NS5-MQ10-V2 Omron, NS5-MQ10-V2 Datasheet - Page 270
NS5-MQ10-V2
Manufacturer Part Number
NS5-MQ10-V2
Description
5 Mono Tchsrn, Serial+USB, Iv
Manufacturer
Omron
Datasheet
1.NS12-TS01B-V2.pdf
(334 pages)
Specifications of NS5-MQ10-V2
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
- Current page: 270 of 334
- Download datasheet (7Mb)
Appendix 1 Specifications
A-10
• Ethernet
Note 1. The default UDP port number is 9600.
Network address
Node address
UDP port number
IP address
Subnet mask
Default gateway
IP proxy address
Conversion table
Controller Link Specifications (with NS-CLK21 Controller Link Interface
Unit Mounted)
Communications method N:N token bus
Code
Modulation
Synchronization
Transmission path type
Baud rate and maximum
transmission distance
Media
Connections to nodes
Max. number of nodes
Communications func-
tions
Number of data link
words
Data link areas
Message length
RAS functions
Error correction
Note: A Controller Link Interface Unit can be used only for the NS15, NS12, and NS10 NS-
series PTs.
2. Do not set the following values for the IP address.
• Host ID with all bits set to 0 or 1.
• Net ID with all bits set to 0 or 1.
• Subnet ID with all bits set to 1.
• IP addresses that begin with 127.
Item
Item
1 to 127
1 to 254
1024 to 65535 (See note 1.)
0.0.0.0 to 255.255.255.255 (See note 2.)
0.0.0.0 to 255.255.255.255
0.0.0.0 to 255.255.255.255
“”(blank), 0.0.0.0 to 255.255.255.255
Node address: 1 to 253
IP address: 0.0.0.0 to 255.255.255.255
Manchester code
Baseband code
Flag synchronization (conforming to HDLC frames)
Multidrop (bus)
The maximum transmission distances depends on the baud rate setting as fol-
lows:
Specified shielded twisted-pair cable
2 signal lines and 1 shield
PLCs:
Personal computers: Connected via special connector (provided)
32 modes
Data links and message service
• Transmission area per node:
• Send/receive data link areas per SYSMAC CS-series PLC:
• Send/receive data link areas per SYSMAC C200HX/HG/HE, CVM1, or
• Send/receive data link areas per personal computer:
• Total send data link words on entire network:
Bit (CIO, and LR Area), data memory (DM Area), expansion data memory (EM
Area)
2,012 bytes max.
• Polling unit backup function
• Self-diagnosis (hardware check at startup)
• Internode tests and broadcast test (via FINS commands)
• Watchdog timer
• Error log
Manchester code check
CRC check (CCITT X
CV-series PLC:
2 Mbits/s: 500 m
1 Mbits/s: 800 m
500 Kbits/s: 1 km
1,000 words max. (2,000 bytes)
12,000 words max. (24,000 bytes)
8,000 words max. (16,000 bytes)
32,000 words max. (64,000 bytes)
32,000 words max. (64,000 bytes)
16
Connected via terminal block
+X
(Example: 192.168.21.0)
(Example: 255.255.21.16)
(Example: 192.168.255.16)
(Example: 127.35.21.16)
12
+X
5
Specifications
+1)
Specification
Related parts for NS5-MQ10-V2
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
5 Mono Tchsrn,Serial+USB,Bk 60
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
5 Mono ETN,Serial+USB,Bk 60
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
5 STN Color,Serial+USB,Bk 60M
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
5 STN Clr,ETN+Serial+USB,Bk 60
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
5 TFT Clr,Serial+USB,Bk 60M
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
5 TFT Clr,ETN+Serial+USB,Bk 60
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: