FW82801EB Intel, FW82801EB Datasheet - Page 513

no-image

FW82801EB

Manufacturer Part Number
FW82801EB
Description
Manufacturer
Intel
Datasheet

Specifications of FW82801EB

Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FW82801EB
Manufacturer:
INTEL
Quantity:
20 000
Part Number:
FW82801EB SL73Z
Manufacturer:
INTEL
Quantity:
238
Part Number:
FW82801EB(SL73Z)
Manufacturer:
INTEL
Quantity:
20 000
Intel
®
82801EB ICH5 / 82801ER ICH5R Datasheet
NOTES:
1. Software should do Read-Modify-Write operations to this register to preserve the contents of bits not being
2. To preserve the usage of RESERVED bits in the future, software should always write the same value read
15:12
Bit
9:7
3:0
modified. This include Reserved bits.
from the bit until it is defined. Reserved bits will always return 0 when read.
11
10
6
5
4
LINK_ID_STS — RO. This field identifies the link interface.
0h = Hardwired. Indicates that it is a USB Debug Port.
Reserved. This bit returns 0 when read. Writes have no effect.
IN_USE_CNT — R/W. Set by software to indicate that the port is in use. Cleared by software to
indicate that the port is free and may be used by other software. This bit is cleared after reset. (This
bit has no affect on hardware.)
EXCEPTION_STS — RO. This field indicates the exception when the ERROR_GOOD#_STS bit is
set. This field should be ignored if the ERROR_GOOD#_STS bit is 0.
000 =No Error. (Default)
001 =Transaction error: indicates the USB 2.0 transaction had an error (CRC, bad PID, timeout,
010 =Hardware error. Request was attempted (or in progress) when port was suspended or reset.
All Other combinations are reserved
ERROR_GOOD#_STS — RO.
0 = Hardware clears this bit to 0 after the proper completion of a read or write. (Default)
1 = Error has occurred. Details on the nature of the error are provided in the Exception field.
GO_CNT — WO.
0 = Hardware clears this bit when hardware sets the DONE_STS bit. (Default)
1 = Causes hardware to perform a read or write request.
NOTE: Writing a 1 to this bit when it is already set may result in undefined behavior.
WRITE_READ#_CNT — R/W. Software clears this bit to indicate that the current request is a read.
Software sets this bit to indicate that the current request is a write.
0 = Read (Default)
1 = Write
DATA_LEN_CNT — R/W. This field is used to indicate the size of the data to be transferred.
default = 0h.
For write operations, this field is set by software to indicate to the hardware how many bytes of data
in Data Buffer are to be transferred to the console. A value of 0h indicates that a zero-length packet
should be sent. A value of 1–8 indicates 1–8 bytes are to be transferred. Values 9–Fh are illegal
and how hardware behaves if used is undefined.
For read operations, this field is set by hardware to indicate to software how many bytes in Data
Buffer are valid in response to a read operation. A value of 0h indicates that a zero-length packet
was returned and the state of Data Buffer is not defined. A value of 1–8 indicates 1–8 bytes were
received. Hardware is not allowed to return values 9–Fh.
The transferring of data always starts with byte 0 in the data area and moves toward byte 7 until the
transfer size is reached.
Note: this should not be seen, since this field should only be checked if there is an error.
etc.)
Description
EHCI Controller Registers (D29:F7)
513