5-103635-4 TE Connectivity, 5-103635-4 Datasheet

Conn Shrouded Header HDR 5 POS 2.54mm Solder RA Thru-Hole Tube

5-103635-4

Manufacturer Part Number
5-103635-4
Description
Conn Shrouded Header HDR 5 POS 2.54mm Solder RA Thru-Hole Tube
Manufacturer
TE Connectivity
Type
Shrouded Headerr
Series
AMPMODU MTEr
Datasheet

Specifications of 5-103635-4

Pitch
2.54 mm
Number Of Rows
1
Number Of Contacts
5
Gender
HDR
Contact Plating
Gold Over Nickel
Termination Method
Solder
Connector Type
Wire To Board
Contact Termination
Right Angle Through Hole
No. Of Contacts
5
No. Of Rows
1
Pitch Spacing
2.54mm
Rohs Compliant
Yes
Product Type
Connector
Post Size (mm [in])
0.64 [.025]
Pcb Mounting Orientation
Right Angle
Termination Method To Wire/cable
Crimp, Insulation Displacement Crimp (IDC)
Pcb Mount Style
Through Hole
Pcb Mount Retention
Without
Connector Series
MTE
Contact - Rated Current (a)
3
Termination Resistance (m?)
15
Insulation Resistance (m?)
5,000
Dielectric Withstanding Voltage (v)
600
Solder Tail Contact Plating
Tin
Centerline (mm [in])
2.54 [0.100]
Row-to-row Spacing (mm [in])
2.54 [0.100]
Number Of Positions
5
Contact Type
Pin
Pcb Orientation Feature
No
Contact Plating, Mating Area, Material
Gold (15)
Contact Base Material
Brass
Contact Shape
Square
Connector Style
Plug
Mating Alignment
With
Mating Alignment Type
Latched
Housing Color
Black
Ul Flammability Rating
UL 94V-0
Housing Material
Thermoplastic - GF
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Wave solder capable to 240°C, Wave solder capable to 260°C, Wave solder capable to 265°C
Rohs/elv Compliance History
Always was RoHS compliant
Approved Standards
UL E28476, CSA LR7189
Operating Temperature (°c)
-65 – +105
Applies To
Printed Circuit Board
Packaging Method
Tube

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
5-103635-4
Manufacturer:
TE/泰科
Quantity:
20 000
Dual Entry, End Stackable,
Low Profile, .100 x .100
[2.54 x 2.54] Centerline,
.200 [5.08] Tine Spacing
Material and Finish
Housing — Glass-filled thermoplastic,
black, 94V-0 rated
Plating A — Duplex .000030 [0.00076]
gold on contact area, .000150-0.000300
[0.00381-0.00762] matte tin on solder
area all over .000050 [0.00127] nickel
Plating B — Duplex .000010
[0.000254] gold on contact area,
.000150-.000300 [0.00381-0.00762]
matte tin on solder area all over .000050
[0.00127] nickel
Plating C — .000150-.000300
[0.00381-0.00762] matte tin on solder
leads, all over .000050 [0.00127] nickel
Note: All part numbers are RoHS
Catalog 1307819
Revised 8-08
www.tycoelectronics.com
compliant.
are metric equivalents.
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
AMPMODU Interconnection System
Mod IV Receptacle Assemblies, Single-Row, Outrigger Design
.100 x .100 [2.54 x 2.54] Centerline, End To End Stackable
Notes: 1. Tyco Electronics recommends mating gold or duplex plated headers with duplex plated receptacle
(Standoffs)
No. of
Pos.
[3.56]
[0.51]
.140
.020
10
11
12
13
14
15
16
17
18
19
20
30
40
3
4
5
6
7
8
9
2. To obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to
assemblies.
the maximum point-of-contact dimension and add .062 [1.57] for recommended board thickness if used in
bottom entry application.
1.000 [25.40]
1.100 [27.94]
1.200 [30.48]
1.300 [33.02]
1.400 [35.56]
1.500 [38.10]
1.600 [40.64]
1.700 [43.18]
1.800 [45.72]
1.900 [48.26]
2.000 [50.80]
3.000 [76.20]
4.000 [101.60]
.300 [7.62]
.400 [10.16]
.500 [12.70]
.600 [15.24]
.700 [17.78]
.800 [20.32]
.900 [22.86]
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
A
[2.54]
.100
Typ.
[3.56]
.140
Dimensions
A
Recommended PC Board Hole Layout
1.000 [25.40]
1.100 [27.94]
1.200 [30.48]
1.300 [33.02]
1.400 [35.56]
1.500 [38.10]
1.600 [40.64]
1.700 [43.18]
1.800 [45.72]
1.900 [48.26]
2.900 [73.66]
3.900 [99.06]
.200 [5.08]
.300 [7.62]
.400 [10.16]
.500 [12.70]
.600 [15.24]
.700 [17.78]
.800 [20.32]
.900 [22.86]
B
.075 +.005
[
1.90
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-1106-0803
[0.89±0.08]
.035±.003
-.000
+0.13
-.000
]
[1.34]
.053
Typ.
B
5-147720-2
5-147720-3
5-147720-4
5-147720-5
5-147720-6
5-147720-7
5-147720-8
5-147720-9
6-147720-0
6-147720-1
6-147720-2
6-147720-3
6-147720-4
6-147720-5
6-147720-6
6-147720-7
6-147720-8
7-147720-8
8-147720-8
8-147720-9
Plating A
Dia.
[6.22]
.245
(Localized Gold
Plate Area)
[3.17±0.25]
.125±.010
Contact Plating/Part Nos.
[2.72]
.107
Typ.
[2.54]
[3.77]
.100
Typ.
.148
Typ.
5-147726-2
5-147726-3
5-147726-4
5-147726-5
5-147726-6
5-147726-7
5-147726-8
5-147726-9
6-147726-0
6-147726-1
6-147726-2
6-147726-3
6-147726-4
6-147726-5
6-147726-6
6-147726-7
6-147726-8
7-147726-8
8-147726-8
8-147726-9
Plating B
South America: 55-11-2103-6000
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-8706-080-208
[5.08]
.200
Point of
Contact
5-147727-2
5-147727-3
5-147727-4
5-147727-5
5-147727-6
5-147727-7
5-147727-8
5-147727-9
6-147727-0
6-147727-1
6-147727-2
6-147727-3
6-147727-4
6-147727-5
6-147727-6
6-147727-7
6-147727-8
7-147727-8
8-147727-8
8-147727-9
Plating C
[5.08±0.08]
.200±.003
Typ.
181
5

Related parts for 5-103635-4

5-103635-4 Summary of contents

Page 1

... Notes: 1. Tyco Electronics recommends mating gold or duplex plated headers with duplex plated receptacle assemblies obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to the maximum point-of-contact dimension and add .062 [1.57] for recommended board thickness if used in Note: All part numbers are RoHS bottom entry application ...

Page 2

... Notes: 1. Tyco Electronics recommends mating gold or duplex plated headers with duplex plated receptacle assemblies obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to the maximum point-of-contact dimension and .062 for recommended board thickness if used in bottom entry application ...

Page 3

... Notes: 1. Tyco Electronics recommends mating gold or duplex plated headers with duplex plated receptacle assemblies obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to Note: All part numbers are RoHS the maximum point-of-contact dimension, and .062 [1.57] for recommended board thickness if used in bot- compliant ...

Page 4

... Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Mod. IV Receptacle Assemblies, Double-Row, .100 x .100 [2.54 x 2.54] Centerline Dimensions No. of Pos 2.100 [53.34] 2.000 [50.80] 44 2.200 [55.88] 2.100 [53.34 ...

Page 5

... AMPMODU Interconnection System Mod IV Surface Mount Vertical Receptacle Assemblies, .100 x .100 [2.54 x 2.54] Centerline Product Facts ■ Surface Mount Leads ■ Contact Material: phosphor bronze ■ High temperature, black thermoplastic housings, 94V-0 rated, capable of withstanding IR or vapor- phase reflow Gold/tin duplex plating ■ ...

Page 6

... Dielectric Withstanding Voltage: 750 VAC Termination Resistance: 12 milliohms (max.) Insulation Resistance: 5000 megohms (min.) Mating Force (Receptacle Assemblies): 9.0 oz. [2.50N] (max.) per contact Unmating Force (Receptacle Assemblies): 1.5 oz. [0.42N] (min.) per contact Durability: Tested to 200 cycles (min.) for .000030 [0.00076] gold plated contacts Dimensions are shown for reference purposes only ...

Page 7

... Notes: 1. Tyco Electronics recommends mating gold or duplex plated headers with duplex plated receptacle assemblies obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to the maximum point-of-contact dimension, and .062 [1.57] for recommended board thickness if used in bottom entry application 3 ...

Page 8

... Notes: 1. Tyco Electronics recommends mating gold or duplex plated headers with duplex plated receptacle assemblies obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to the maximum point-of-contact dimension, and .062 [1.57] for recommended board thickness if used in bottom entry application. ...

Page 9

... Typ. area all over .000050 [0.00127] nickel Plating B — Duplex .000010 [0.000254] gold on contact area, .000150-.000300 [0.00381-0.00762] matte tin on solder area all over .000050 [0.00127] nickel Plating C — .000150-.000300 [0.00381-0.00762] matte tin on solder leads, all over .000050 [0.00127] nickel ...

Page 10

... Notes center holddown obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to the maximum point-of-contact dimension and .062 [1.57] for recommended board thickness in bottom entry applications. 5 190 ...

Page 11

... Plating B — Duplex .000010 [0.000254] gold on contact area, .000150-.000300 [0.00381-0.00762] matte tin on solder area all over .000050 [0.00127] nickel Plating C — .000150-.000300 [0.00381-0.00762] tin-lead over .000050 [0.00127] nickel [0.10] Related Product Data Mateable Headers — ...

Page 12

... Notes obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to the maximum point-of-contact dimension and .062 [1.57] for recommended board thickness in bottom entry applications. 5 192 Catalog 1307819 ...

Page 13

... Shrouded headers provide full pin protection ■ Polarized headers ■ Vertical headers available with ACTION PIN posts or .025 [0.64] square solder posts ■ Repairable ACTION PIN posts ■ Simple seating tooling for headers with ACTION PIN posts Recognized under the ■ ...

Page 14

... Mating Force — 8 oz. [2.22N] Termination Resistance — maximum per contact 12 milliohms max. at 100 milliamperes Unmating Force — .75 oz. [0.2N] test current, and 50 millivolts open cir- minimum per contact during third cuit voltage mating cycle Insulation Resistance — 1000 megohms after temperature/humidity ...

Page 15

... Notes: 1. .115 [2.92] tail length is for use with .062 [1.57] PC boards; .145 [3.68] tail length is for use with .093 [2.36] PC boards. Notes: 2. Receptacle assemblies with low force contacts are available, consult Tyco Electronics. 3. .256 [6.50] minimum positive pin stop to prevent shorting between rows. ...

Page 16

... Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Receptacle Assemblies, Board Mount, Double-Row, Closed Entry, .100 x .100 [2.54 x 2.54] Centerline .115 [2.92] .410 [10.41] B ±.008 [±0.20] .100 Typ. ...

Page 17

... AMPMODU Interconnection System Receptacle Assemblies, Board Mount, Triple-Row, Closed Entry, .100 x .100 [2.54 x 2.54] Centerline Horizontal Mount (with Guide Pin Slots and Standoffs) .179 Typ. [4.55] Material and Finish .338 Housing — Glass-filled thermoplastic, [8.59] black, 94V-0 rated .144 Contacts — Phosphor bronze, plated [3 ...

Page 18

... Tyco Electronics. 198 Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Headers, Straight Post, Double-Row, .100 x .100 [2.54 x 2.54] Centerline Pos. Ref .100 [2.54] .085 .200 [2.16] [5.08] B ...

Page 19

... Headers with ACTION PIN posts are for use with .093 [2.36] nominal or thicker PC boards. 2. Application tooling for installing headers with ACTION PIN posts is shown on pages 152 and 153. 3. Headers with .250 [6.35] tail length can be made available with make first/break last contacts, consult Tyco Electronics ...

Page 20

... Tyco Electronics. 200 Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Headers, Right-Angle Post, Double-Row, .100 x .100 [2.54 x 2.54] Centerline .762 Max. [19.35] .599 [15.21] .040 A [1.02] Typ. ...

Page 21

... AMPMODU Interconnection System Headers, Straight Post, Triple-Row, .100 x .100 [2.54 x 2.54] Centerline Solder Posts (with Pin Protection and Guide Pins) .100 [2.54] .100 [2.54] .085 [2.16] .040 [1.02] (4 Sides) Material and Finish Housing — Glass-filled thermoplastic, black, 94V-0 rated .210 [5.33] Posts — ...

Page 22

... Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Headers, VRM (Voltage Regulator Module), .100 x .100 [2.54 x 2.54] Centerline A B .110 [2.79] .440 [11.18] B .100 [2.54] .125 [3 ...

Page 23

... Shroud Board Mounted PC Board Straight Posts Typical Assembly Technical Documents — page 276 Double-Row, .100 x .100 [2.54 x 2.54] Centers Part No. 102114-1 Material — Black glass-filled polyester Note: All part numbers are RoHS compliant. Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified ...

Page 24

... Complete Cutoff (Right Side) Typical Barrier Insert Applications For Unshrouded Double-Row, Straight Post Headers, .100 x .100 [2.54 x 2.54] Centers See Fig. 3 See Fig. 4 Note: All configurations of barrier inserts compartmentalize headers and maintain polarization, except bar (Fig. 4) configuration, which is used primarily for compartmentalizing headers. ...

Page 25

... AMPMODU Interconnection System Accessories: Snap-In Polarizer for Low Profile Headers Material Black thermoplastic, flame retardant Part Numbers 499991-2 (Packaged 50 per bag) 499991-3 (Packaged 1000 per bag) Related Product Data Low Profile Headers used with — pages 135-140 Catalog 1307819 Dimensions are in inches and ...

Page 26

... Extraction housing Tool Slot Contact Clearance Hole *If post is longer than maximum specified, post tip may butt against wire ends. Dimension defines .025 x .025 [0.64 x 0.64] portion of post. Dimensions are shown for reference purposes only. Specifications subject to change. Left End Open (for ...

Page 27

... AMP-O-LECTRIC Model “G” machines (shown on page 270), as well as other bench machines and fully automatic AMPOMATOR lead making machines. Notes: 1. These contacts must be crimped in accordance with Tyco Electronics Specification No. 114-25006 in order to function properly in a connector housing. 2. Extraction Tool No. 91084-1 is used for removing individual contacts from connector housings and for detaching contacts from mating posts. ...

Page 28

... Product Specification 108-36028, 108-36028-1 Application Specification 114-25006 .125 [3.18] centerline single-row, 2 and 3 position housings are available, Base Part No. 104905. They are designed to be stackable end-to-end and side-by-side. Consult Tyco Electronics. 5 Keying Plug Part No. 87179-1 (Plugs directly into housings for .025 [0.64] square post contacts) Material — ...

Page 29

... AMPMODU Interconnection System Wire-Applied Housings for Locking Clip Contacts, Double-Row, .100 x .100 [2.54 x 2.54] Centerline Double-Row Material Glass-filled polyester, 94V-0 rated .270 [6.86] Related Product Data Contacts — page 207 Mateable Headers and Posts — Refer to the Mating Post Selection Guide — page 90 Technical Documents — ...

Page 30

... Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Mod IV Wire-Applied Contacts and Housings 1-87631-5 D-R Housing, Polarized with Detent 6-87756-6 Std. Pressure Contacts 102387-1 D-R Ejection Housing, Center Polarized 6-87756-6 Std. Pressure Contacts 1825851-1 Latch 5102154-1 Hdr ...

Page 31

... Plating B — Selectively plated .000015 *For use with AMP-O-LECTRIC Model “K” machines. Call the Technical Support Center (1-800-522-6752) for part nos. [0.00038] gold on contact area, with gold of applicators for use with the AMP-O-LECTRIC Model “G” machines (shown on page 270), as well as other bench flash over ...

Page 32

... Plating D — Selectively plated .000050 [0.00127] gold on contact area, with gold flash over .000050 [0.00127] nickel on entire contact Plating E — Selectively plated .000030 [0.00076] gold on contact area, with gold flash over .000050 [0.00127] nickel on entire contact Plating F — ...

Page 33

... Ph Bz **For use with AMP-O-LECTRIC Model “K” machines. Call the Technical Support Center (1-800-522-6752) for part nos. of applicators for use with the AMP-O-LECTRIC Model “G” machines (shown on page 270), as well as other bench machines and fully automatic AMPOMATOR lead making machines. ...

Page 34

... Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Mod IV Wire-Applied Housings, Single-Row, .100 [2.54] Centerline A Max. .050 ±.003 [1.27 [±0.08] Typ. .070 ...

Page 35

... AMPMODU Interconnection System Mod IV Wire-Applied Housings, Single-Row, .100 [2.54] Centerline Polarized (with Detent Latching) .175 [4.45] Material Black thermoplastic, flame retardant .071 Related Product Data [1.80] Contacts — pages 211-213 Mateable Headers and Posts — pages 115, 116 .056 Flexible Film Connectors, [1.42] Single-Row Pin Assemblies — ...

Page 36

... Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Mod IV Wire-Applied Housings, Double-Row, .100 x .100 [2.54 x 2.54] Centerline .175 [4.45] A .050 [1.27] B Typ No. ...

Page 37

... AMPMODU Interconnection System Mod IV Wire-Applied Housings, Double-Row, .100 x .100 [2.54 x 2.54] Centerline Polarized .175 [4.45] Material Black thermoplastic, flame retardant Related Product Data Contacts — pages 211-213 Mateable Headers and Posts— pages 117-131 Technical Documents — pages 277, 278 Product Specification 108-25007, 108-25019, 108-25020, No ...

Page 38

... Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Mod IV Wire-Applied Housings, Double-Row, .100 x .100 [2.54 x 2.54] Centerline .175 [4.45] A ±.003 ±.003 B C [±0.08] [±0.08] .100 Typ ...

Page 39

... AMPMODU Interconnection System Mod IV Wire-Applied Housings, Double-Row, .100 x .100 [2.54 x 2.54] Centerline No. of Pos **Cavity identification, part number and date code stamped on housing and/or strain relief where size permits. **No marking on housing or strain relief. Notes: 1. The Strain Relief/Pull Tab can be bonded to any thermoplastic connector housing. ...

Page 40

... Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Mod IV Wire-Applied Housings, Double-Row, .100 x .100 [2.54 x 2.54] Centerline Position No. 1 Indicator .130 [3.30 .120 C [3.05] X .227 [5 ...

Page 41

... AMPMODU Interconnection System Short Point, Crimp Snap-In Wire-Applied Contacts and Housings Product Facts Short point of contact ■ mates with .169 [4.29] to .259 [6.58] long post ■ Double-row housings are end-to-end and side-to-side stackable ■ Terminates 32-20 AWG [0.03-0 discrete wire ■ ...

Page 42

... Plating B — Duplex plated .000015 [0.00038] min. gold on contact area, .000050 [0.00127] min. tin in crimp area, with entire contact underplated .000050 [0.00127] min. nickel Plating C — .000100 [0.00254] min. tin over .000050 [0.00127] min. nickel on entire contact Related Product Data Performance Characteristics — ...

Page 43

... AMPMODU Interconnection System Short Point Wire-Applied Housings, Double-Row, Non-Polarized, .100 x .100 [2.54 x 2.54] Centerline Material Black thermoplastic, flame retardant, 94V-0 rated Related Product Data .049 [1.24] Performance Characteristics — page 221 Contacts — page 222 Mateable Headers — .100 pages 104, 105 [2 ...

Page 44

... Material Black thermoplastic, flame retardant, 94V-0 rated Related Product Data Performance Characteristics — page 221 Contacts — page 222 Mateable Headers — pages 104, 105, 135-138 Technical Documents — pages 276-278 Product Specification 108-1472 Application Specification 114-25038 5 224 Catalog 1307819 Dimensions are in inches and ...

Page 45

... Contact Termination Resistance — 15 milliohms (max.) Dielectric Withstanding Voltage — At Sea Level–600 VAC, rms At 70,000 Ft. [21 336 m]–225 VAC, rms Insulation Resistance — 5,000 megohms (min.) Environmental Characteristics Operating Temperature — -65°C to +105°C Vibration — ...

Page 46

... Receptacle Assemblies) 1 Mating AMPMODU Double-Row Shrouded Header Assemblies must have .318 [8.08] mating post length and .150 [3.81] dimension from centerline of last 1 post to inside of end shroud wall. Surface Mount Right-Angle and Vertical Headers are also available (see pages 251 and 252) ...

Page 47

... C. America: 52-55-1106-0803 Pin Contact, Insulation Displacement (Used in all Pin Assemblies) Pin Assemblies with Guide Ribs (See pages 238 & 239) Crimp Snap-In Pin Contact (Used with Unloaded Housings— See page 254) 5 227 South America: 55-11-2103-6000 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-8706-080-208 ...

Page 48

... Note: Insulation displacement contacts 5 accept an insulation diameter of .030 [0.76] min. to .054 [1.37] max. with an insula- tion wall thickness of .015 [0.38] max. Mating post length for preloaded housings is .200 [5.08] min., .250 [6.35] max. Related Product Data Mateable AMPMODU Products Breakaway Headers — ...

Page 49

... Tyco Electronics application machines, or manually when terminated with Tyco Electronics pistol grip hand tool. 2. Use Extraction/Lance Reset Tool No. 843477-1 to remove receptacle contacts. 3. Keying plugs are available, see page 253. Note: All part numbers are RoHS compliant. ...

Page 50

... Note: Insulation displacement contacts accept an insulation diameter of .030 [0.76] 5 min. to .054 [1.37] max. with an insula- tion wall thickness of .015 [0.38] max. Mating post length for preloaded housings is .200 [5.08] min., .250 [6.35] max. Related Product Data ...

Page 51

... Tyco Electronics application machines, or manually when terminated with Tyco Electronics pistol grip hand tool. 2. Use Extraction/Lance Reset Tool No. 843477-1 to remove receptacle contacts. 3. Keying plugs are available, see page 253. Note: All part numbers are RoHS compliant. ...

Page 52

... Note: Insulation displacement contacts accept an insulation diameter of .030 [0.76] 5 min. to .054 [1.37] max. with an insula- tion wall thickness of .015 [0.38] max. Mating post length for preloaded housings is .200 [5.08] min., .250 [6.35] max. Related Product Data Coupling Shrouds used with — ...

Page 53

... Tyco Electronics application machines, or manually when terminated with Tyco Electronics pistol grip hand tool. 2. Use Extraction/Lance Reset Tool No. 843477-1 to remove receptacle contacts. 3. Keying plugs are available, see page 253. Note: All part numbers are RoHS compliant. Catalog 1307819 ...

Page 54

... Note: Insulation displacement contacts accept an insulation diameter of .030 [0.76] min. to .054 [1.37] max. with an insulation wall thickness of .015 [0.38] max. Mating post length for preloaded housings is .200 [5.08] min., .250 [6.35] max. Related Product Data 5 Mateable AMPMODU Products Breakaway Headers — pages 102- 110, (with .230 mating length) Reeled Breakaway Headers — ...

Page 55

... Mateable AMPMODU Products (with Receptacle Assemblies Installed in Double-Row Coupling Shrouds) — No. of Headers, Shrouded, Double-Row Pos. (.318 [8.08] mating post length, .150 [3.81] end dimension) — 2 pages 119-121, 124, 125, 128, 129, 3 131-133 4 Application Tooling — page 273 5 Performance Specifications — 6 page 225 7 ...

Page 56

... Plating C — .000100 [0.00254] tin over .000050 [0.00127] nickel on entire contact 5 Note: Insulation displacement contacts accept an insulation diameter of .030 [0.76] min. to .054 [1.37] max. with an insula- tion wall thickness of .015 [0.38] max. Related Product Data Mateable AMPMODU Products — Receptacle Assemblies (Polarized/Latching) — ...

Page 57

... MTE Pin Assemblies, Shrouded—Individual Form Polarized/Latching, Single-Row, .100 [2.54] Centerline Individual Pin Assembly No. of Dimensions 30-26 AWG [0.05-0.15mm Pos. B ...

Page 58

... Note: Insulation displacement contacts 5 accept an insulation diameter of .030 [0.76] min. to .054 [1.37] max. with an insula- tion wall thickness of .015 [0.38] max. Related Product Data Mateable AMPMODU MTE Products (with Pin Assembly Installed in Panel Mount Pin Shroud) — ...

Page 59

... MTE Pin Assemblies—Individual Form with Guide Ribs, Single-Row, .100 [2.54] Centerline Individual Pin Assembly No. of Dimensions 30-26 AWG [0 ...

Page 60

... Mount Pin Shroud (Refer to pages 238, 239 & 242) Single-Row Coupling Shroud Headers, Polarized/Latching, Straight and Right Angle Post, with or without Holddown (See pages 244-252) USA: 1-800-522-6752 South America: 55-11-2103-6000 Canada: 1-905-470-4425 Hong Kong: 852-2735-1628 Mexico: 01-800-733-8926 Japan: 81-44-844-8013 C. America: 52-55-1106-0803 UK: 44-8706-080-208 ...

Page 61

... Ribs (Refer to pages 232, 233 & 235) 1 Mating AMPMODU Double-Row Shrouded Headers must have .318 [8.08] mating post length and .150 [3.81] dimension from centerline 1 of last post to inside of end shroud wall. Typical Application of Double-Row Coupling Shroud and Mating AMPMODU Products Note: All part numbers are RoHS compliant ...

Page 62

... USA: 1-800-522-6752 South America: 55-11-2103-6000 Canada: 1-905-470-4425 Hong Kong: 852-2735-1628 Mexico: 01-800-733-8926 Japan: 81-44-844-8013 C. America: 52-55-1106-0803 UK: 44-8706-080-208 .250 [6.35] Panel Mount Pin Shroud ...

Page 63

... Application Specification 114-25026 Receptacle Assemblies with Guide Ribs, Installed in Single-Row Coupling Shroud (Refer to pages 232, 233, 235 & 240) Typical Application of Panel Mount Pin Shroud and Mating AMPMODU Products Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified ...

Page 64

... Plating B — Duplex plated .000015 [0.00038] gold on contact area, .000100 [0.00254] min. tin on solder area, with entire post underplated .000050 [0.00127] nickel Plating C — .000100 [0.00254] tin over .000050 [0.00127] nickel on entire ...

Page 65

... 1.400 [35.56] 1.320 [33.53] 1.200 [30.48] 14 1.500 [38.10] 1.420 [36.07] 1.300 [33.02] 15 1.600 [40.64] 1.520 [38.61] 1.400 [35.56] 16 1.700 [43.18] 1.620 [41.15] 1.500 [38.10] 17 1.800 [45.72] 1.720 [43.69] 1.600 [40.64] 18 1.900 [48.26] 1.820 [46.23] 1.700 [43.18] 19 2.000 [50.80] 1.920 [48.77] 1.800 [45.72 ...

Page 66

... X .060 [1.52] .340±.003 .100* Typ. [8.64±0.08] [2.54] Recommended PC Board Hole Layout (PC board thickness (for Holddown Feature) is .062±.008 [1.57±0.20]) *±.003 [±0.08]; tolerance not to accumulate within one connector pattern. Without Holddown A B .060 [1.52] C .100 Typ. ...

Page 67

... Mexico: 01-800-733-8926 to change. C. America: 52-55-1106-0803 (Continued) Latching Header Without Hold Down Plating A Plating B Plating C 5-104935-5 5-103635-1 5-103634-1 5-104935-3 5-103635-2 5-103634-2 5-104935-1 5-103635-3 5-103634-3 5-104935-6 5-103635-4 5-103634-4 5-104935-7 5-103635-5 5-103634-5 5-104935-8 5-103635-6 5-103634-6 5-104935-2 5-103635-7 5-103634-7 5-104935-9 5-103635-8 5-103634-8 6-104935-0 5-103635-9 5-103634-9 6-104935-1 ...

Page 68

... Application Specification 114-25026 248 Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System MTE Headers, Shrouded Latching, Single-Row .100 [2.54] Centerline .535 [13.59] Position No. 1 Indicator A .060 [1.52 Plc.) C .120 X [3 ...

Page 69

... Material and Finish .060 Housing — Black thermoplastic, [1.52] 94V-0 rated Posts — Brass, duplex plated .000015 [0.00038] gold on contact area, .000100 [0.00254] min tin on solder tail, with entire post underplated .000050 .120 [0.00127] nickel [3.05] .060 [1.52] Related Product Data Mateable AMPMODU MTE Products — ...

Page 70

... Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System MTE Headers, Polarized/Latching, Through-Hole, Surface Mount Compatible, Single-Row, .100 [2.54] Centerline .535 [13.59] Position No. 1 Indicator A .060 B [1.52 Plc.) ...

Page 71

... K Plating B — Duplex plated .000015 [.00038] gold on contact area, .000100 [.00254] min. tin on solder area, with entire post underplated .000050 [.00127] nickel. Plating C — .000100 [.00254] tin over .262 [6.65] .000050 [.00127] nickel on entire post K Recommended PC Board Layout (Refer to MTE Application Spec. ...

Page 72

... Plating B — Duplex plated .000015 [.00038] gold on contact area, .000100 [.00254] min. tin on solder area, with entire post underplated .000050 [.00127] nickel. Plating C — .000100 [.00254] tin over .000050 [.00127] nickel on entire ...

Page 73

... Plating C *For use with Model “K” machines. Call the Technical Support Center (1-800-522-6752) for part nos. of applicators for use with the Model “G” machines (shown on page 270), as well as other bench machines and fully automatic AMPOMATOR lead making machines. ...

Page 74

... AMP-O-LECTRIC Model “K” machines. Call Technical Support Center (1-800-522-6752) for part nos. of applicators for use with the AMP-O-LECTRIC Model “G” machines (shown on page 270), as well as other bench machines and fully automatic AMPOMATOR lead making machines. ...

Page 75

... Max. Mating Force — High pressure - 26 oz. [7.23 N] Standard pressure - 9 oz. [2.50 N] Min. Unmating Force — High pressure — 5 oz. [1.39 N] Standard pressure — 1.5 oz. [0.417 N] Contact Retention in Housing — 5 lb. [22.24 N] per contact min. South America: 55-11-2103-6000 Hong Kong: 852-2735-1628 ...

Page 76

... Note: Contact Extraction/Lance Reset Tool No. 843477-3, see page 265. Part No. 87077-2 (Plugs directly into housing) Note: All part numbers are RoHS compliant. Dimensions are shown for reference purposes only. Specifications subject to change ...

Page 77

... Instruction Sheet *Cavity identification — first cavity (one side); Tyco Electronics Part No. and date code stamped on housing where size permits. 408-6532 Note: Contact Extraction/Lance Reset Tool No. 843477-3, see page 265. Keying Plugs Part No. 86286-1 (Plugs into receptacle contact) Part No. 87077-2 Material — ...

Page 78

... Technical Documents — pages 277, 278 Product Specification 108-25015, 108-25018, 108-25030 Application Specification 114-25032 Instruction Sheet 408-6532 Note: See page 259 for Low Profile Cover Part Nos. 5 258 Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www ...

Page 79

... Values in brackets www.tycoelectronics.com are metric equivalents Ejection Cover (Mates with AMP-LATCH universal ejection style pin headers equipped with latching ears, Part No. 102185-2 (with push tabs) or Part No. 102312-2 (without push tabs), see Tyco Electronics Catalog 82012. 1.120 Assembled* [28.45] Top View ...

Page 80

... Shields for right-angle headers have integral cantilever beams which provide good contact with the mating shielded MT receptacle assembly, without the use of a separate RF gasket. USA: 1-800-522-6752 South America: 55-11-2103-6000 Canada: 1-905-470-4425 Hong Kong: 852-2735-1628 Mexico: 01-800-733-8926 Japan: 81-44-844-8013 C. America: 52-55-1106-0803 UK: 44-8706-080-208 ...

Page 81

... Shield Ferrules — page 263 Technical Documents — pages 277, 278 Product Specification 108-25015, 108-25018, 108-25030 Application Specification 114-25032 Receptacle Assembly Purchased separately Instruction Sheet (Refer to pages 256 & 257) 408-6532 No. of Pos Note: Match shield size to number of connector positions. Note: All part numbers are RoHS compliant. ...

Page 82

... Note 2) Outer Shell Half Ferrule Purchased separately (See page 263) Flare braid over assembled shells for crimping under ferrule Standard MT Receptacle Assembly Purchased separately (Refer to pages 256 & 257) Inner Shell Half Dimensions No. of Pos 1.010 [25.65] 1.120 [28.45] 26 1.410 [35.81] 1 ...

Page 83

... Model “K” machines. Call the Tyco Electronics Technical Support Center (1-800-522-6752) for part nos. of applicators for use with the AMP-O-LECTRIC Model “G” machines (also shown on page 270), as well as other bench machines and fully automatic AMPOMATOR lead making machines. ...

Page 84

... D ±.003 [±0.08] [2.54±0.08] ±.003 2D [±0.08] Recommended PC Board Hole Layout for 6, 8 and 10 Positions D - Contact centerline is .100 [2.54]; ±.003 [0.08] tolerances not to accumulate within one connector pattern. Dimensions No. of Pos .200 [5.08] .430 [10.92] 8 ...

Page 85

... AWG Application Tooling — 30-26 pages 273-275 26-22 22-20 Technical Documents — Note: Termination tooling for MT receptacle insulation displacement contacts is shown on pages 273-275. pages 277, 278 Product Specification 108-25015, 108-25018, 108-25030 Application Specification 114-25032 Instruction Sheet 408-6532 MT receptacle contacts incorporate the following features ...

Page 86

... When used row housings with .100 individually, they will mate [2.54] centerline spacing. with posts as short as .125 Single-row housings can be [3.18] and when used in a converted into double-row housing, they will mate with connectors on .100 x .200 ...

Page 87

... Max. A Max. [2.54] .050 .100 [2.54] [1.27] B Spaces @ .100 [2.54 Minimum mating post length is .140 [3.55]. Dimensions A B .200 [5.08] 1 .400 [10.16] 3 .800 [20.32] 7 1.200 [30.48] 11 1.600 [40.64] 15 1.800 [45.72] 17 2.000 [50.80 ...

Page 88

... AMPMODU Interconnection System Mini-Tandem Spring Housings, Double-Row .550 [13.97] A Max. .200 [5.08] .100 [2.54] B Spaces @ .100 [2.54 Minimum mating post length is .140 [3.55]. Dimensions No. of Pos .300 [7.62] 8 .400 [10.16] 12 .600 [15.24] 16 .800 [20.32] Note: Mini-Tandem Spring contacts for use in these housings are shown on page 269. ...

Page 89

... Notes: 1. Mini-Tandem Spring Receptacle Contacts are for use only in the housings shown on pages 267 & 268. They cannot be used in AMPMODU Mod IV Housings. 2. Use Hand Tool No. 91540-1 for crimping loose-piece receptacles to all wire sizes listed above. 3. Application tooling is described on pages 270 & 275. ...

Page 90

... By performing maintenance at measured intervals with pre-set limits, operators avoid breakdowns and rejects caused by tool wear or mid-adjustment. For more information, request catalog 1773385. USA: 1-800-522-6752 South America: 55-11-2103-6000 Canada: 1-905-470-4425 Hong Kong: 852-2735-1628 Mexico: 01-800-733-8926 Japan: 81-44-844-8013 C. America: 52-55-1106-0803 UK: 44-8706-080-208 ...

Page 91

... Optional Stripping Module for the AMP 3K/40, AMP 5K/40 and the AMP-O-LECTRIC Model G The combination of the Stripping Module with the AMP-O-LECTRIC Model G Terminator or the AMP ...

Page 92

... For further details on Tyco Electronics straight action hand tools, request Tyco Electronics Catalog 65780. For more details on Tyco Electronics pneumatic tooling assemblies, call the Tyco Electronics Technical Support Center, 1-800-522-6752. USA: 1-800-522-6752 South America: 55-11-2103-6000 ...

Page 93

... Modular Heads: 58062-1 (for MT connectors) 58336-1 (for MTE connectors) *A tube-fed track assembly, Part No. 856675-1, also can be used with MTE Connectors. 273 South America: 55-11-2103-6000 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-8706-080-208 ...

Page 94

... The feed track is a constant force, *At a rate of 13-25 positions at a time. 2700 lb. Power Unit With Cable Notching Die Equipped with a cable notching die an adapter kit, this fully pneumatic bench ...

Page 95

... AMPMODU Interconnection System Application Tooling for Insulation Displacement Crimp (IDC) Contacts and Connectors Tooling shown on this page CHAMPOMATOR Model 2.5 Terminating Machine No. 354786-(*) is designed to terminate IDC contacts for various AMPMODU wire-to-board connectors. Refer to page 88 to determine the applica- ble connectors. This compact bench ...

Page 96

... Receptacle Assemblies, Horizontal and Vertical Board Mount — Pages 168-192: 114-25018 AMPMODU Mod. II and IV Receptacle Assembly, PC Board Mounted, Vertical, Application of .025 [0.64] Square Posts, Headers, Accessories and Tooling — Pages 92-105, 114-140, 145-153, 163-167: 114-25028 ACTION PIN Contacts with Tyco Electronics Headers, Application 114-13011 AMPMODU ...

Page 97

... Short-Point Wire-Applied Contacts and Housings — Pages 221-224: 114-25038 AMPMODU MTE Interconnection System — Pages 225-252: 114-25026 AMPMODU MT and Shielded MT Interconnection System — Pages 255-265: 114-25032 AMPMODU Level V, IDC Connectors — 114-25020 Mini-Tandem Spring Receptacle Contacts — Pages 266-269: 114-25021 Note: All part numbers are RoHS compliant ...

Page 98

... Tyco Electronics Extraction Tools 843996 and 843477 for Removing AMPMODU Crimp Snap-In Receptacle Contacts from Wire-Applied Housings 408-9515 Ribbon Cable Notcher 854449-[] AMPMODU MT and Shielded MT Interconnection System — Pages 255-265: 408-6532 AMPMODU MT Connectors AMPMODU Level V, IDC Connectors — 408-6843 Tyco Electronics Extraction Tool 91409-1 Standard Tandem Spring and Mini-Tandem Spring Receptacle Contacts — ...

Related keywords