EP1C4F400C8N Altera, EP1C4F400C8N Datasheet - Page 79

IC CYCLONE FPGA 4K LE 400-FBGA

EP1C4F400C8N

Manufacturer Part Number
EP1C4F400C8N
Description
IC CYCLONE FPGA 4K LE 400-FBGA
Manufacturer
Altera
Series
Cyclone®r
Datasheet

Specifications of EP1C4F400C8N

Number Of Logic Elements/cells
4000
Number Of Labs/clbs
400
Total Ram Bits
78336
Number Of I /o
301
Voltage - Supply
1.425 V ~ 1.575 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
400-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Other names
544-1806
EP1C4F400C8N

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1C4F400C8N
Manufacturer:
CYCLONE
Quantity:
5 510
Part Number:
EP1C4F400C8N
Manufacturer:
ALTERA
Quantity:
104
Part Number:
EP1C4F400C8N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1C4F400C8N
Manufacturer:
ALTERA
Quantity:
6 000
Part Number:
EP1C4F400C8N
Manufacturer:
ALTERA
Quantity:
1 000
Part Number:
EP1C4F400C8N
Manufacturer:
ALTERA
0
Part Number:
EP1C4F400C8N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP1C4F400C8N
Quantity:
56
Part Number:
EP1C4F400C8N
0
Company:
Part Number:
EP1C4F400C8N
Quantity:
6 000
Company:
Part Number:
EP1C4F400C8N
Quantity:
3 000
Part Number:
EP1C4F400C8NAA
Manufacturer:
ALTERA
Quantity:
3 000
Part Number:
EP1C4F400C8NAB
Manufacturer:
ALTERA
Quantity:
3 000
Part Number:
EP1C4F400C8NAC
Manufacturer:
ALTERA
0
Timing Model
Altera Corporation
May 2008
Typically, the user-mode current during device operation is lower than
the power-up current in
Cyclone Power Calculator, available on the Altera web site, to estimate
the user-mode I
regulators based on the higher value.
The DirectDrive technology and MultiTrack interconnect ensure
predictable performance, accurate simulation, and accurate timing
analysis across all Cyclone device densities and speed grades. This
section describes and specifies the performance, internal, external, and
PLL timing specifications.
All specifications are representative of worst-case supply voltage and
junction temperature conditions.
Preliminary and Final Timing
Timing models can have either preliminary or final status. The
Quartus
compilation if the timing models are preliminary.
status of the Cyclone device timing models.
Preliminary status means the timing model is subject to change. Initially,
timing numbers are created using simulation results, process data, and
other known parameters. These tests are used to make the preliminary
numbers as close to the actual timing parameters as possible.
Final timing numbers are based on actual device operation and testing.
These numbers reflect the actual performance of the device under
worst-case voltage and junction temperature conditions.
Table 4–18. Cyclone Device Timing Model Status
®
EP1C12
EP1C20
Device
EP1C3
EP1C4
EP1C6
II software issues an informational message during the design
CCINT
consumption and then select power supplies or
Table
4–17. Altera recommends using the
Preliminary
Table 4–18
Final
v
v
v
v
v
Timing Model
shows the
Preliminary
4–9