Product data sheet
Characteristics
Complementary
Mar 31, 2012
Synchronisation time between inputs
Supply frequency
Power consumption in VA
Input protection type
Control circuit voltage
Line resistance
Breaking capacity
XPSAK351144
module XPSAK - Emergency stop - 120 V AC
Main
Range of product
Product or component
type
Safety module name
Safety module applica-
tion
Function of module
Safety level
Safety reliability data
Type of start
Connections - terminals
Output type
Number of additional
circuits
[Us] rated supply volt-
age
2 or 4 s depending of wiring (automatic start)
Unlimited (manual start)
50/60 Hz
<= 6 VA AC
Internal, electronic
24 V DC
28 Ohm
C300: 180 VA, AC-15 (holding) for relay output
C300: 1800 VA, AC-15 (inrush) for relay output
Preventa Safety automation
Preventa safety module
XPSAK
For emergency stop, switch, sensing mat/edges or
safety light curtain monitoring
Monitoring of electro-sensitive protection equipment
(ESPE)
Monitoring of a movable guard associated with 2
switches and automatic start
Monitoring of a movable guard
Emergency stop monitoring 1-channel wiring
Emergency stop with 2 NC contacts monitoring 2-
channel wiring
Multiple emergency stop monitoring 2-channel
wiring
Proximity sensor monitoring
Sensing mat and edges monitoring
Can reach PL e/category 4 conforming to EN/ISO
13849-1
Can reach SILCL 3 conforming to EN/IEC 62061
DC > 99 % conforming to EN/ISO 13849-1
MTTFd = 154.5 years conforming to EN/ISO
13849-1
PFHd = 7.39E-9 1/h conforming to EN/IEC 62061
Configurable
Captive screw clamp terminals (1 x 0.14...1 x 2.5
mm²)flexible cable with cable end, with double bezel
Captive screw clamp terminals (1 x 0.14...1 x 2.5
mm²)solid cable with cable end, with double bezel
Captive screw clamp terminals (1 x 0.25...1 x 1.5
mm²)flexible cable with cable end, with double bezel
Captive screw clamp terminals (1 x 0.25...1 x 2.5
mm²)flexible cable with cable end, with double bezel
Captive screw clamp terminals (2 x 0.14...2 x 0.75
mm²)flexible cable with cable end, with double bezel
Captive screw clamp terminals (2 x 0.14...2 x 0.75
mm²)solid cable with cable end, with double bezel
Captive screw clamp terminals (2 x 0.25...2 x 1
mm²)flexible cable with cable end, with double bezel
Captive screw clamp terminals (2 x 0.5...2 x 1.5
mm²)flexible cable with cable end, with double bezel
Relay instantaneous opening 3 NO, volt-free
1 NC + 4 solid state outputs
120 V AC (- 15...10 %)
24 V DC (- 15...10 %)
1