Specifications of 1-215570-6

Rohs Compliant
YES
Product Type
Connector
Type Of Connector
Paddleboard Connector
Mount Angle
Vertical
Pcb Mount Style
Through Hole
Insulation Diameter (mm [in])
0.90 [.035]
Polarization
With
Number Of Positions
16
Wire Range (mm [awg])
0.08-0.09² [28]
Centerline (mm [in])
1.27 [0.050]
Contact Base Material
Phosphor Bronze
Contact Plating, Mating Area, Material
Tin
Housing Color
Red
Housing Material
Polyester GF
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Wave solder capable to 240°C, Wave solder capable to 260°C, Wave solder capable to 265°C
Rohs/elv Compliance History
Always was RoHS compliant
Applies To
Printed Circuit Board
Packaging Method
Reel
Packaging Quantity
2,500
.
QUALITY ASSURANCE PROVISIONS
4.1
4.1.1
Samples shall be released in accordance with applicable instruction sheets. They shall be selected at
random from production. At least 5 connectors of the 6 positions or at least 30 contacts shall be used for
each testgroup.
4.1.2
Qualification inspection shall be verified by testing samples as specified in spec. 108-19052 Par 3.7.
4.2
If changes significantly affecting form, fit or function are made to the product or the manufacturing
process, product assurance shall co-ordinate requalification testing, consisting of all or part of the original
testing sequence as determined by development/product, quality and reliability engineering.
4.3
Acceptance is based on verification that the product meets the requirement of par 3.6. Failures attributed
to equipment, test set-up or operator deficiencies shall nor disqualify the product. When product failure
occurs, corrective action shall be taken and samples resubmitted to qualification. Testing to confirm
corrective action is required before submittal.
4.4
The applicable AMP quality inspection plan will specify the samples acceptable quality level to be used.
Dimensional and functional requirements shall be in accordance with applicable product drawing and this
specification.
Rev. F
R6-77 (Rev. 07-01)
Sample selection:
Test sequence
Qualification testing:
Requalification testing
Acceptance.
Quality Conformance Inspection
Page 15 of 15
108-19052

Related parts for 1-215570-6