PKM4204BPI Ericsson Power Modules, PKM4204BPI Datasheet

DC/DC Converters & Regulators 12 Vdc 25A Iso Input 36-75V 290W

PKM4204BPI

Manufacturer Part Number
PKM4204BPI
Description
DC/DC Converters & Regulators 12 Vdc 25A Iso Input 36-75V 290W
Manufacturer
Ericsson Power Modules
Series
PKM-Br
Datasheet

Specifications of PKM4204BPI

Product
Isolated
Output Power
30 W
Input Voltage Range
36 V to 75 V
Number Of Outputs
1
Output Voltage (channel 1)
1.5 V
Output Current (channel 1)
20 A
Isolation Voltage
1.5 KV
Package / Case Size
Quarter Brick
Output Type
Isolated Bus Converters
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PKM4204BPI
Manufacturer:
Ericsson
Quantity:
100
Part Number:
PKM4204BPI
Manufacturer:
ERICSSON/爱立信
Quantity:
20 000
Part Number:
PKM4204BPIHS
Manufacturer:
ERICSSON/爱立信
Quantity:
20 000
Part Number:
PKM4204BPIHSGLA
Manufacturer:
ERICSSON/爱立信
Quantity:
20 000
Part Number:
PKM4204BPIHSLA
Manufacturer:
ERICSSON/爱立信
Quantity:
20 000
Part Number:
PKM4204BPIHSLB
Manufacturer:
ERICSSON/爱立信
Quantity:
20 000
Part Number:
PKM4204BPILPLC
Manufacturer:
ROHM
Quantity:
10 000
E
Contents
Ordering Information
General Information
Safety Specification
Absolute Maximum Ratings
12V, 25A / 290W
12V, 33A / 380W
12.45V, 33A / 400W
EMC Specification
Operating Information
Thermal Consideration
Connections
Mechanical Information
Soldering Information
Delivery Information
Product Qualification Specification
Prepared (also subject responsible if other)
Prepared (also subject responsible if other)
SEC/S Marshall Wang
SEC/S Marshall Wang
Approved
Approved
PKM4000B series Intermediate Bus Converters
Input 36-75 V, Output up to 33 A / 400 W
Key Features
• Industry standard Quarter-brick
• High efficiency, typ. 96 % at 12 Vout 50% load & 48Vin
• 1500 Vdc input to output isolation
• Meets safety requirements according to IEC/EN/UL
General Characteristics
• N+1 parallelable
• Input under voltage protection
• Over temperature protection
• Output over voltage protection
• Remote control
• SMD option with low profile 11.2mm
• Highly automated manufacturing ensures quality
• ISO 9001/14001 certified supplier
Electrical Specification
57.9 x 36.8 x 11.6 mm (2.28 x 1.45 x 0.46 in.)
60950
More than 1.1 million hours MTBF
Output short-circuit protection
Optional latching OTP, OVP
Optional baseplate
Optional case to ground pin (only with baseplate)
Checked
Checked
Ericsson Internal
Ericsson Internal
PRODUCT SPECIFICATION
TABLE OF CONTENTS
No.
No.
001 52-EN/LZT 146 305 Uen
Date
Date
2010-06-02
2010-12-09
Safety Approvals
E210157
PKM4204B PI ....................................... 5
PKM4304B .......................................... 9
PKM4304B OA .................................. 13
............................................................. 2
............................................................. 2
............................................................. 3
............................................................. 4
........................................................... 16
........................................................... 17
........................................................... 19
........................................................... 20
........................................................... 21
........................................................... 24
........................................................... 25
........................................................... 27
Technical Specification
EN/LZT 146 305 R6E January 2011
© Ericsson AB
Rev
Rev
K
K
Reference
Reference
T
Design for Environment
Meets requirements in high-
temperature lead-free soldering
processes.
1 (4)
1 (1)

Related parts for PKM4204BPI

PKM4204BPI Summary of contents

Page 1

E Prepared (also subject responsible if other) Prepared (also subject responsible if other) SEC/S Marshall Wang SEC/S Marshall Wang Approved Approved PKM4000B series Intermediate Bus Converters Input 36-75 V, Output 400 W Key Features • ...

Page 2

... Warranty Warranty period and conditions are defined in Ericsson Power Modules General Terms and Conditions of Sale. Limitation of Liability Ericsson Power Modules does not make any other warranties, expressed or implied including any warranty merchantability or fitness for a particular purpose ...

Page 3

... ETS300132-2 “Power supply interface at the input to telecommunications equipment; part 2: DC”, but all of these standards are based on IEC/EN/UL60950 with regards to safety. Ericsson Power Modules DC/DC converters and DC/DC regulators are UL60950 recognized and certified in accordance with EN60950. The flammability rating for all construction parts of the products meets requirements for V-0 class material according to IEC 60695-11-10 ...

Page 4

E Prepared (also subject responsible if other) SECSUND Approved PKM4000B series Intermediate Bus Converters SEC/D (Julia You) Input 36-75 V, Output 400 W Absolute Maximum Ratings Characteristics T Operating Temperature (see Thermal Consideration section) ref ...

Page 5

E Prepared (also subject responsible if other) SECSUND Approved PKM4000B series Intermediate Bus Converters SEC/D (Julia You) Input 36-75 V, Output 400 W 12 V/25 A Electrical Specification T = -40 to +90º C for ...

Page 6

E Prepared (also subject responsible if other) SECSUND Approved PKM4000B series Intermediate Bus Converters SEC/D (Julia You) Input 36-75 V, Output 400 W 12 V/25 A Typical Characteristics Efficiency [%] 100 ...

Page 7

E Prepared (also subject responsible if other) SECSUND Approved PKM4000B series Intermediate Bus Converters SEC/D (Julia You) Input 36-75 V, Output 400 W 12 V/25 A Typical Characteristics Output Current Derating, open frame [A] 25 ...

Page 8

E Prepared (also subject responsible if other) SECSUND Approved PKM4000B series Intermediate Bus Converters SEC/D (Julia You) Input 36-75 V, Output 400 W 12 V/25 A Typical Characteristics Start-up Place your graph here Start-up enabled ...

Page 9

E Prepared (also subject responsible if other) SECSUND Approved PKM4000B series Intermediate Bus Converters SEC/D (Julia You) Input 36-75 V, Output 400 W 12 V/33 A Electrical Specification T = -40 to +90ºC for open ...

Page 10

E Prepared (also subject responsible if other) SECSUND Approved PKM4000B series Intermediate Bus Converters SEC/D (Julia You) Input 36-75 V, Output 400 W 12 V/33 A Typical Characteristics Efficiency [%] 100 ...

Page 11

E Prepared (also subject responsible if other) SECSUND Approved PKM4000B series Intermediate Bus Converters SEC/D (Julia You) Input 36-75 V, Output 400 W 12 V/33 A Typical Characteristics Output Current Derating, open frame [A] 30 ...

Page 12

E Prepared (also subject responsible if other) SECSUND Approved PKM4000B series Intermediate Bus Converters SEC/D (Julia You) Input 36-75 V, Output 400 W 12 V/33 A Typical Characteristics Start-up Place your graph here Start-up enabled ...

Page 13

E Prepared (also subject responsible if other) SECSUND Approved PKM4000B series Intermediate Bus Converters SEC/D (Julia You) Input 36-75 V, Output 400 W 12.45 V/33 A Electrical Specification T = -40 to +60º ...

Page 14

E Prepared (also subject responsible if other) SECSUND Approved PKM4000B series Intermediate Bus Converters SEC/D (Julia You) Input 36-75 V, Output 400 W 12.45 V/33 A Typical Characteristics Efficiency [%] ...

Page 15

E Prepared (also subject responsible if other) SECSUND Approved PKM4000B series Intermediate Bus Converters SEC/D (Julia You) Input 36-75 V, Output 400 W 12.45 V/33 A Typical Characteristics Start-up Place your graph here Start-up enabled ...

Page 16

E Prepared (also subject responsible if other) EXUEFYA Approved PKM4000B series Intermediate Bus Converters SEC/D (Julia You) Input 36-75 V, Output 400 W EMC Specification Conducted EMI measured according to EN55022, CISPR 22 and FCC ...

Page 17

E Prepared (also subject responsible if other) EXUEFYA Approved PKM4000B series Intermediate Bus Converters SEC/D (Julia You) Input 36-75 V, Output 400 W Operating information Input Voltage The input voltage range Vdc ...

Page 18

E Prepared (also subject responsible if other) EXUEFYA Approved PKM4000B series Intermediate Bus Converters SEC/D (Julia You) Input 36-75 V, Output 400 W Over Temperature Protection (OTP) The DC/DC converters are protected from thermal overload ...

Page 19

E Prepared (also subject responsible if other) EXUEFYA Approved PKM4000B series Intermediate Bus Converters SEC/D (Julia You) Input 36-75 V, Output 400 W Thermal Consideration General The product is designed to operate in various thermal ...

Page 20

E Prepared (also subject responsible if other) EXUEFYA Approved PKM4000B series Intermediate Bus Converters SEC/D (Julia You) Input 36-75 V, Output 400 W Connections Pin Designation Function 1 +In Positive input 2 RC Remote control ...

Page 21

E Prepared (also subject responsible if other) MICUPEZ/EPETSCH Approved PKM4000B series Intermediate Bus Converters SEC/D [Julia You] Input 36-75 V, Output 400 W Mechanical Information — Through hole mount version Ericsson Internal PRODUCT SPECIFICATION No. ...

Page 22

E Prepared (also subject responsible if other) MICUPEZ/EPETSCH Approved PKM4000B series Intermediate Bus Converters SEC/D [Julia You] Input 36-75 V, Output 400 W Mechanical Information- Base plate Ericsson Internal PRODUCT SPECIFICATION No. Technical Specification 4/1301-BMR ...

Page 23

E Prepared (also subject responsible if other) MICUPEZ/EPETSCH Approved PKM4000B series Intermediate Bus Converters SEC/D [Julia You] Input 36-75 V, Output 400 W Mechanical information — SMD version Ericsson Internal PRODUCT SPECIFICATION No. Technical Specification ...

Page 24

E Prepared (also subject responsible if other) MICUPEZ/EPETSCH Approved PKM4000B series Intermediate Bus Converters EAB/FJB/GMF [Julia You] Input 36-75 V, Output 400 W Soldering Information – Surface Mounting The surface mount product is intended for ...

Page 25

E Prepared (also subject responsible if other) MICUPEZ/EPETSCH Approved PKM4000B series Intermediate Bus Converters EAB/FJB/GMF [Julia You] Input 36-75 V, Output 400 W Delivery Package Information – Surface Mount Version The products are delivered in ...

Page 26

E Prepared (also subject responsible if other) MICUPEZ/EPETSCH Approved PKM4000B series Intermediate Bus Converters EAB/FJB/GMF [Julia You] Input 36-75 V, Output 400 W Soldering Information - Hole Mounting The hole mounted product is intended for ...

Page 27

E Prepared (also subject responsible if other) MICUPEZ/EPETSCH Approved PKM4000B series Intermediate Bus Converters EAB/FJB/GMF [Julia You] Input 36-75 V, Output 400 W Product Qualification Specification Characteristics External visual inspection IPC-A-610 Change of temperature IEC ...

Related keywords