G6W-1F-DC24 Omron, G6W-1F-DC24 Datasheet - Page 2

no-image

G6W-1F-DC24

Manufacturer Part Number
G6W-1F-DC24
Description
RF (Radio Frequency) Relays 5.0 GHz SPDT 24VDC
Manufacturer
Omron
Series
G6Wr
Datasheet

Specifications of G6W-1F-DC24

Contact Form
1 Form C
Coil Voltage
24 VDC
Coil Type
Non-Latching
Power Consumption
200 mW
Termination Style
Solder Terminal
Coil Current
8.3 mA
Coil Resistance
2880 Ohms
Contact Rating
10 mA at 30 VAC
Frequency
5 GHz
Current, Rating
10 mA
Function
Frequency (RF)
Mounting Type
PCB
Number Of Pins
20
Power, Rating
10 W
Relay Type
Electro Mechanical
Standards
RoHS
Termination
Surface Mount
Voltage, Control
24 VDC
Voltage, Rating
30 VAC/VDC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
24DC G6W-1F

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G6W-1F-DC24V
Manufacturer:
OMRON
Quantity:
12 000
Specifications
■ Contact Ratings
■ High-frequency Characteristics
Note: 1. The above values are initial values.
■ Coil Ratings
Non-latching Relays (G6W-1F, G6W-1P)
Single-coil Latching Relays (G6WU-1F, G6WU-1P)
Dual-coil Latching Relays (G6WK-1F, G6WK-1P)
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ± 10%.
328
Load type
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Frequency
Isolation
Insertion loss
V.S.W.R.
Max. carry power
Max. switching power
Rated voltage
Rated current
Coil resistance
Must operate voltage
Must release voltage
Maximum voltage
Power consumption
Rated voltage
Rated current
Coil resistance
Must set voltage
Must reset voltage
Maximum voltage
Power consumption
Rated voltage
Rated current
Coil resistance
Must set voltage
Must reset voltage
Maximum voltage
Power consumption
2. These values are for a load with V.S.W.R. ≤1.2 at an impedance of 50 Ω.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
4. The voltage measurements for operate/release and set/reset are the values obtained for instantaneous changes in the voltage.
(Rectangular wave).
High-frequency Relay
G6W
DISCONTINUED
3 VDC
120 mA
25 Ω
80% max. of rated voltage
80% max. of rated voltage
150% of rated voltage
Approx. 360 mW
9 VDC
22.2 mA
405 Ω
80% max. of rated voltage
80% max of rated voltage
150% of rated voltage
Approx. 200 mW
3 VDC
66.7 mA
45 Ω
80% of max. of rated voltage
10% min. of rated voltage
150% of rated voltage
Approx. 200 mW
65 dB min.
0.2 dB max.
1.2 max.
20 W (See note 2)
10 W (See note 2)
Resistive load
Au clad Cu alloy
10 mA at 30 VAC; 10 mA at 30 VDC
2.5 GHz, 50 Ω, 10 W (See note 2)
0.5 A
30 VDC, 30 VAC
0.5 A
2.0 GHz
4.5 VDC
80 mA
56 Ω
4.5 VDC
44.4 mA
101 Ω
60 dB min.
9 VDC
40 mA
225 Ω
2.5 GHz
9 VDC
22.2 mA
405 Ω
12 VDC
16.7 mA
720 Ω
12 VDC
30 mA
400 Ω
35 dB min.
0.5 dB max.
1.7 max.
12 VDC
16.7 mA
720 Ω
5.0 GHz
24 VDC
15 mA
1,600 Ω
24 VDC
8.3 mA
2,880 Ω

Related parts for G6W-1F-DC24