327913-000 Tyco Electronics, 327913-000 Datasheet - Page 487

no-image

327913-000

Manufacturer Part Number
327913-000
Description
Connector Accessories Hexa Shield Adapter Aluminum Alloy Olive Drab
Manufacturer
Tyco Electronics
Type
Hexa Shield Adapterr
Datasheet
Environmental Performance
Fire Hazard Performance
Catalog 1654025
Revised 12-04
www.tycoelectronics.com
Dimensions are in millimeters
and inches unless otherwise
specified. Values in brackets
are U.S. equivalents.
High Performance Wire and Cable
SPEC 44
Temperature Rating
SPEC 44 wire and cable is
rated for continuous opera-
tion from -65°C to +150°C
[-85°F to +302°F] and for
short periods at tempera-
tures as high as 300°C
[572°F]. Heat ageing tests
are routinely performed at
temperatures of 200°C
[392°F] (168 h) and 300°C
[572°F] (6 h). In addition
SPEC 44 insulation will not
shrink back under repeated
cycling.
Mechanical Performance
SPEC 44 wire provides bet-
ter cut through resistance
than some wires with much
thicker walls. 600 volt equip-
ment wire 44A0111 (0.19
mm wall) has 40% greater
cut through resistance than
600 volt PTFE insulated wire
(0.25 mm wall).
Smoke/Toxicity Index
Flammability
(Continued)
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
Solder Iron/Overload
Resistance
The radiation crosslinking
of the materials used in
SPEC 44 makes them non-
melting at high temperature.
As a result SPEC 44 wire is
resistant to prolonged con-
tact with solder irons and is
resistant to current over-
loads which would melt most
thermoplastic insulations.
Chemical Resistance
The irradiated dual wall
construction of SPEC 44
wire is highly resistant to
many acids, alkalis, hydro-
carbon solvents, fuels, lubri-
cants, water, and many
missile fuels and oxidizers.
Cold Flow
Radiation cross-linking of
SPEC 44 prevents cold flow
of the insulation — a recog-
nized problem of some
uncrosslinked materials.
Federal Aviation Reg FAR-25
BS4066 vertical flammability
S424 14751 (Swedish chimney)
NFC 32070 (2) (French chimney)
IEC 332 part 3 (Cable ladder)
Smoke Index, Def Stan 61-12 (18)
Toxicity Index, Def Stan 61-12 (18)
Oxygen Index, NES 714
Temperature Index, NES 715
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-5-729-0425
Voltage Ratings
Standard available voltage
ratings for SPEC 44 wire are
600 volts (0.19 mm wall
thickness), 1000 volts (0.28
mm wall) and 2500 volts
(0.48 mm wall).
Electrical Arc Track Resistance
SPEC 44 insulation demon-
strates a total resistance to
arc tracking under both wet
and dry conditions at air-
craft system voltages.
Low Outgassing
For use in space applica-
tions, special constructions
of SPEC 44 wire are avail-
able with low outgassing
characteristics, for use in an
environment of high vacuum
and high temperature.
South America: 55-11-3611-1514
Japan: 81-44-900-5102
Singapore: 65-4866-151
UK: 44-1793-528171
0.8 per meter of wire
6 per meter of wire
>300°C [572°F]
30% Oxygen
Pass
Pass
Pass
Pass
Pass
9-5
9