MT8812AE1 Zarlink, MT8812AE1 Datasheet
MT8812AE1
Specifications of MT8812AE1
Available stocks
Related parts for MT8812AE1
MT8812AE1 Summary of contents
Page 1
... Copyright 1997-2005, Zarlink Semiconductor Inc. All Rights Reserved. MT8812AE MT8812AP MT8812AP1 MT8812APR1 MT8812AE1 Description The Zarlink MT8812 is fabricated in Zarlink’s ISO- CMOS technology providing low power dissipation and high reliability. The device contains a 8 x12 array of crosspoint switches along with line decoder and latch circuits ...
Page 2
... Y4 Analog (Input/Output): this is connected to the Y4 column of the switch array. 22, 23 24,25 AX1,AX2 X1 and X2 Address Lines (Inputs). 24, 25 26,27 AY0,AY1 Y0 and Y1 Address Lines (Inputs). 26, 27 28- Connection. MT8812 VDD Y2 DATA X10 X3 14 X11 AY1 AY0 AX2 AX1 Y4 Figure 2 - Pin Connections Description 2 Zarlink Semiconductor Inc. Data Sheet PIN PLCC ...
Page 3
... The data can be changed while STROBE is high, however, the corresponding switch will turn on and off in accordance with the data. Data must be stable on the falling edge of STROBE in order for correct data to be written to the latch. MT8812 Description 3 Zarlink Semiconductor Inc. Data Sheet ...
Page 4
... V =14V unless otherwise stated ‡ Sym. Min. Typ. Max 100 ±1 ±500 I OFF 0.1 10 LEAK 4 Zarlink Semiconductor Inc. Data Sheet Min. Max. Units -0.3 16.0 -0.3 V +0.3 DD -0 -0 ±15 mA -65 +150 0.6 Units Test Conditions °C V ...
Page 5
... DC offset applied at the analog DC =0V, V =-7V, unless otherwise stated ‡ Sym. Min. Typ. Max 0 3dB THD 0.01 FDT -95 X -45 talk -90 -85 - Zarlink Semiconductor Inc. Data Sheet Units Test Conditions Ω =0V Ω 0. Ω See Appendix, Fig. A.2 Ω Ω =14V /2, DC ...
Page 6
... 100 100 R See Fig. 3 for control and I/O timing details. SPW 50% 50 50% 50 Figure 3 - Control Memory Timing Diagram 6 Zarlink Semiconductor Inc. Data Sheet Units Test Conditions mVpp V =3V+V squarewave =1kΩ, R =10kΩ See Appendix, Fig. A.6 pF f=1MHz 20 MHz 1kΩ, C =50pF ...
Page 7
... Zarlink Semiconductor Inc. Data Sheet AY2 Connection 0 X0-Y0 0 X1-Y0 0 X2-Y0 0 X3-Y0 0 X4-Y0 0 X5- Connection 0 No Connection 0 X6-Y0 0 X7-Y0 0 X8-Y0 0 X9-Y0 0 X10-Y0 0 X11- Connection 0 No Connection 0 X0-Y1 ↓ ↓ ↓ ...
Page 8
...
Page 9
...
Page 10
... Zarlink, or non-Zarlink furnished goods or services may infringe patents or other intellectual property rights owned by Zarlink. This publication is issued to provide information only and (unless agreed by Zarlink in writing) may not be used, applied or reproduced for any purpose nor form part of any order or contract nor to be regarded as a representation relating to the products or services concerned ...