ISP1760ET,557 NXP Semiconductors, ISP1760ET,557 Datasheet - Page 81

no-image

ISP1760ET,557

Manufacturer Part Number
ISP1760ET,557
Description
Manufacturer
NXP Semiconductors
Datasheet

Specifications of ISP1760ET,557

Package Type
TFBGA
Pin Count
128
Lead Free Status / RoHS Status
Compliant
NXP Semiconductors
Table 78.
ISP1760_4
Product data sheet
Bit
DW7
63 to 40
39 to 32
DW6
31 to 24
23 to 16
15 to 8
7 to 0
DW5
63 to 56
55 to 48
47 to 40
39 to 32
DW4
31 to 29
28 to 26
25 to 23
22 to 20
19 to 17
16 to 14
13 to 11
Symbol
reserved
INT_IN_7[7:0]
INT_IN_6[7:0]
INT_IN_5[7:0]
INT_IN_4[7:0]
INT_IN_3[7:0]
INT_IN_2[7:0]
INT_IN_1[7:0]
INT_IN_0[7:0]
Status7[2:0]
Status6[2:0]
Status5[2:0]
Status4[2:0]
Status3[2:0]
Status2[2:0]
Status1[2:0]
Start and complete split for interrupt: bit description
SCS[7:0]
Access
-
HW — writes
HW — writes
HW — writes
HW — writes
HW — writes
HW — writes
HW — writes
HW — writes
SW — writes
(0
HW — writes
(1
After
processing
HW — writes
HW — writes
HW — writes
HW — writes
HW — writes
HW — writes
HW — writes
1)
0)
Value
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Rev. 04 — 4 February 2008
Description
-
Bytes received during SOF7, if SA[7] is set to 1 and frame
number is correct. The new value continuously overwrites the old
value.
Bytes received during SOF6, if SA[6] is set to 1 and frame
number is correct. The new value continuously overwrites the old
value.
Bytes received during SOF5, if SA[5] is set to 1 and frame
number is correct. The new value continuously overwrites the old
value.
Bytes received during SOF4, if SA[4] is set to 1 and frame
number is correct. The new value continuously overwrites the old
value.
Bytes received during SOF3, if SA[3] is set to 1 and frame
number is correct. The new value continuously overwrites the old
value.
Bytes received during SOF2 (bits 7 to 0), if SA[2] is set to 1 and
frame number is correct. The new value continuously overwrites
the old value.
Bytes received during SOF1, if SA[1] is set to 1 and frame
number is correct. The new value continuously overwrites the old
value.
Bytes received during SOF0 if SA[0] is set to 1 and frame
number is correct. The new value continuously overwrites the old
value.
All bits can be set to one for every transfer. It specifies which SOF
the complete split needs to be sent. Valid only for IN. Start split and
complete split active bits, SA = 0000 0001, SCS = 0000 0100,
will cause SS to execute in Frame0 and CS in Frame2.
Interrupt IN or OUT status of SOF7
Interrupt IN or OUT status of SOF6
Interrupt IN or OUT status of SOF5
Interrupt IN or OUT status of SOF4
Interrupt IN or OUT status of SOF3
Interrupt IN or OUT status of SOF2
Interrupt IN or OUT status of SOF1
Embedded Hi-Speed USB host controller
© NXP B.V. 2008. All rights reserved.
ISP1760
80 of 110

Related parts for ISP1760ET,557