D4BS-65FS Omron, D4BS-65FS Datasheet

no-image

D4BS-65FS

Manufacturer Part Number
D4BS-65FS
Description
SAFETY LIMIT SWITCH
Manufacturer
Omron
Datasheet
The Special Operation Key Activates a Direct
Opening Mechanism to Open the Contacts
and Shut Off Control Circuits when Protective
Doors Are Opened on Machine Tools or Other
Equipment
Model Number Structure
Model Number Legend
Switch
D4BS -
Ordering Information
List of Models
Switches (Operation Keys are sold separately.)
Consult with your OMRON representative when ordering any models that are not listed in this table.
• Conforms to EN (TÜV) standards corresponding to the CE marking.
• Certified by UL and CSA standards.
• The Switch contact is opened by a direct opening mechanism (NC
• Malfunctions and false operation prevented by special Operation Key.
• Wide temperature range specifications: −40 to 80°C.
• Degree of protection of the switch box: IP67 (EN60947-5-1).
• Series includes models with gold-plated contacts for handling the
1-conduit
3-conduit
1. Conduit
Safety-door Switch
D4BS
contacts only) when the protective cover is opened. The EN-certified
direct opening mechanism is indicated by
microload range.
1: PG13.5 (1 conduit)
2: G1/2 (1 conduit)
3: 1/2-14NPT (1 conduit)
4: M20 (1 conduit)
5: PG13.5 (3-conduit)
6: G1/2 (3-conduit)
7: 1/2-14NPT (3-conduit)
8: M20 (2-conduit)
Be sure to read the “Safety Precautions” on page 7 and the
“Precautions for All Safety Door Switches”.
Type
1
2
3
S
Front-side
mounting
Mounting direction
2. Built-in Switch
3. Head Mounting Direction
5: 1NC/1NO (slow-action)
6: 1NC/NO (slow-action), gold-plated contacts
A: 2NC (slow-action)
B: 2NC (slow-action), gold-plated contacts
F: Four mounting directions
possible (front-side mounting
at shipping)
on the Switch.
Conduit size
1/2–14NPT
1/2–14NPT
Pg13.5
Pg13.5
G1/2
G1/2
M20
M20
1NC/1NO (Slow-action)
Note: Contact your sales representative for details
: Models with certified direct opening contacts.
Note: An order for the head part or the switch
D4BS-15FS
D4BS-25FS
D4BS-35FS
D4BS-45FS
D4BS-55FS
D4BS-65FS
D4BS-75FS
D4BS-85FS
1. Operation Key Type
on models with safety standard certification.
Operation Key
D4BS - K
1: Horizontal mounting
2: Vertical mounting
3: Adjustable mounting (Horizontal)
part alone cannot be accepted. (The
Operation Key is sold separately.)
1
CSM_D4BS_DS_E_3_1
2NC (Slow-action)
D4BS-1AFS
D4BS-2AFS
D4BS-3AFS
D4BS-4AFS
D4BS-5AFS
D4BS-6AFS
D4BS-7AFS
D4BS-8AFS
1

Related parts for D4BS-65FS

D4BS-65FS Summary of contents

Page 1

... Note: An order for the head part or the switch part alone cannot be accepted. (The Operation Key is sold separately.) : Models with certified direct opening contacts. 1NC/1NO (Slow-action) 2NC (Slow-action) D4BS-15FS D4BS-1AFS D4BS-25FS D4BS-2AFS D4BS-35FS D4BS-3AFS D4BS-45FS D4BS-4AFS D4BS-55FS D4BS-5AFS D4BS-65FS D4BS-6AFS D4BS-75FS D4BS-7AFS D4BS-85FS D4BS-8AFS 1 ...

Page 2

... Model D4BS-K1 D4BS-K2 D4BS-K3 Certified Standards Certification body TÜV Rheinland UL CSA CQC (CCC) AC-15 Current (A) Make Break 1.5 12 1.2 D4BS Standard File No. EN60947-5-1 (certified direct J50084815 opening) GS-ET-15 UL508 E76675 CSA C22.2 No. 14 LR45746 GB14048.5 2003010305073833 Volt-amperes (VA) Make Break 7,200 720 2 ...

Page 3

... The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust, oil, or water penetration, do not use the D4BS in places where dust, oil, water, or chemicals may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur. ...

Page 4

... Structure and Nomenclature Structure Operation Key D4BS's exclusive-use Operation Key is provided to assure accurate switching operation. Set Zone Mark A triangular Set Zone Mark makes it easy to adjust the operating position when inserting the Operation Key. Built-in Switch A shearing force contact separating mechanism (NC contact) is employed, which positively pulls apart the ...

Page 5

... Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 2. There are fluctuations in the contact ON/OFF timing for 2NC contacts. Confirm performance before application. * The conduit thread varies with the model as follows: D4BS-1@@S, D4BS-5@@S: Pg 13.5 D4BS-2@@S, D4BS-6@@S: G1/2 D4BS-3@@S, D4BS-7@@S: 1/2-14NPT 31 ...

Page 6

... D4BS-1@@S + D4BS-K2 D4BS-2@@S + D4BS-K2 D4BS-3@@S + D4BS-K2 Red Operation Key insertion radius in horizontal direction: R ≥ 1200 54.5 min. 59 max. (40 ) ±0.15 (41) (13) Operation Key insertion radius in vertical direction: R ≥ 1000 54.5 min. ...

Page 7

... Head mounting screw M5 body mounting screw *2 Operation Key mounting screw Connector Cap screw *1. Apply a torque of 0.78 to 0.88 N·m if the D4BS is a three-conduit model. *2. Apply a torque of 4.90 to 5.88 N·m for an Allen-head bolt. For a Incorrect pan head screw, apply a torque of 2.35 to 2.75 N·m. ...

Page 8

... Operation Key Make sure that the Operation Key can be inserted properly with a tolerance of ±0 the upward, downward, left, or right direction. Otherwise the D4BS may soon become damaged due to misalignment. Observe the specified insertion radius for the Operation Key and insert direction perpendicular to the key hole. Do not use the D4BL operation key ...

Page 9

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords