M6106/33-057 Leach International, M6106/33-057 Datasheet - Page 7

no-image

M6106/33-057

Manufacturer Part Number
M6106/33-057
Description
Electromechanical Relay SPST-NO 400A 28VDC 60Ohm Stud Mount
Manufacturer
Leach International
Datasheet
Most relay parameters are specified as maximum values over the rated temperature range of the specific relay. Users often
find that key parameters differ significantly at ambient temperature (20-25°C) and sometimes fall into the trap of specifying
their system around these ambient parameters. Additionally the actual temperature experienced by the relay can be far in
excess of existing ambient temperatures due to the heat generated by the coil current and the contact load. Figure 1 is the
summary of temperature effects on relay electrical characteristics.
The following formulas are sometimes useful in calculating the effects shown above.
1. Change in coil resistance due to change of ambient temperature can be calculated by the following formula.
"Rule of Thumb" : For each 10°C change of temperature, coil resistance will change approximately 4%.
2. High and low temperature pick up voltage:
Date of issue: 6/00
Temperature
Increase
Decrease
Application notes
Resistance
UP
DOWN
K
2
= Coefficient of correction found on the graph in Fig. 2 at T
RELAYS AND TEMPERATURE VARIATIONS
Current
DOWN
UP
Where: R = Coil resistance at given temperature
Where: E
E
R
2
T = °C Ambient temperature
1
R = R
20
= Pick Up Voltage at T
= Pick Up Voltage at 20°C
= Coil resistance at 20°C
Operating
Voltage
UP
DOWN
20
E
[1 + .0039 (T-20)]
2
Fig. 1
- 15 -
= E
1
K
2,
Release
Voltage
UP
DOWN
2
temperature
Operate Time
UP
DOWN
2
Release Time
UP
DOWN
N°102
Page 1 of 2

Related parts for M6106/33-057