E2EQ-X3D1 Omron, E2EQ-X3D1 Datasheet

PROX M12 PTFE 3MM DC2W-NO

E2EQ-X3D1

Manufacturer Part Number
E2EQ-X3D1
Description
PROX M12 PTFE 3MM DC2W-NO
Manufacturer
Omron
Series
E2EQr
Datasheet

Specifications of E2EQ-X3D1

Proximity Sensor Sensing Distance
3mm
Proximity Sensor Sensing Distance Range
2 to 7mm
Proximity Sensor Switching Mode
NO
Mounting
Panel
Operating Temp Range
-25C to 70C
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
10V
Operating Supply Voltage (typ)
12/15/18/24V
Operating Supply Voltage (max)
30V
Pin Count
2
Maximum Operating Temperature
+ 70 C
Operating Supply Voltage
10 V to 30 V
Sensing Distance
3 mm
Minimum Operating Temperature
- 25 C
Features
NO
Sensor Type
Inductive
Sensing Object
Metallic
Response Frequency
1kHz
Material - Body
Fluoroplastic Coated Brass
Shielding
Shielded
Voltage - Supply
10 V ~ 30 V
Output Type
NPN-NO
Terminal Type
3-Wire
Package / Case
Cylinder, Threaded - M12
Lead Free Status / Rohs Status
Compliant
Weld-Sputter Resistant DC 2-Wire
Cylindrical Sensors
H
H
H
H
Ordering Information
J PREWIRED MODELS
J PIGTAIL CONNECTOR SENSORS
J CONNECTOR CORDSETS
Sensing head
M12
M18
M30
Sensing head
M12
M18
M30
Connector type
3-wire DC
Micro change
Anti-spatter Inductive Prox
Rugged fluoroplastic coated brass
barrel withstands high tightening torque
Fluoroplastic resin face prevents weld
slag build up on sensor
Stability and operation indicators
standard
Prewired and pigtail connector models
g
R
Shielded
Shielded
Cable size
22 AWG
R
Length
2 m (6.5 ft)
5 m (16.4 ft)
10 m (32.8 ft)
Sensing distance
3 mm (0.12 in)
7 mm (0.28 in)
10 mm (0.39 in)
Sensing distance
3 mm (0.12 in)
7 mm (0.28 in)
10 mm (0.39 in)
Part number
Straight connector
Y96E-435D2
Y96E-435D5
Y96E-435D10
Output configuration
NO
Output configuration
NO
Part number
E2EQ-X3D1
E2EQ-X7D1
E2EQ-X10D1
Part number
E2EQ-X3D1-M1GJ
E2EQ-X7D1-M1GJ
E2EQ-X10D1-M1GJ
Right angle connector
Y96E-43RD2
Y96E-43RD5
Y96E-43RD10
E2EQ

Related parts for E2EQ-X3D1

E2EQ-X3D1 Summary of contents

Page 1

... Sensing distance Output configuration 3 mm (0.12 in (0.28 in (0.39 in) Part number Length Straight connector 2 m (6.5 ft) Y96E-435D2 5 m (16.4 ft) Y96E-435D5 10 m (32.8 ft) Y96E-435D10 E2EQ Part number E2EQ-X3D1 E2EQ-X7D1 E2EQ-X10D1 Part number E2EQ-X3D1-M1GJ E2EQ-X7D1-M1GJ E2EQ-X10D1-M1GJ Right angle connector Y96E-43RD2 Y96E-43RD5 Y96E-43RD10 ...

Page 2

... Note: The response frequencies for DC switching are average values measured on condition that the distance between each sensing object is twice as large as the size of the standard object and the sensing distance set is half of the maximum sensing distance. 2 E2EQ-X3D1 E2EQ-X7D1 E2EQ-X3D1-M1GJ E2EQ-X7D1-M1GJ Inductive M12 M18 ...

Page 3

... Brown 0 V Blue Load Note possible to connect the load in two ways as shown in the above diagrams. J TIMING CHART Non-sensing zone Sensing object (%) Rated sensing distance E2EQ DC DC Setting position Unstable sensing Stable sensing zone zone 100 80 0 Lit Green Indicator Not lit ...

Page 4

... J RESIDUAL OUTPUT VOLTAGE CHARACTERISTICS (TYPICAL) E2EQ-XjD1 Load current (mA) E2EQ-X7D1 X t Iron Stainless steel Brass Aluminum Copper Side length of sensing object (mm) E2EQ J LEAKAGE CURRENT CHARACTERISTICS (TYPICAL) E2EQ-X3D1 E2EQ-X10D1 E2EQ-X7D1 Supply voltage (V) E2EQ-X10D1 t Iron Stainless steel Brass Copper Aluminum Side length of sensing object (mm) ...

Page 5

... E2EQ Dimensions Unit: mm (inch) J SENSOR E2EQ-X3D1 21 dia. (0.83) 17 (0.67) E2EQ-X7D1 29 dia.(1.14) 24 (0.94) E2EQ-X10D1 42 dia.(1.65) 36 (1.42) E2EQ-X3D1-M1GJ 21 dia. (0.83) 17 (0.67) 38 (1.50) 27.6 (1.09) 24 (0.94) 5 Vinyl-insulated cable, 2 conductors, 6 dia. (45/0.12 dia.) Operation indicator 4 Standard length Two, clamping nuts M12 X 1 Cable extension (through a single metal Two, toothed washers conduit): 200 m max ...

Page 6

... Operation indicator Two, clamping nuts 4 M12 X 1 Two, toothed washers Models E2EQ-X3 E2EQ-X7 E2EQ-X10 E2EQ M12 x 1 (aluminum) Vinyl-insulated cable 6 dia. (45/0.12 dia.) Standard length: 0.3 m M12 x 1 (aluminum) Vinyl-insulated cable 6 dia. (45/0.12 dia.) Standard length: 0 (mm) +0.5 dia ...

Page 7

... J MUTUAL INTERFERENCE When installing two or more E2EQ face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained. A Model E2EQ-X3D1-j E2EQ-X7D1-j E2EQ-X10D1-j J SENSING OBJECT Part B Sensing Object Material Torque The sensing distance is reduced for non-magnetic metals. The --- sensing distance for non-magnetic metal foils less than 0 ...

Page 8

... Sensors in parallel, the leakage current through the load will be 0.8 mA times n, where n is the number of Proximity Sensors connected in parallel. J DIRECT CONNECTION TO A POWER SUPPLY Never connect the Proximity Sensor directly to a power supply without a load in the circuit. will be lower than L V ≤ E2EQ DC power supply AC power supply ...

Page 9

... One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. CEDSAX4A 11/01 (12/05) OMRON ON- -LINE Global - - http://www.omron.com USA - - http://www.omron.com/oei Canada - - http://www.omron.com/oci Specifications subject to change without notice. E2EQ OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Printed in U.S.A. ...

Related keywords