1-1318301-2 TE Connectivity, 1-1318301-2 Datasheet
1-1318301-2
Specifications of 1-1318301-2
Available stocks
Related parts for 1-1318301-2
1-1318301-2 Summary of contents
Page 1
... Economy Power (EP) II Connector System used for wire-to-board interconnection and mates with EP headers. 1.2. Qualification When tests are performed on the subject product line, procedures specified in Figure 1 shall be used. All inspections shall be performed using the applicable inspection plan and product drawing. 2. APPLICABLE DOCUMENTS The following documents form a part of this specification to the extent specified herein ...
Page 2
... Current: See Figure 4 for applicable current carrying capability. Maximum rated current that can be carried by this product is limited by maximum operating temperature of the housings (105° C) and temperature rise of the housings (30° C). Variab les to be considered for each application are: wire size, connector size, contact material, ambient temperature, and printed circuit board design. ...
Page 3
... Mate and unmate specimens for 15 cycles at a maximum rate of 500 cycles per hour. EIA-364-13. Measure force necessary to mate specimens with latches disengaged at a maximum rate of 12.7 mm per minute. EIA-364-13. Measure force necessary to unmate specimens with latches disengaged at a maximum rate of 12.7 mm per minute ...
Page 4
... Durability Mating force Unmating force Crimp tensile Contact retention Thermal shock Humidity/temperature cycling Temperature life Final examination of product (a) See paragraph 4.1.A. NOTE (b) Numbers indicate sequence in which tests are performed. (c) Precondition specimens with 10 durability cycles. Rev O5 Test Group ( Test Sequence ( 3,7 2,6 ...
Page 5
... Acceptance Acceptance is based on verification that the product meets the requirements of Figure 1. Failures attributed to equipment, test setup or operator deficiencies shall not disqualify the product. If product failure occurs, corrective action shall be taken and specimens resubmitted for qualification. Testing to confirm corrective action is required before resubmittal ...
Page 6
... Multiplication Factor (F) from the above chart and multiply it times the Base rated Current for a single circuit at the maximum ambient operating temperature shown in Figure 4A. Rev O5 Figure 4A Current Carrying Capability Wire Size AWG 16 18 1.0 0.869 50 0.786 0.683 100 0.587 0.510 Figure 4B Current Rating 108-2297 20 22 0.767 0.685 0.603 0.538 0.450 0.402 ...