S-35390A-T8T1G Seiko Instruments, S-35390A-T8T1G Datasheet - Page 30

IC RTC I2C 2-WIRE 8-TSSOP

S-35390A-T8T1G

Manufacturer Part Number
S-35390A-T8T1G
Description
IC RTC I2C 2-WIRE 8-TSSOP
Manufacturer
Seiko Instruments
Type
Clock/Calendarr
Datasheet

Specifications of S-35390A-T8T1G

Time Format
HH:MM:SS (12/24 hr)
Date Format
YY-MM-DD-dd
Interface
I²C, 2-Wire Serial
Voltage - Supply
1.3 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-TSSOP
Function
Clock/Calendar/Alarm/Battery Backup/Interrupt
Supply Voltage (max)
5.5 V
Supply Voltage (min)
1.3 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Rtc Bus Interface
Serial (2-Wire, I2C)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
728-1007-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S-35390A-T8T1G
Manufacturer:
SEIKO
Quantity:
18 700
Part Number:
S-35390A-T8T1G
Manufacturer:
SEIKO
Quantity:
10 000
Part Number:
S-35390A-T8T1G
Manufacturer:
SEIKO
Quantity:
20 000
Company:
Part Number:
S-35390A-T8T1G
Quantity:
290
30
2-WIRE REAL-TIME CLOCK
S-35390A
The followings are Read/Write in the S-35390A.
(1) Data Read in S-35390A
After detecting a start condition, the S-35390A receives device code and command. The S-35390A enters the
Read-data mode by the Read/Write bit “1”. The data is output from B7 in 1-byte. Input an acknowledgment signal
from the master device every moment that the S-35390A outputs 1-byte data. However, do not input an
acknowledgment signal (input NO_ACK) for the last data-byte output from the master device. This procedure
notifies the completion of Read. Next, input a stop condition to the S-35390A to finish access.
SDA
SCL
3-byte data
Device code + command
0
1
1
SDA
SCL
1
1-byte data
0
: Input from master device
: Output from S-35390A
0
Figure 34 Example of Data Read 1 (1-Byte Data Register)
Figure 35 Example of Data Read 2 (3-Byte Data Register)
Device code + command
1
: Input from master device
: Output from S-35390A
1
1
0
R/W
1
1
9
B7
1
0
0
Seiko Instruments Inc.
0
0 1
B0
R/W
B7
9
B7
18
Input NO_ACK after the 1st byte
of data has been output.
B0
B0
Input NO_ACK after the 3rd byte of data
has been output.
18
B7
27
B0
36
Rev.3.0
_00

Related parts for S-35390A-T8T1G