Operating Procedures
■ Flow of Operation
■ Settings for Basic Functions
Changing the Mode
Programming Cams (Programming Mode)
Operation (Run Mode)
Setting Functions
Clearing Settings
Checking Timing (Test Mode)
Initial Settings
Setting Resolution and
Rotation Direction
Checking ON/OFF Angle Settings
Setting the ADV Function
Setting ON/OFF Angles
Disables all keys
and switches.
will light when the all
protection function is
enabled.
All Protection
Setting the Origin
PRG
RUN
PRG
RUN
PRG
RUN
TST
TST
TST
Refer to page 24.
ADV
5 s min.
Key
Advanced
Programming Mode
Test Mode
Run Mode
function
Changed with the mode switch.
Changed with the mode switch.
Parameters can be set in Function Setting Mode to perform more advanced operations.
➾ For details, refer to page 26 Advanced Functions.
Main Display: Angle
Sub-display: Speed
Main Display: Speed
Sub-display: Angle
Switching the Angle
and Speed Display
Advanced
Refer to page 24.
The Encoder resolution and rotation direction is set on a DIP switch.
➾ For details on the setting methods, refer to page 21.
The Encoder is mounted to the machine and the origin for operation is determined.
➾ For details on the setting methods, refer to page 21.
The machine is operated and outputs are actually made to check the timing of operation.
If the timing of operation is not correct, it can be changed.
➾ For details, refer to page 23.
Operation is started.
➾ For details, refer to page 24.
The ON/OFF angles that have been set can be checked.
➾ For details, refer to page 24.
Deletes settings. There are two methods that can be used to delete settings.
➾ For details, refer to page 25.
function
Clearing all programs (deletes all programming)
Clearing individual steps, cams, and banks
There are three methods that can be used to set or change ON/OFF angles (i.e., cam programming).
➾ For details on the setting methods, refer to pages 22 to 23.
1 s min.
ON/OFF
Using the ANGLE Keys (Manual Mode)
Actually turning the Encoder (Teaching Mode)
Setting from personal computer using Support Software (order separately)
PRG
RUN
TST
Key
Advance angle compensation (ADV) function can be set if required.
➾ For details on the setting methods, refer to page 27.
Programming Mode
Used to write cam programs, set the advance angle compensation
function, etc.
All outputs will remain OFF.
Test Mode
Used to write cam programs, set the advance angle compensation
function, and perform other operations while actually turning ON
outputs to confirm operation timing. This mode is also used to adjust
settings during operation.
Run Mode
Used for normal operation. Settings, such as writing cam programs
and setting the advance angle compensation function, cannot be
performed.