ampere) Specific Connector System 11 (see table below) These specific Slim Connec- tors can be equipped with contacts of the SOLARLOK system on page 28 ...

Page 14

... SOLARLOK Photovoltaic Interconnection System Solar Labels Product Features I UV resistant I Meet IEC61215 Edition 2.0, IEC61646 Edition 2.0 I UL- certified I Withstand harsh outdoor environments I Labels can be customized to customer requirements (design, logos, colors, specifications, etc.) Product Description SOL-SD-104076-4-0.1 SOL-DCD-104100-4-0.1 SOL-DPS-104019-4-0.1 SOL-ESH-104019-4-0.1 SOL-SD-104076-4-0.5 SOL-DCD-104100-4-0.5 SOL-DPS-104019-4-0 ...

Page 15

SOLARLOK Photovoltaic Interconnection System Combiner Box Product Features I Combines strings I Converts to standard wires I Completely pre-assembled I Plug and play design provides labor savings and minimizes installer error during installation I Uses existing ...

Page 16

... Wire Size Part Number 2 (mm ) 0-1394461-1 2.5 0-1394461-3 4.0 6-1394461-5 6.0 0-1394461-2 2.5 0-1394461-4 4.0 6-1394461-6 6.0 6-1394461-1 2.5 6-1394461-2 4.0 6-1394461-4 6.0 Wire Size Part Number 2 (mm ) 1740940-3 – 1740940-4 – Wire Size Part Number 2 ...

Page 17

... Male Cable Coupler (without Contact – only Housing and Sealing) Wire Size Part Number 2 (mm ) 1987286-4 – 1987286-5 – 1987286-6 – TÜV and UL pending. All dimensions are in millimeters unless otherwise specified. All specifications subject to change. Consult Tyco Electronics for latest specifications. Catalog 889753-3 Revised 9-2009 Package Keying Quantity ...

Page 18

... Parallel Interconnection using T-Branch Connector (Female-to-Male) Part Number 1740277-1 1740277-2 Safety + Clip (Optional Connector Latch Locking Clip Standard) Part Number 1534226-1 2106207-1 NEC/UL certified Part Number 1987423-1 for Female Cable Coupler 1394739-1 for Male Cable Coupler Catalog 889753-3 Keying Plus ...

Page 19

... All dimensions are in millimeters unless otherwise specified. All specifications subject to change. Consult Tyco Electronics for latest specifications. Package Keying Quantity Plus ...

Page 20

... Protection Degree: IP67 (mated) I No. of Positions: 5 Poles I Temperature Range: –40 ° +50 °C I Wire Size Range: 2 2.5–6 Approvals: • VDE certified Panel Mount Plug Part Number Free Hanging Receptacle Part Number Complete Sets Part Number 18 All dimensions are in millimeters unless otherwise specified. All specifications subject to change. ...

Page 21

... SOLARLOK Photovoltaic Interconnection System Field Wiring, Switching and Protection Product Features Switching I Modular product concept I One- / two-pole switches I Current Voltage up to 1,000 Compact, standardized design I Proven quality I TÜV and UL pending I One- / two-pole switch I Main switch function I Lockable I Current Voltage up to 1,000 V DC All dimensions are in millimeters unless otherwise specified ...

Page 22

... UV-radiation and to handle and to strip. ozone. Mechanical Features Electrical Features (according TÜV requirements) Voltage Rating: Max. Conductor Temperature 600/1,000 1,800 V DC Continuous: +125 °C Test Voltage for 5 Minutes: At Short Circuit: +200 °C Min. Operating Temperature Max. Current Carrying Capacity Free Installation: – ...

Page 23

... Part Number (AWG) 1986166-1 14 1986166-2 14 1986166-3 14 1986165-1 12 1986165-2 12 1986165-3 12 1986164-1 10 1986164-2 10 1986164 For other Cross Sections (1 400 mm All dimensions are in millimeters unless otherwise specified. All specifications subject to change. Consult Tyco Electronics for latest specifications. Outer Diameter (AWG) (mm) ± Toleranz 14 6.65 +0.15/–0. ...

Page 24

... Female Cable Coupler (–) 1394462-4 Female Cable Coupler (+) 1394462-3 Inverter Female Cable Coupler (–) 1394462-4 Female Cable Coupler (+) 1394462-3 Part Numbers for Cable Length 2-1987376-3 2-1987376-4 1-1987376-3 1-1987376-4 2-1987376-3 2-1987376-4 3-1987376-3 3-1987376-4 4-1987376-3 4-1987376-4 Revised 9-2009 2-1987376-5 1-1987376-5 2-1987376-5 3-1987376-5 4-1987376-5 ...

Page 25

... SolKlip for Solar Grounding (Part No. 1954381-x) to handle solid, un-insulated ground wire 2 from 4 mm (AWG 10). For larger wires from (AWG 8) and 16 mm (AWG 6) please use the AWG 6-8 Grounding Connector. Application Tooling No special tooling required. Insert ... Part Number Description 1954381-1 SolKlip with Self-Tapping Screw ...

Page 26

... Serial Interconnection for Junction Boxes with Cable Glands 1394462-4 1394461-4 1394462-4 1394738-4 24 All dimensions are in millimeters unless otherwise specified. All specifications subject to change. Consult Tyco Electronics for latest specifications. 2 (4.0 mm Wiring) 6-1394461-2 DC/AC Converter Catalog 889753-3 Revised 9-2009 1394462-3 1394462-3 1394738-3 ...

Page 27

... Serial Interconnection for Junction Boxes with Plug Connectors 1394462-4 1394462-3 1394462-4 1394738-4 All dimensions are in millimeters unless otherwise specified. All specifications subject to change. Consult Tyco Electronics for latest specifications. (continued) 2 (4.0 mm Wiring) 1394462-4 DC/AC Converter Catalog 889753-3 Revised 9-2009 1394462-3 1394462-3 1394738-3 25 ...

Page 28

... Consult Tyco Electronics for latest specifications. Catalog 889753-3 Revised 9-2009 Hand Crimping Tool for Screwed Contacts incl. Vario Crimp Head and Locator Part Numbers 2 1-1579004-1 (1 1-1579004-2 (4 Vario Crimp Head 2 7-1579001-8 (1 7-1579001-9 (4 Hand Crimping Tool for Stamped & Formed Contacts incl ...

Page 29

... Wire Spring Clamp Tool Part No. 1579007-2 Dioden / Jumper Spring Clamp Tool Part No. 1579007-5 Foil Spring Clamp Tool Part No. 1740969-3 5-Rail Box Part No. 1740969-1 Medium Box Part No. 1740969-2 Small Box Kit includes the following parts: I 100 Cable Coupler (Housings, Plus and Minus coded) I Crimp Contacts 2 (4 ...

Page 30

... Note: Strip Form is only suitable for processing with Applicator, Part No. 1855503-1. Catalog 889753-3 Revised 9-2009 Package Quantity 100 100 100 100 100 Package Quantity 100 100 100 100 100 Package Quantity 100 (Loose-Piece) 6,000 , , (Strip Form) Package Quantity 100 (Loose-Piece) 6,000 , , (Strip Form) ...

Page 31

... Part No. 1394465-4 The grommet has to be matched with the outer diameter of the solar cable (see customer drawing, Part No. 1394461 and Part No. 1394462) and the pinch ring (Part No. 1418677-2) must be applied. All dimensions are in millimeters unless otherwise specified. All specifications subject to change. ...

Page 32

SOLARLOK Photovoltaic Interconnection System Assembly and Installation Guidelines When assembling the connectors, the following sequence must be followed: 1 Stripping the Wire (please refer to application specification # 114-74013). 2 Insert the stripped wire into the wire crimp barrel until ...

Page 33

... All dimensions are in millimeters unless otherwise specified. All specifications subject to change. Consult Tyco Electronics for latest specifications. (continued disconnect the connector by pulling the connector halves apart. Catalog 889753-3 Fig. 5 (Female Connector) CAUTION: Do not disconnect the connector under load! Revised 9-2009 Fig ...

Page 34

... See Product Specification 108-18701 I 6. Tooling Find available tools for the contact crimping on page 26 (please specify required wire gauge extraction tool (Part No. 1102855-3) is needed to disassemble the connector components. This tool is used to unlock the contact retention features, after which the contact can be removed and re-used if necessary ...

Page 35

... Diameter 18 mm, (diameter 0.71 inch) –40 °C to +105 °C AWG 14, AWG 12, AWG 10 stranded wire IP 67, mated silver plated, 50, silver plated 30 – 40 Newton Coded housing ensures mating safety Contact voltage-proof Connector with crimp technology IEC 61215 Edition 2, 61646, IEC 61730, Protection Class II, UL 1703 33 ...

Page 36

... All dimensions are in millimeters unless otherwise specified. All specifications subject to change. ...

Page 37

... Disclaimer While Tyco Electronics and its affiliates referenced herein have made every reasonable effort to ensure the accuracy of the information contained in this catalog, Tyco Electronics cannot assure that this information is error free ...

Page 38

... RoHS Compliant Part numbers in this catalog are RoHS Compliant, unless marked otherwise. These products comply with European Union Directive 2002/95/EC as amended 1 January 2006 that restricts the use of lead, mercury, cadmium, hexavalent chromium, PBB, and PBDE in certain electrical and electronic products sold into the July 2006. ...

Page 39

... Fax: +52-55-1106-0901 +1-905-474-5525 For Latin/South American Countries not shown Phone: +54-11-4733-2015 +57-1-319-8960 Fax: +54-11-4733-2083 New Zealand – Auckland Phone: +64-9-634-4580 +81-44-812-3207 Fax: +64-9-634-4586 Philippines – Makati City Phone: +632-848-0171 +81-44-812-3200 Fax: +632-867-8661 People’s Republic of China Hong Kong +82-2-3486-3810 ...

Page 40

... Tyco Electronics AMP GmbH AMPèrestr. 12–14 64625 Bensheim / Germany Phone: +49-(0)6251-133-0 Fax: +49-(0)6251-133-1600 www.tycoelectronics.com SOLARLOK, SOLKLIP, TE Logo and Tyco Electronics are trademarks. © 2009 Tyco Electronics Ltd. 889753-3 Revised 9-2009 12M ST ...

Related keywords