Page 1
... SACB-4/ 4-L-C GG Order No.: 1698110 The illustration shows a version with 8 slots http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1698110 Sensor/actuator box header, M12 female connector, Number of slots: 4, Number of positions: 4, Slot assignment: Single, Status indication: Yes, pnp; Master cable connection: Pluggable screw connection, Shielding: No Commercial data GTIN (EAN) ...
Page 2
... SACB-4/ 4-L-C GG Order No.: 1698110 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1698110 Current carrying capacity per slot Total rated current Number of positions Number of slots Degree of protection Inflammability class acc Ambient temperature (operation) Sensor/actuator connection system Local diagnostics function Local diagnostics Master cable data Connection method Tightening torque slot sensor/actuator cable ...
Page 3
... SACB-4/ 4-L-C GG Order No.: 1698110 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1698110 Certificates / Approvals Certification Accessories Item Designation Marking 2809128 ZBN 18:UNBEDRUCKT Protection and sealing elements 1680539 PROT-M12 Tools 1208432 SAC BIT M12-D15 1208445 SACC BIT M12-D20 1206463 SZK PZ2 VDE 1208429 TSD 04 SAC Additional products Item ...
Page 4
... SACB-4/ 4-L-C GG Order No.: 1698110 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1698110 1503014 SACB-C-H180-4/ 4- 5,0PUR 1503027 SACB-C-H180-4/ 4-10,0PUR Diagrams/Drawings Dimensioned drawing Circuit diagram PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Sensor/actuator connector hood, with master cable, marking label, for an SAC box with 4 single-occupied slots Sensor/actuator connector hood, with master cable, marking label, ...
Page 5
... SACB-4/ 4-L-C GG Order No.: 1698110 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1698110 Schematic diagram M12 slot, socket, 4-pos. PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Potential U and U bridged N1 N2 Page Jun 2, 2011 ...
Page 6
... SACB-4/ 4-L-C GG Order No.: 1698110 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1698110 PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Electrically isolated Page Jun 2, 2011 ...
Page 7
... SACB-4/ 4-L-C GG Order No.: 1698110 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1698110 Address PHOENIX CONTACT Inc., USA 586 Fulling Mill Road Middletown, PA 17057,USA Phone (800) 888-7388 Fax (717) 944-1625 http://www.phoenixcon.com © 2011 Phoenix Contact Technical modifications reserved; PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page Jun 2, 2011 ...