MKS1XTI-10 DC48 Omron, MKS1XTI-10 DC48 Datasheet
MKS1XTI-10 DC48
Specifications of MKS1XTI-10 DC48
Related parts for MKS1XTI-10 DC48
MKS1XTI-10 DC48 Summary of contents
Page 1
... Standard Built-in Operation Indicators Test Button Test Button and Built-in Operation Indicators MKS1XTIN-10 Note: 1. When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in the specifications. Example: MKS2XTIN-11 AC240 2. Refer to Terminal Arrangement and Internal Connections for all wiring diagrams. ...
Page 2
Specifications ■ Contact Ratings Models for DC Loads Contact form Model Load Resistive load Item Contact configuration NO NC Contact material Rated load 220 VDC NC Rated carry current NO NC Max. switching voltage NO NC Max. ...
Page 3
Coil Ratings Item Rated current (mA) Rated voltage ( 110 96.3 100 26.6 23.1 110 24.2 21.0 120 22.2 19.3 200 13.3 11.6 220 12.1 10.5 230 11.5 10.0 240 11.0 9.6 DC ...
Page 4
Approved Standards UL Recognized CSA Certified Model Coil ratings 12 to 220 VDC MKS1XT@-@ 24 to 240 VAC MKS2XT@-@ MKS1T@-@ MKS2T@-@ IEC Standard/TÜV Certification: IEC61810-1 (Certification No. R50104853) Model Coil ratings 12, 24, 48, 110, 220 VDC MKS1XT@-@ 24, ...
Page 5
Engineering Data Maximum Switching Power MKS1XT@-10 100 DC resistive load inductive load L 0.4 0.1 DC inductive load DC13 class 0. 100 1.000 Switching voltage (V) MKS1T@-10 100 ...
Page 6
... Operation Indicators MKS1XTIN-10 MKS2XTIN-11 Models for AC Loads Models with Test Button MKS1TI-10 MKS2TI-11 Models with Test Button and Built-in Operation Indicators MKS1TIN-10 MKS2TIN-11 Terminal Arrangement and Internal Connection (Bottom View) MKS1XT-10 MKS1XTN-10 MKS1XTI-10 MKS1XTIN-10 DC specification 4 6 (+) 4 6 (+) (+) B (− MKS1T-10 MKS1TN-10 MKS1TI-10 ...
Page 7
Connecting Socket Back-connecting Socket P7M-06P 43 max. 39 max. Front-connecting Socket P7MF-06 P7MF-06-D Dimensions 7 34 max. 78 max max. 24.3 Six Terminal Arrangement/Internal Connections Dimensions (Bottom View) 39 max 21.9 4.35 22.1 ...
Page 8
Hold-down Clip PYC-A2 One Set (Two Clips) 5 max. 42.8 4.5 4.5 1.2 Note: The minimum order for the PYC-A2 is ten clips. Socket Mounting Height P7M-06P P7MF-06 P7MF-06-D 8 General Purpose Power Relays 64 MK-S(X) 61 MK-S( ...
Page 9
Safety Precautions Be sure to read the precautions and information common to all electromechanical relays, contained in the Technical User’s Guide, “Electromechanical Relays, Technical Information” for correct use. Precautions for Correct Use Installation • Models for DC loads (i.e., models ...
Page 10
MEMO 10 General Purpose Power Relays MKS-X ...
Page 11
... Seller within 30 days of receipt of shipment. III. PRECAUTIONS 1. Suitability THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER’ ...
Page 12
... THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section. ...