CP2201-GM Silicon Laboratories Inc, CP2201-GM Datasheet - Page 83

IC ETH CTRLR SNGL-CHIP 28QFN

CP2201-GM

Manufacturer Part Number
CP2201-GM
Description
IC ETH CTRLR SNGL-CHIP 28QFN
Manufacturer
Silicon Laboratories Inc
Datasheets

Specifications of CP2201-GM

Package / Case
48-TQFP, 48-VQFP
Controller Type
Ethernet Controller, MAC/10Base-T
Interface
Parallel/Serial
Voltage - Supply
3.1 V ~ 3.6 V
Current - Supply
75mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Ethernet Connection Type
1000BASE-T or 100BASE-T or 10BASE-T
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Product
Ethernet Controllers
Standard Supported
IEEE 802.3
Data Rate
10 Mbps or 100 Mbps or 1000 Mbps
Maximum Operating Temperature
+ 85 C
No. Of Ports
1
Ethernet Type
IEEE 802.3
Interface Type
Parallel
Supply Current
60mA
Supply Voltage Range
3.1V To 3.6V
Operating Temperature Range
-40°C To +85°C
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
336-1326 - KIT REF DESIGN PWR OVER ETHERNET336-1316 - KIT EVAL FOR CP2201 ETH CTRLR
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1313

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CP2201-GM
Manufacturer:
SiliconL
Quantity:
48
Part Number:
CP2201-GMR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Bit 3:
Bit 2:
Bit 1:
Bit 0:
PADMD1[7] PADMD0[6] PADEN[5] CRCEN[4]
PHEADER: Proprietary Header Select Bit
0: No proprietary header exists on the front of IEEE 802.3 frames.
1: Four bytes of proprietary header information exist on the front of IEEE 802.3 frames. These bytes
will be ignored by the CRC function.
Reserved. Read = 0b; Must write 0b.
LENCHK: Frame Length Checking Enable Bit
0: Frame length checking is disabled.
1: Transmit and receive frame lengths are compared to the Length/Type field. If the Length/Type
field represents a length then the check is performed. Mismatches are reported in the Transmit/
Receive status vectors.
FLLDPLX: Full-Duplex Mode Enable Bit
0: MAC operates in half-duplex mode.
1: MAC operates in full-duplex mode.
Indirect Register 2. MACCF: MAC Configuration Register (Continued)
x
x
0
x
1
x
x
0
1
0
0
0
1
1
1
Table 21. Pad Operation
0
1
1
1
1
Rev. 1.0
No padding added on transmitted packets,
check CRC
No padding added on transmitted packets,
append CRC
Pad short frames to 60 bytes, append CRC
Pad short frames to 64 bytes, append CRC
Auto Detect Tagged VLAN Frames
(IEEE802.1q)
If untagged: Pad to 60 bytes, append CRC
If tagged: Pad to 64 bytes, append CRC
Action
CP2200/1
83