LSISAS1064E LSI, LSISAS1064E Datasheet

no-image

LSISAS1064E

Manufacturer Part Number
LSISAS1064E
Description
Manufacturer
LSI
Datasheet

Specifications of LSISAS1064E

Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LSISAS1064E
Manufacturer:
ST
Quantity:
2 241
Part Number:
LSISAS1064E
Manufacturer:
LSI
Quantity:
996
Part Number:
LSISAS1064E
Manufacturer:
LSI
Quantity:
20 000
Company:
Part Number:
LSISAS1064E
Quantity:
2 833
Part Number:
LSISAS1064E B1
Manufacturer:
LSI
Quantity:
110
Part Number:
LSISAS1064E B1
Manufacturer:
LSI/PBF
Quantity:
654
Part Number:
LSISAS1064E B1
Manufacturer:
LSILOGI
Quantity:
20 000
Company:
Part Number:
LSISAS1064E B1
Quantity:
798
Part Number:
LSISAS1064E B3
Manufacturer:
LSI
Quantity:
59
Part Number:
LSISAS1064E B3
Manufacturer:
LSI
Quantity:
147
Part Number:
LSISAS1064E B3
Manufacturer:
LSI
Quantity:
20 000
Part Number:
LSISAS1064E-B3
Quantity:
3
LSISAS1064E PCI Express to 4-Port
Serial Attached SCSI Controller
Datasheet
Version 2.0
DB08-000275-03
Version 2.0
The LSISAS1064E is a four-port, 3.0 Gbit/s SAS/SATA controller that is
compliant with the Fusion-MPT
architecture, provides an eight-lane PCI Express interface, and supports
Integrated RAID
compatible with previous revisions of the PCI bus and PCI-X bus. The
LSISAS1064E supports the PCI Express Base Specification, Revision
1.0a, and the ANSI Serial Attached SCSI Standard, Revision 1.1.
Figure 1
The point-to-point interconnect feature of the PCI Express bus limits the
electrical load on links, allowing increased transmission and reception
frequencies. The PCI Express transmission and reception data rates for
each full-duplex interconnect is 2.5 Gbits/s. The LSISAS1064E has eight
PCI Express phys, which provide host-side possible maximum
transmission and reception rates of 4.0 Gbytes/s. The LSISAS1064E
supports x8, x4, and x1 PCI Express link widths, and automatically
downshifts if plugged into either a x4 connector or into a x8 connector
that is wired as a x4 connector. The serial PCI Express interconnect
between devices lowers the number of pins per device, which reduces
both the PCI Express board design costs and the overall board design
complexity. The serial connection also makes the PCI Express
performance highly scalable.
Figure 1
May 2006
Copyright © 2004–2006 by LSI Logic Corporation. All rights reserved.
PCI Express to SAS Controller
PCI Express Interface
and
LSISAS1064E
LSISAS1064E Direct-Connect Example
Figure 2
SAS/SATA
Drives
8
technology. The PCI Express software is backward
provide examples of LSISAS1064E applications.
32-bit Memory
Address/Data
(Message Passing Technology)
Interface
Serial
Bus
Flash ROM/
NVSRAM
I
2
C
1 of 30

Related parts for LSISAS1064E

LSISAS1064E Summary of contents

Page 1

... LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller Datasheet Version 2.0 The LSISAS1064E is a four-port, 3.0 Gbit/s SAS/SATA controller that is compliant with the Fusion-MPT architecture, provides an eight-lane PCI Express interface, and supports Integrated RAID compatible with previous revisions of the PCI bus and PCI-X bus. The LSISAS1064E supports the PCI Express Base Specifi ...

Page 2

... This keeps the device pin count low and reduces the system cost. Each of the four SAS phys on the LSISAS1064E is capable of SAS/SATA link rates of 3.0 Gbits/s and 1.5 Gbits/s. The user can configure ports as wide or narrow. Narrow ports have one phy per port. Wide ports have two, three, or four phys per port ...

Page 3

... SCSI. SAS controllers leverage an electrical and physical connection interface that is compatible with SATA technology. The LSISAS1064E supports the Integrated RAID solution, which is a highly integrated, low cost RAID implementation designed for systems requiring redundancy and high availability, but not needing a full-featured RAID implementation ...

Page 4

... Supports x8, x4, and x1 link widths Automatically downshifts link width if plugged into a x4 connector or into a x8 connector that is wired connector LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 Copyright © 2004–2006 by LSI Logic Corporation. All rights reserved. ...

Page 5

... Supports Message Signaled Interrupts (both MSI and MSI-X) as well as INTx interrupt signaling for legacy PCI support Supports end-to-end CRC (ECRC) and Advanced Error Reporting LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 Single-lane aggregate bandwidth 0.5 Gbytes/s (500 Mbytes/s) Quad-lane aggregate bandwidth ...

Page 6

... Allows mixed connections to SAS or SATA targets Allows a grouping four phys in a wide port Leverages compatible connectors for SAS and SATA connections LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 Single driver binary for SAS/SATA, Ultra320 SCSI, and Fibre Channel products One fi ...

Page 7

... LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 ® transceivers on both the SAS/SATA phys ® ® Multi-ICE technology for debugging the ARM966 provides the block diagram for the LSISAS1064E. The following Copyright © 2004–2006 by LSI Logic Corporation. All rights reserved ...

Page 8

... I C Host Interface Module The LSISAS1064E interfaces with the host through the host interface module. The host interface module contains the PCI Express interface, system interface, IOP (ARM966) processor, timer and configuration, DMA arbiter, PCI timer and configuration, SIO, external memory, I UART blocks ...

Page 9

... GPIO signals. This block also supports internal timing adjustments and power-on sense configuration options. DMA Arbiter The LSISAS1064E provides the ability to transfer system memory blocks to and from local memory through the descriptor-based DMA arbiter and router. The DMA channel includes a system DMA FIFO and the internal bus interface logic. PCI Timer and Confi ...

Page 10

... UART The UART provides test and debug access to the LSISAS1064E. Quad Port Module The Quad Port module in the LSISAS1064E implements the SSP, SMP, and STP/SATA protocols, and manages the SAS/SATA phys. The Quad Port module supports four phys. The following subsections describe the Quad Port module ...

Page 11

... The context RAM is a memory that is shared between the host interface module and the quad port module. The context RAM holds a portion of the firmware. LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 Copyright © 2004–2006 by LSI Logic Corporation. All rights reserved. ...

Page 12

... Signal Descriptions The following subsections provide the signal descriptions for the LSISAS1064E. A ‘/’ following the signal indicates an active LOW signal. PCI Express Signals This section describes the PCI Express signals. Refer to the PCI Express specification for detailed signal descriptions. ...

Page 13

... C and UART Signals This section describes the I ISTWI_CLK ISTWI_DATA I UART_RX LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 These pins provide the serial differential clock. Connect a 75 MHz oscillator with an accuracy of at least 50ppm to these pins. To use a single-ended crystal, tie the crystal to REFCLK_P and tie REFCLK_N to a resistor termination ...

Page 14

... ADV/ MAD[31:0] MADP[3:0] MOE[1:0]/ MWE[1:0]/ BWE[3:0 LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 UART Transmit This signal provides the UART transmit signal. Memory Clock All synchronous RAM control/data signals reference the rising edge of this clock. ...

Page 15

... Configuration and General Purpose Signals This section describes the configuration and general purpose pins. TST_RST/ REFCLK_B MODE[7:0] LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 NVSRAM Chip Select Asserting this active LOW signal selects the NVSRAM device ...

Page 16

... TDO TMS TCK_ICE RTCK_ICE TRST_ICE/ TDI_ICE TDO_ICE LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 Fault LED These output signals indicate a SAS link fault. Activity LED These output signals indicate SAS link activity. General Purpose I/O These signals provide general purpose input/output signals ...

Page 17

... VDD2 VDDIO33 VSS RX_VSS[3:0], RXB_VSS[3:0], TX_VSS[3:0], TXB_VSS[3:0] RX_VDD[3:0], RXB_VDD[3:0], TX_VDD[3:0], TXB_VDD[3:0] P_RX_VDD[7:0], P_RXB_VDD[7:0], P_TX_VDD[7:0], LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 Multi-ICE Debug Test Mode Select IDDQ Test Mode Enable This signal is active HIGH. 3-State Output Enable Control This signal is active LOW ...

Page 18

... P_RX_VSS[7:0], P_RXB_VSS[7:0], P_TX_VSS[7:0], Pin Listing Table 1 signal listing by pin name LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 P_TXB_VSS[7:0] These signals provide ground for the PCI Express GigaBlaze core. provides the signal listing by signal name. Figure 4 Copyright © ...

Page 19

... LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 Copyright © 2004–2006 by LSI Logic Corporation. All rights reserved. ...

Page 20

... N/C N/C C24 N/C N/C C25 N/C N/C D3 N/C N/C D23 N/C 1. N/C pins are not connected LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 Pin Signal Pin E1 N/C AC24 E3 N/C AD1 E13 N/C AD3 E22 ...

Page 21

... C26 VDDIO33 VDDIO33 F2 VDDIO33 VDDIO33 F25 VDDIO33 VDDIO33 G2 VDDIO33 VDDIO33 G9 VDDIO33 1. N/C pins are not connected. LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 Pin Signal Pin G11 VDDIO33 AA2 G12 VDDIO33 AA25 G13 VDDIO33 AC23 ...

Page 22

... C24 N/C F24 C25 N/C F25 C26 VDDIO33 F26 D1 MODE[2] G1 ACTIVE_LED[2]/ D2 MODE[ N/C pins are not connected LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 Pin Signal N/C G3 VSS VSS G4 MODE[3] VSS G5 MODE[4] VSS G6 MODE[7] VDD2 ...

Page 23

... N/C AA5 W8 VSS AA6 W9 VSS AA7 P_TX_VSS0 W10 VSS AA8 P_TX_VSS1 1. N/C pins are not connected. LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 Pin Signal VSS AA9 P_RX_VSS1 VSS AA10 P_TXB_VSS2 VSS AA11 P_RXB_VSS2 VSS ...

Page 24

... Figure 4 LSISAS1064E 636 EPBGA-T – Top View (Sheet LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 Copyright © 2004–2006 by LSI Logic Corporation. All rights reserved. ...

Page 25

... Figure 4 LSISAS1064E 636 EPBGA-T – Top View (Sheet LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 Copyright © 2004–2006 by LSI Logic Corporation. All rights reserved. ...

Page 26

... Package Drawing The LSISAS1064E uses a 636 EPBGA-T package. The package code is 8C. Figure LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 provides the package drawing. Copyright © 2004–2006 by LSI Logic Corporation. All rights reserved. ...

Page 27

... This drawing may not be the latest version. For board layout and manufacturing, obtain the most recent engineering drawings from your LSI marketing representative by requesting the outline drawing for package code 8C. LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 ...

Page 28

... LSI marketing representative by requesting the outline drawing for package code 8C LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 Copyright © 2004–2006 by LSI Logic Corporation. All rights reserved. ...

Page 29

... This drawing may not be the latest version. For board layout and manufacturing, obtain the most recent engineering drawings from your LSI marketing representative by requesting the outline drawing for package code 8C. LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller DB08-000275-03 May 2006 - Version 2.0 ...

Page 30

... AP product names may be trademarks of their respective companies. Doc. No. DB08-000275- LSISAS1064E PCI Express to 4-Port Serial Attached SCSI Controller May 2006 Copyright © 2004–2006 by LSI Logic Corporation. All rights reserved. To receive product literature, visit us at http://www.lsilogic.com. http://www.lsilogic.com/contacts/index.html. ISO 9000 Certified ...

Related keywords