AT-FM-10K BANNER ENGINEERING, AT-FM-10K Datasheet - Page 12

no-image

AT-FM-10K

Manufacturer Part Number
AT-FM-10K
Description
Control Module, Two Hand; Solid State (NPN, PNP), Relay (Auxiliary N.C.); 200 W
Manufacturer
BANNER ENGINEERING
Type
Safetyr
Datasheets

Specifications of AT-FM-10K

Brand/series
Duo-Touch
Contact Form
SPDT-NO/NC
Dimensions
22.5mmW×84mmH×118mmD
Enclosure Rating
IP20
Indicator
4 Green LED, 1 Red LED
Ip Rating
IP20
Material, Casing
Polycarbonate
Mounting
DIN Rail
Mounting Type
DIN Rail
Number Of Outputs
4
Output Type
Digital/Relay
Power Consumption
200 W
Primary Type
Controller
Standards
cULus, cCSAus, CE
Temperature, Operating
0 to +50 °C
Voltage, Supply
24 VDC
Coil Voltage Vac Nom
24V
Coil Voltage Vdc Nom
24V
Contact Current Max
6A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
24V
Contact Configuration
SPST-NO
No. Of Poles
1
Lead Free Status / Rohs Status
RoHS Exempt Product
For Use With
Two-Hand Control
12
Supply
Supply Protection Circuitry
Overvoltage Category
Pollution Degree
Output Configuration
Output Response Time
Input Requirements
24V dc ±15% @ 150 mA (use a SELV-rated supply according to EN IEC 60950, NEC Class 2)
24V ac ±15% @ 150 mA, 50-60 Hz +/- 5% (use an NEC Class 2-rated transformer)
To comply with UL and CSA standards, the installation’s isolated secondary power supply circuit must incorporate a method
to limit the overvoltage to 0.8 kV.
Protected against transient voltages and reverse polarity
Output relay contact voltage of 1V to 150V ac/dc: Category III
Output relay contact voltage of 151V to 250V ac/dc: Category II (Category III, if appropriate overvoltage reduction is
provided, as described in this document.)
2
Each normally open output channel is a series connection of contacts from two forced-guided (mechanically linked) relays,
K1-K2.
Contacts: AgNi, 5 µm gold-plated
Low Current Rating: The 5 µm gold-plated contacts allow the switching of low current/low voltage. In these low-power
applications, multiple contacts can also be switched in series (e.g., “dry switching”). To preserve the gold plating on the
contacts, do not exceed the following max. values at any time:
High Current Rating: If higher loads must be switched through one or more of the contacts, the minimum and maximum
values of the contact(s) changes to:
Mechanical life: 20,000,000 operations
Electrical life (switching cycles of the output contacts, resistive load): 150,000 cycles @ 900 VA; 1,000,000 cycles @
250 VA; 2,000,000 cycles @ 150 VA; 5,000,000 cycles @ 100 VA
35 milliseconds maximum
Outputs from actuating devices must each be capable of switching 25 mA @ 24V dc (nominal).
Min. voltage: 1V ac/dc
Min. current: 5 mA ac/dc
Min. power: 5 mW (5 mVA)
Voltage:
Current:
Power:
Voltage:
Current:
Power:
www.bannerengineering.com - tel: 763-544-3164
Minimum:
15V ac/dc
30 mA ac/dc
0.45 W (0.45 VA)
15V ac/dc
30 mA ac/dc
0.45 W (0.45 VA)
Specifications
Max. voltage: 60V
Max. current: 300 mA
Max. power: 7 W (7 VA)
Maximum:
250V ac / 24V dc, 6 A resistive
250V ac / 24V dc, 6 A resistive
IEC 60947-5-1; AC15: 230V ac, 3 A;
DC-13: 24V dc, 2 A
——
——
——
AT-FM-10K Two-Hand Control Module
P/N 64137 F

Related parts for AT-FM-10K