G6JU-2FS-Y-TR DC4.5 Omron, G6JU-2FS-Y-TR DC4.5 Datasheet - Page 4

SMT Tape & Reel Latching Relay

G6JU-2FS-Y-TR DC4.5

Manufacturer Part Number
G6JU-2FS-Y-TR DC4.5
Description
SMT Tape & Reel Latching Relay
Manufacturer
Omron
Series
G6J-Yr
Datasheet

Specifications of G6JU-2FS-Y-TR DC4.5

Relay Type
Telecom
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
1A @ 30VDC
Coil Type
Latching, Single Coil
Coil Current
22mA
Coil Voltage
4.5VDC
Control On Voltage (max)
3.38 VDC
Mounting Type
Surface Mount
Termination Style
Gull Wing
Contact Form
2 Form C
Power Consumption
100 mW
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G6JU-2FS-Y-TRDC4.5
G6JU2FSYTRDC45
Characteristic Data
60
Electrical Life Expectancy (with
Must Operate and Must Release
Voltage) (See note.)
Maximum Switching Capacity
Electrical Life Expectancy
Note:
0.7
0.5
0.3
0.1
1,000
100
10
500
300
100
80
60
40
20
7
5
3
1
50
30
10
0
5
3
1
0.001 0.01
1
0
Sample: G6J-2P-Y
Number of Relays: 10
Test conditions: 1-A resistive load at
30 VDC with an operation rate of 50%
Switching frequency: 1,800 operations/hour
125 VAC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
Operate voltage
1.
2.
DC resistive load
Release voltage
3
0.2
The tests were conducted at an ambient temperature of 23°C.
The contact resistance data are periodically measured reference values and are not values from each monitoring operation. Contact resistance values will vary according
to the switching frequency and operating environment, so be sure to check operation under the actual operating conditions before use
5
Surface-mounting Relay
10
0.1
Operating frequency (x10
0.4
30 50
30 VDC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
0.6
1
AC resistive load
Switching voltage (V)
100
Switching current (A)
10
0.8
3
300 500 1,000
100
operations)
1
max.
min.
max.
min.
1,000
1.2
Ambient Temperature vs. Must
Operate or Must Release Voltage
Ambient Temperature vs.
Maximum Voltage
G6J-Y
Electrical Life Expectancy
(Contact resistance) (See note.)
Note:
1,000
500
300
100
100
250
200
150
100
50
30
10
50
90
80
70
60
50
40
30
20
10
−40
−60
0
0
0.001 0.01
Sample: G6J-2P-Y
Number of Relays: 10
Test conditions: 1-A resistive load
at 30 VDC with an operation rate
of 50% Switching frequency:
1,800 operations/hour
“Maximum voltage” is the maximum voltage that can
be applied to the Relay coil.
Contact resistance
−40
−20
−20
0
Operating frequency (x10
0.1
0
20
1
20
Maximum estimated value
Ambient temperature (°C)
Ambient temperature (°C)
40
40
10
Operating voltage
Release voltage
60
60
NO contact
NC contact
3
operations)
100
max.
max.
min.
min.
80
80 100
1,000
max.
avg.
min.
max.
avg.
min.
100
Shock Malfunction
Shock directions
Conditions: Shock is applied in ±X, ±Y, and ±Z directions
three times each with and without energizing the Relays
to check the number of contact malfunctions.
Ambient Temperature
vs. Switching Current
1,000
Y'
Y
1,000
1,000
500
300
100
1.2
0.8
0.6
0.4
0.2
X
Contact Reliability Test
(See note.)
50
30
10
−40
1
0
Z'
X
0.001 0.01
Sample: G6J-2P-Y
Number of Relays: 10
Test conditions: 10 μA resistive load
at 10 m VDC with an operation rate
of 50% Switching frequency: 7,200
operations/hour
Contact resistance
X'
Z
Z'
−20
0
1,000
200
400
600
800
0.1
Operating frequency (x10
Y
Y'
20
1,000
800
600
400
200
1
Not
energized
Ambient temperature (°C)
Unit: m/s
Sample: G6J-2P-Y
Number of Relays: 10
40
Energized
10
60
2
1,000
1,000
NO contact
NC contact
5
Z
X'
100
operations)
80
max.
max.
min.
min.
1,000
100

Related parts for G6JU-2FS-Y-TR DC4.5