EP3C55F484I7 Altera, EP3C55F484I7 Datasheet - Page 3

IC CYCLONE III FPGA 55K 484 FBGA

EP3C55F484I7

Manufacturer Part Number
EP3C55F484I7
Description
IC CYCLONE III FPGA 55K 484 FBGA
Manufacturer
Altera
Series
Cyclone® IIIr

Specifications of EP3C55F484I7

Number Of Logic Elements/cells
55856
Number Of Labs/clbs
3491
Total Ram Bits
2396160
Number Of I /o
327
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
484-FBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP3C55F484I7
Manufacturer:
TI
Quantity:
2 847
Part Number:
EP3C55F484I7
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP3C55F484I7
Manufacturer:
Altera
Quantity:
10
Part Number:
EP3C55F484I7
Manufacturer:
ALTERA
0
Part Number:
EP3C55F484I7N
Manufacturer:
FREESCALE
Quantity:
1 445
Part Number:
EP3C55F484I7N
Manufacturer:
ALTERA
Quantity:
118
Part Number:
EP3C55F484I7N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP3C55F484I7N
Manufacturer:
XILINX
0
Part Number:
EP3C55F484I7N
Manufacturer:
ALTERA
Quantity:
80
Part Number:
EP3C55F484I7N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP3C55F484I7N
0
Chapter 1: Cyclone III Device Data Sheet
Electrical Characteristics
© January 2010 Altera Corporation
Table 1–2. Cyclone III Devices Maximum Allowed Overshoot During Transitions over a 10-Year Time
Frame
Note to
(1)
Symbol
V
Figure 1–1
voltage is shown in red and is present on the input pin of the Cyclone III device at over 4.1 V but below 4.2 V. From
Table
a 10-year period. Percentage of high time is calculated as ([delta T]/T) × 100. This 10-year period assumes the
device is always turned on with 100% I/O toggle rate and 50% duty cycle signal. For lower I/O toggle rates and
situations in which the device is in an idle state, lifetimes are increased.
i
Table
(Note 1)
1–1, for an overshoot of 4.1 V, the percentage of high time for the overshoot can be as high as 31.97% over
1–2:
Parameter
shows the methodology to determine the overshoot duration. In the example in
AC Input
Voltage
V
V
V
V
V
V
V
V
V
V
V
V
V
Condition
V
I
I
I
I
I
I
I
I
I
I
I
I
I
I
= 3.95 V
= 4.05 V
= 4.10 V
= 4.15 V
= 4.20 V
= 4.25 V
= 4.30 V
= 4.35 V
= 4.40 V
= 4.45 V
= 4.50 V
= 4.60 V
= 4.70 V
= 4.0 V
Overshoot Duration as % of High Time
95.67
55.24
31.97
18.52
10.74
0.047
Cyclone III Device Handbook, Volume 2
6.23
3.62
1.22
0.71
0.41
0.14
100
2.1
Figure
1–1, overshoot
Unit
%
%
%
%
%
%
%
%
%
%
%
%
%
%
1–3