ISP1362BDFA ST-Ericsson Inc, ISP1362BDFA Datasheet - Page 44

IC USB OTG CONTROLLER 64-LQFP

ISP1362BDFA

Manufacturer Part Number
ISP1362BDFA
Description
IC USB OTG CONTROLLER 64-LQFP
Manufacturer
ST-Ericsson Inc
Datasheet

Specifications of ISP1362BDFA

Controller Type
USB 2.0 Controller
Interface
Parallel/Serial
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
64-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Supply
-
Other names
568-1219
ISP1362BD,151
ISP1362BD-S

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ISP1362BDFA
Manufacturer:
STE
Quantity:
5
Part Number:
ISP1362BDFA
Manufacturer:
ST-Ericsson Inc
Quantity:
10 000
NXP Semiconductors
Table 11.
ISP1362_5
Product data sheet
Name
ActualBytes[9:0]
CompletionCode[3:0]
Active
Toggle
MaxPktSize[9:0]
EndpointNumber[3:0]
Generic PTD structure: bit description
Status update
by HC
Yes
Yes
Yes
Yes
No
No
Description
This field contains the number of bytes that were transferred for this PTD.
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
Set to logic 1 by firmware to enable the execution of transactions by the Host
Controller. When the transaction associated with this descriptor is completed,
the Host Controller sets this bit to logic 0, indicating that a transaction for this
element should not be executed when it is next encountered in the schedule.
This bit is used to generate or compare the data PID value (DATA0 or DATA1)
for IN and OUT transactions. It is updated after each successful transmission
or reception of a data packet.
This indicates the maximum number of bytes that can be sent to or received
from the endpoint in a single data packet.
This is the USB address of the endpoint within the function.
Rev. 05 — 8 May 2007
NoError
CRC
BitStuffing
DataToggleMismatch
Stall
DeviceNot
Responding
PIDCheckFailure
UnexpectedPID
DataOverrun
DataUnderrun
-
-
BufferOverrun
BufferUnderrun
General Transfer Descriptor (TD) or
isochronous data packet processing
completed with no detected errors.
The last data packet from the endpoint
contained a Cyclic Redundancy Check
(CRC) error.
The last data packet from the endpoint
contained a bit stuffing violation.
The last packet from the endpoint had data
toggle Packet ID (PID) that did not match the
expected value.
TD was moved to the Done queue because
the endpoint returned a STALL PID.
The device did not respond to the token (IN)
or did not provide a handshake (OUT).
The check bits on PID from the endpoint
failed on data PID (IN) or handshake (OUT).
The received PID was not valid when
encountered, or the PID value is not defined.
The amount of data returned by the endpoint
exceeded either the size of the maximum
data packet allowed from the endpoint (found
in the MaxPacketSize field of ED) or the
remaining buffer size.
The endpoint returned is less than
MaxPacketSize and that amount was not
sufficient to fill the specified buffer.
reserved
reserved
During an IN, the Host Controller received
data from the endpoint faster than it could be
written to the system memory.
During an OUT, the Host Controller could not
retrieve data from the system memory fast
enough to keep up with the USB data rate.
Single-chip USB OTG Controller
© NXP B.V. 2007. All rights reserved.
ISP1362
43 of 152

Related parts for ISP1362BDFA