R88A-CNG01R Omron, R88A-CNG01R Datasheet - Page 259

no-image

R88A-CNG01R

Manufacturer Part Number
R88A-CNG01R
Description
Encoder Connector ABS Motor
Manufacturer
Omron
Datasheet

Specifications of R88A-CNG01R

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Terminal Block Wiring Procedure
1. Remove the Terminal Block from the Servo Drive before wiring.
2. Strip off 8 to 9 mm of the covering from the end of each wire.
3. Open the wire insertion slots in the Terminal Block
4. With the slot held open, insert the end of the wire.
5. Mount the Terminal Block to the Servo Drive.
Connector-type Terminal Blocks are used for Servo Drives of 1.5 kW or less (R88D-GTA5L to
GT15H). The procedure for wiring these Terminal Blocks is explained below.
The Servo Drive will be damaged if the wiring is done with the Terminal Block in place.
Refer to Terminal Block Wire Sizes on page 4-24 for applicable wire sizes.
There are two ways to open the wire insertion slots, as follows:
• Pry the slot open using the lever that comes with the Servo Drive (as in Fig. A).
• Insert a flat-blade screwdriver (end width: 3.0 to 3.5 mm) into the opening for the screwdriver, and
After inserting the wire, let the slot close by releasing the pressure from the lever or the screwdriver.
After all of the terminals have been wired, return the Terminal Block to its original position on the
Servo Drive.
press down firmly to open the slot (as in Fig. B).
Connector-type
Terminal Block
Fig. A
8 to 9 mm
(Example: R88D-GT01H)
Fig. B
4-2 Wiring
4-26
4

Related parts for R88A-CNG01R