S-35390A-T8T1G Seiko Instruments, S-35390A-T8T1G Datasheet - Page 25

IC RTC I2C 2-WIRE 8-TSSOP

S-35390A-T8T1G

Manufacturer Part Number
S-35390A-T8T1G
Description
IC RTC I2C 2-WIRE 8-TSSOP
Manufacturer
Seiko Instruments
Type
Clock/Calendarr
Datasheet

Specifications of S-35390A-T8T1G

Time Format
HH:MM:SS (12/24 hr)
Date Format
YY-MM-DD-dd
Interface
I²C, 2-Wire Serial
Voltage - Supply
1.3 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-TSSOP
Function
Clock/Calendar/Alarm/Battery Backup/Interrupt
Supply Voltage (max)
5.5 V
Supply Voltage (min)
1.3 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Rtc Bus Interface
Serial (2-Wire, I2C)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
728-1007-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S-35390A-T8T1G
Manufacturer:
SEIKO
Quantity:
18 700
Part Number:
S-35390A-T8T1G
Manufacturer:
SEIKO
Quantity:
10 000
Part Number:
S-35390A-T8T1G
Manufacturer:
SEIKO
Quantity:
20 000
Company:
Part Number:
S-35390A-T8T1G
Quantity:
290
Rev.3.0
Function to Clock-Correction
6. Operation of power-on detection circuit (only in the
The function to clock-correction is to correct advance/delay of the clock due to the deviation of oscillation frequency, in
order to make a high precise clock. For correction, the S-35390A adjusts the clock pulse by using a certain part of the
dividing circuit, not adjusting the frequency of the crystal oscillator. Correction is performed once every 20 seconds (or 60
seconds). The minimum resolution is approx. 3 ppm (or approx. 1 ppm) and the S-35390A corrects in the range of − 195.3
to +192.2 ppm (or of − 65.1 to +64.1 ppm).
clock-correction register. Regarding how to calculate the setting data, refer to “1. How to calculate” . When not using this
function, be sure to set “00h”.
• 32kE = 0, INT1AE = INT1ME = 0
Status register 2 setting
When power is applied to the S-35390A, the power-on detection operates to set “1” in the POC flag (B0 in the status
register 1). A 1 Hz clock pulse is output from the
INT1FE
INT1 pin
_00
Correction
Minimum resolution
Correction range
Figure 30 Output Timing of
Table 13 Function to Clock-Correction
− 195.3 to +192.2 ppm
Every 20 seconds
INT
3.052 ppm
Seiko Instruments Inc.
B0 = 0
1
(Refer to Table 13 .) Users can set up this function by using the
Pin during Operation of Power-on Detection Circuit
INT
1
0.5 s
pin.
0.5 s
INT
1
pin output mode)
− 65.1 to +64.1 ppm
Every 60 seconds
2-WIRE REAL-TIME CLOCK
Change by reset command
1.017 ppm
B0 = 1
OFF
S-35390A
25

Related parts for S-35390A-T8T1G