Page 1
... Proportional load current sense (with defined fault signal in case of overload operation, overtemperature shutdown and/or short circuit shutdown) Application • Power switch with current sense diagnostic feedback for 12V and grounded loads • All types of resistive, inductive and capacitive loads • Replaces electromechanical relays, fuses and discrete circuits ...
Page 2
... This resistor is also required for reverse operation. See also page 10. Data Sheet Function Output; output to the load; pin 1 and 5 must be externally shorted* . Input; activates the power switch if shorted to ground. Supply Voltage; positive power supply voltage; tab and pin3 are internally shorted. Sense Output; Diagnostic feedback; provides at normal operation a sense current proportional to the load current ...
Page 3
... Thermal Characteristics Parameter and Conditions Thermal resistance junction - ambient (free air): R SMD version, device on PCB Electrical Characteristics Parameter and Conditions 25 unless otherwise specified j bb Load Switching Capabilities and Characteristics On-state resistance (pin 3 to pin 1, 5.5V 7 12V 7 Output voltage drop limitation at small load ...
Page 4
... For operation at voltages higher then |16V| please see required schematic on page 10. 11) Permanent Inverse operation results eventually in a current flow via the intrinsic diode of the power DMOS. In this case the device switches on with a time delay t Data Sheet Symbol T =-40...150 °C: V ...
Page 5
... Short circuit shutdown delay after input current positive slope, V > ON(SC), min. value valid only if input "off-signal" time exceeds 30 µs Short circuit shutdown delay during on condition V > ON(SC) Output clamp (inductive load switch off (e.g. overvoltage) OUT bb ON(CL Thermal overload trip temperature ...
Page 6
Parameter and Conditions 25 unless otherwise specified j bb Diagnostic Characteristics Current sense ratio, static on-condition 16 < ILIS IS,lim V ...
Page 7
... Parameter and Conditions 25 unless otherwise specified j bb Input Required current capability of input switch Input current for turn-off Data Sheet Symbol I IN(on) T =-40..+150° =-40..+150° IN(off PROFET ® BTS 6143 D Values Unit min. typ. max. -- 1.4 2 µA Rev. 1.0, 2007-02 ...
Page 8
Truth Table Normal operation ) 19 Overload ) 20 Short circuit to GND Overtemperature Short circuit to Vbb Open load L = "Low" Level H = "High" Level Terms 3 V bIN PROFET R ...
Page 9
Input circuit (ESD protection Z,IN V bIN ESD-Zener diode typ., max 15 mA; Current sense output Normal operation IS,fault ...
Page 10
... To minimise power dissipation at reverse battery operation, the overall current into the IN and IS pin should be about 80mA. The current can be provided by using a small signal diode D in parallel to the input switch, by using a MOSFET input switch or by proper adjusting the current through R IS. Since the current via R ...
Page 11
... Energy stored in load inductance: While demagnetizing load inductance, the energy dissipated in PROFET is with an approximate solution for R L > 0 Ω: OUT Maximum allowable load inductance for a single switch off j,start = 150° Ω 1000 100 10 30V 1 0 300 [mOhm] 0, PROFET ® BTS 6143 D ...
Page 12
... Data Sheet Figure 2a: Switching motors and lamps OUT dV/dtoff off t slc(IS long as V bIS < V Z,IS the sense current will never exceed I IS,fault and/or I IS,lim . t t soff(IS) Figure 2b: Switching an inductive load OUT PROFET ® BTS 6143 IS,faut IS,lim V ON(CL) Rev. 1.0, 2007- ...
Page 13
... Figure 3a: Typ. current limitation characteristic [A] I L(SC) 100 ON(SC) In case of V > V (typ the device will be ON ON(SC) switched off by internal short circuit detection. Figure 3b: Short circuit type one: shut down by short circuit detection, reset > L(SC) t d(SC1 IS,fault t delay(fault) Shut down remains latched until next reset via input. ...
Page 14
Figure 4b: Overload T < OUT V =1V typ L,lim IS,lim IS,fault k ilis Figure 5a: Undervoltage restart of charge pump, ...
Page 15
Figure 7a: Output voltage drop versus load current [V] 0.1 V 0.05 ON(NL) 0 Data Sheet [ PROFET ® BTS 6143 D ...
Page 16
Package Outlines All dimensions in mm D-Pak-5 Pin: PG-TO252-5-11 Sales Code Green Product To meet the world-wide customer requirements for environmentally friendly products and to be compliant with government regulations the device is available as a green product. Green products ...
Page 17
... Revision History Version Date Changes Rev. 1.0 2007-02-21 RoHS-compliant version of BTS6143D Page 1, page 16: RoHS compliance statement and Green product feature added Page 1, page 16: Change to RoHS compliant package PG-TO252-5-11 Legal disclaimer updated Data Sheet PROFET ® BTS 6143 Rev. 1.0, 2007-02 ...
Page 18
... Infineon Technologies Office. Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies failure of such components can reasonably be expected to cause the failure of that life-support device or system affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body support and/or maintain and sustain and/or protect human life ...