... This specification covers performance, tests and quality requirements for the 3 mm Micro MATE-N- LOK* connector family. This connector family has wire-to-board and wire-to-wire configurations. The connectors are available positions in a double row configuration, and positions in a single row configuration, with both configurations using AWG wire. ...
Page 2
... Temperature: -40 to 105° C 3.4. Performance and Test Description Product is designed to meet the electrical, mechanical and environmental performance requirements specified in Figure 1. Unless otherwise specified, all tests shall be performed at ambient environmental conditions per EIA-364. 3.5. Test Requirements and Procedures Summary Test Description Initial examination of product ...
Page 3
... EIA-364-29. Apply an axial load of 1.4 kg [3.1 lb] to contacts at a rate of 0. lb] per second and hold for 6 seconds. EIA-364-29. Apply an axial load of 1. lb] to contacts at a rate of 0. lb] per second and hold for 6 seconds. ...
Page 4
... Measure axial force necessary to unmate specimens without locking latches at a maximum rate of 12.7 mm [.5 in] per minute. EIA-364-98. Determine housing lock strength at a maximum rate of 12.7 mm [.5 in] per minute. EIA-364-32, Test Condition VIII. Subject specimens to 5 cycles between -40 and 105° C. EIA-364-31, Method III. ...
Page 5
... Thermal shock Humidity/temperature cycling Temperature life Mixed flowing gas Final examination of product (a) See paragraph 4.1.A. NOTE (b) Numbers indicate sequence in which tests are performed. (c) Test omitted when testing wire-to-wire connectors. (d) The fourth test in this sequence will be either humidity/temperature cycling for tin plated specimens or mixed flowing gas for gold plated specimens ...
Page 6
... Acceptance Acceptance is based on verification that the product meets the requirements of Figure 1. Failures attributed to equipment, test setup or operator deficiencies shall not disqualify the product. If product failure occurs, corrective action shall be taken and specimens resubmitted for qualification. Testing to confirm corrective action is required before resubmittal ...
Page 7