120SWUDC AMPERITE, 120SWUDC Datasheet
120SWUDC
Specifications of 120SWUDC
Related parts for 120SWUDC
120SWUDC Summary of contents
Page 1
Solving your relay requirements since 1922 SWUDC Series … Solid state CMOS digital circuitry … Four timing modes: Delay on operate; delay on release; TDR delay on operate & release; and interval or one-shot … DPDT (2 form C) isolated ...
Page 2
Solving your relay requirements since 1922 immediately. The timing cycle will begin when the external switch is opened. When the timing cycle is completed the relay contacts will release. The timing cycle may be reset to zero during the timing ...
Page 3
Solving your relay requirements since 1922 Outline Dimensions: Contact Information: Arrangement: 2 form C (DPDT) - Diagram C Contact Material: Silver - Cadmium Oxide Rating (Resistive): 10A @ 240V AC Resistive, 15A @ 30V DC Resistive, 15A @ 120V AC ...
Page 4
Solving your relay requirements since 1922 Input Voltages & Limits: Nominal Minimum Maximum 12V AC 10V 14V 24V AC 20V 28V 120V AC 105V 130V 12V DC 11V 14V 24V DC 20V 32V 48V DC 41V 55V 110V DC 95V ...
Page 5
... B) Divide the desired time delay (180 secs.) by the minimum time of the selected range. (minimum time in range secs.) 180/10 = 18. Always convert to the same time units (min., sec., hrs.) when dividing. C) The multiplier is equal to 1/2 of this quotient - 180/10 = 18. 18 therefore the multiplier for 180 seconds is 9 and the user must set switches S3 follows ...
Page 6
... User will have a time delay range of 72 secs - 360 secs. SWUDC Timing Mode Operating Instructions: The Amperite SWUDC Time Delay Relay operates in any one of four modes. These are user selectable by means of setting S8 and S9 of the nine positions Dip Switch. The modes and switch positions are as follows: ...
Page 7
... Close External Switch. Apply power. Relay contacts transfer immediately. At the end of the delay time the relay contacts release. Ordering Information: Definition of a part number for the Amperite SWUDC Series Time Delay Relay. Example: A: Denotes nominal input voltage. Voltages Available: 12V - AC or DC, 24V - AC or ...
Page 8
Solving your relay requirements since 1922 DC, 48V DC, 110V DC, 120V AC. Custom Voltages are available. B: For custom voltages only - denotes type of input current required for operation Alternating Current ...