EP2S90F1508I4 Altera, EP2S90F1508I4 Datasheet - Page 92

IC STRATIX II FPGA 90K 1508-FBGA

EP2S90F1508I4

Manufacturer Part Number
EP2S90F1508I4
Description
IC STRATIX II FPGA 90K 1508-FBGA
Manufacturer
Altera
Series
Stratix® IIr
Datasheet

Specifications of EP2S90F1508I4

Number Of Logic Elements/cells
90960
Number Of Labs/clbs
4548
Total Ram Bits
4520488
Number Of I /o
902
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
1508-FBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-
Other names
544-1923
EP2S90F1508I4

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2S90F1508I4
Manufacturer:
ALTERA
Quantity:
3 000
Part Number:
EP2S90F1508I4
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2S90F1508I4
Manufacturer:
ALTERA
0
Part Number:
EP2S90F1508I4N
Manufacturer:
ALTERA
Quantity:
586
Part Number:
EP2S90F1508I4N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2S90F1508I4N
Manufacturer:
ALTERA
0
Company:
Part Number:
EP2S90F1508I4N
Quantity:
100
I/O Structure
2–84
Stratix II Device Handbook, Volume 1
Table 2–15
strength control.
Open-Drain Output
Stratix II devices provide an optional open-drain (equivalent to an open-
collector) output for each I/O pin. This open-drain output enables the
device to provide system-level control signals (e.g., interrupt and write-
enable signals) that can be asserted by any of several devices.
Bus Hold
Each Stratix II device I/O pin provides an optional bus-hold feature. The
bus-hold circuitry can weakly hold the signal on an I/O pin at its
last-driven state. Since the bus-hold feature holds the last-driven state of
the pin until the next input signal is present, you do not need an external
pull-up or pull-down resistor to hold a signal level when the bus is
tri-stated.
Note to
(1)
3.3-V LVTTL
3.3-V LVCMOS
2.5-V LVTTL/LVCMOS
1.8-V LVTTL/LVCMOS
1.5-V LVCMOS
SSTL-2 Class I
SSTL-2 Class II
SSTL-18 Class I
SSTL-18 Class II
HSTL-18 Class I
HSTL-18 Class II
HSTL-15 Class I
HSTL-15 Class II
Table 2–15. Programmable Drive Strength
The Quartus II software default current setting is the maximum setting for each
I/O standard.
I/O Standard
Table
shows the possible settings for the I/O standards with drive
2–15:
I
Setting (mA) for Column
OH
24, 20, 16, 12, 8, 4
24, 20, 16, 12, 8, 4
/ I
12, 10, 8, 6, 4, 2
OL
12, 10, 8, 6, 4
12, 10, 8, 6, 4
12, 10, 8, 6, 4
20, 18, 16, 8
16, 12, 8, 4
20, 18, 16
20, 18, 16
24, 20, 16
Current Strength
8, 6, 4, 2
I/O Pins
12, 8
Note (1)
I
Setting (mA) for Row I/O
OH
/ I
OL
12, 10, 8, 6, 4
Altera Corporation
10, 8, 6, 4
Current Strength
8, 6, 4, 2
12, 8, 4
12, 8, 4
8, 6, 4
12, 8
Pins
8, 4
4, 2
16
-
-
-
May 2007

Related parts for EP2S90F1508I4